S11 · Lesson 41 · Soft switching
The capacitive turn-on loss that hard switching can't avoid, zero-voltage switching by letting current swing the node during the dead time, the energy and time it takes, zero-current switching for IGBTs, the phase-shifted full bridge and its duty-cycle loss
Lesson 8 found two kinds of switching loss: the overlap of voltage and current during a transition, and the energy stored in the transistor's output capacitance, which a hard turn-on dumps into the channel as heat. Faster transistors shrink the first but not the second; at 400 V and a few hundred kilohertz, the capacitive part alone can cost watts per device. Soft switching removes it by arranging for some current to swing the switch node during the dead time, so each transistor turns on with no voltage across it.
- The voltage across a MOSFET during the dead time before it turns on, in a leg with 200 pF of output capacitance per switch on a 400 V bus. An inductor carrying current I at the start of the dead time rings with the two capacitances, pulling the node down.
- If the inductor's energy is enough (), the voltage reaches zero and the body diode clamps it there: zero-voltage switching. If not, the switch turns on with voltage left and dumps the rest.
- With L = 16 µH, 2 A is exactly enough.
Predict
A half-bridge leg switches 400 V at 200 kHz, and each MOSFET has 200 pF of output capacitance. How much power does hard turn-on waste in the capacitances alone?
Each hard turn-on discharges that switch's own through its channel, dissipating = 16 µJ, and the turn-on also charges the opposite switch's capacitance through it. At 200 kHz the first part alone is 16 µJ × 200 kHz = 3.2 W per switch, regardless of how fast the gate is driven.
Name it
Hard switching
At hard turn-on, the energy stored in the switch's output capacitance is dissipated in its channel, costing per switch. (For superjunction MOSFETs is strongly nonlinear; use the datasheet's in place of .)
Zero-voltage switching (ZVS)
During the dead time, a current I flowing out of the switch node charges the upper switch's capacitance and discharges the lower one's (or the reverse). If the node reaches the opposite rail, the incoming switch's body diode conducts and the switch turns on at zero voltage: no capacitive loss and no overlap loss.
- With a large inductor whose current stays nearly constant, the transition takes , which must fit in the dead time.
- With the inductor as the only energy source, its energy must cover both capacitances: , so or . The resonant swing takes at most a quarter period, .
Converters get the needed current from a resonant tank (lesson 40), from a deliberately large ripple that makes the inductor current go negative each cycle (triangular current mode), or from transformer leakage.
Zero-current switching (ZCS)
A resonant circuit brings the switch's current to zero before turn-off. It suits IGBTs and thyristors, whose turn-off tail current makes turn-off their dominant loss, but it doesn't remove the capacitive turn-on loss, so MOSFET designs prefer ZVS.
The phase-shifted full bridge
Two legs at fixed 50% duty cycle, shifted in phase to set the effective duty cycle; transformer leakage swings the switch nodes for ZVS. While the primary current reverses from to through , no power transfers, losing a duty cycle of
Worked example
Can a synchronous buck reach ZVS at 400 V with 200 pF switches and a 10 µH inductor?
Show the solution
- Current needed for ZVS. flowing backward through the inductor at the moment the low-side switch turns off.
- How to get it. A triangular-current-mode design sizes the ripple so the current swings at least that far negative every cycle.
- Transition time. Once the current flows, the transition with a steady 2 A (taking the inductor as a current source) lasts so the dead time must be at least that.
Answer yes, if at least 2.53 A flows backward through the inductor when the low-side switch turns off.
Worked example
A phase-shifted full bridge on 400 V at 100 kHz has 5 µH of leakage and 5 A of primary current. What duty cycle does it lose?
Show the solution
- Reversal time. during which the secondary sees no voltage.
- Duty cycle lost. Over each 5 µs half period that's
- The trade-off. More leakage helps ZVS at light load but costs duty cycle at full load, so designers often add a separate resonant inductor and size it for the lightest load that must stay soft.
Answer it loses 0.025 of duty cycle, 125 ns in each half period.
Worked example
An LLC half bridge on 400 V reflects 200 V across a 200 µH magnetizing inductance at 100 kHz. Its switches have 300 pF each. Can the magnetizing current alone give ZVS, and how long a dead time is needed?
Show the solution
- Magnetizing current. at each transition, independent of load.
- Transition time. Swinging the node across 400 V with 2 × 300 pF takes
- Dead time. A dead time of about 100 ns or more gives ZVS from no load to full load, one of the LLC's main attractions.
Answer yes: the 2.5 A of magnetizing current swings the node in 96 ns, so a dead time of about 100 ns or more gives ZVS at every load.
Check
A MOSFET with 300 pF of output capacitance switches 48 V at 1000 kHz, hard. What does its capacitance cost at turn-on?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A leg has 250 pF per switch on 200 V. If an inductor alone must swing the node with 6 A, how much inductance does ZVS need?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
A steady 10 A swings a switch node across 100 V, with 100 pF on each switch. How long does the transition take?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
A synchronous buck on 48 V with 100 pF switches and a 50 µH inductor wants ZVS. How much reverse current must flow when the low-side switch turns off?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A phase-shifted full bridge on 400 V at 100 kHz has 5 µH of leakage carrying 3 A on the primary. What duty cycle is lost to current reversal?
Check
An inductor of 20 µH rings with a leg's two 100 pF capacitances. What's the longest a resonant transition can take?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
An LLC reflects 200 V onto a magnetizing inductance of 100 µH at 250 kHz; its switches have 400 pF each and the bus is 2 × 200 V.
(a)
What magnetizing current is available at each transition?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
How long does it take to swing the node?
Check
A leg has output capacitance C per switch on a bus of V, switched at f; a current I swings the node.
Step 1
What would hard switching lose to one capacitance?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
How long does the soft transition take?
Explain why
Why is zero-voltage switching preferred for MOSFETs and zero-current switching for IGBTs?
A MOSFET turns off quickly and cleanly, since it has no stored minority charge, so its turn-off loss is small; its main switching loss is at turn-on, where the energy in its output capacitance is dumped into its own channel and the overlap of rising current and falling voltage adds more. ZVS removes exactly that, by swinging the voltage to zero before the gate is driven. An IGBT's problem is at turn-off: stored charge in its drift region keeps a tail current flowing while the voltage rises, and that tail can't be hurried. ZCS brings the current to zero before turn-off so the tail has nothing to dissipate against, which addresses the IGBT's dominant loss even though it leaves the capacitive turn-on loss in place.