S11 · Lesson 35 · Space-vector modulation
A three-phase inverter's eight switching states as vectors, synthesizing a rotating reference from two active vectors and zero vectors, dwell times, the 15% more voltage than sinusoidal PWM, and six-step operation
Lesson 33's sinusoidal PWM treats a three-phase inverter as three separate legs, each chasing its own sine. But the motor or grid it feeds sees only the line-to-line voltages, and the three legs together have just eight possible switch combinations. Space-vector modulation works with those eight states directly: it represents them as vectors in a plane and builds the desired rotating voltage vector from the two nearest ones each switching period. The result uses the DC bus better, giving about 15% more output voltage from the same bus, which is why almost every motor drive uses it or its equivalent.
- The curves are the three dwell times in one switching period for a reference of index m at angle θ within a 60° sector: the first active vector , the second , and the zero vectors the rest.
- At m = 1 the zero-vector time falls to zero at θ = 30°: the reference touches the hexagon's inscribed circle, the limit of linear modulation.
- At θ = 0 or 60° only one active vector is used, because the reference points straight at it.
Predict
A drive's DC bus is 700 V. What is the largest line-to-line RMS voltage it can produce without overmodulation, with sinusoidal PWM and with space-vector modulation?
Sinusoidal PWM peaks at m = 1: = 429 V. Space-vector modulation reaches a line-to-line peak equal to the whole bus, = 495 V RMS: 15.5% more, the same gain that third-harmonic injection gives. That's the difference between running a 480 V motor at full voltage from a 700 V bus or not.
Name it
Switching states as vectors
Each leg connects its phase to the top or bottom of the bus, so the inverter has = 8 states. Transforming the three phase voltages to the plane (, ), six states give active vectors of length at 0°, 60°, …, 300°, the corners of a hexagon, and two (all legs high or all low) give zero vectors.
Synthesis
To produce a reference vector at angle θ within a sector, apply the two adjacent active vectors for times
with , filling the rest of the period with zero vectors split between the all-low and all-high states. The average over the period equals the reference.
Limits
Linear modulation holds while the reference circle fits inside the hexagon, (m ≤ 1). Then the line-to-line peak is and its RMS , against for sinusoidal PWM. Beyond it, overmodulation ends in six-step operation, each leg a square wave, with a line-to-line fundamental of RMS and large low-order harmonics.
Choices within the period
Splitting the zero time equally between the two zero states centers the pulses and minimizes ripple; using only one zero state per sector (discontinuous PWM) leaves one leg unswitched for 60° at a time, cutting switching loss by about a third at some cost in ripple.
Worked example
A reference of m = 0.8 sits 20° into a sector, with a 100 µs switching period. Find the dwell times.
Show the solution
- First active vector.
- Second active vector.
- Zero vectors. usually 10.6 µs at each end of the period.
- The pattern. The closer the reference is to an active vector, the longer that vector is used.
Answer = 51.4 µs, = 27.4 µs and = 21.2 µs (10.6 µs at each end).
Worked example
What DC bus does a 480 V (line-to-line RMS) motor need with sinusoidal PWM, and with space-vector modulation?
Show the solution
- Sinusoidal PWM.
- Space-vector modulation.
- What a six-pulse rectifier gives. On a 480 V line it makes about short of both at full voltage, which is why such drives accept a little overmodulation or field weakening near rated speed.
Answer 784 V with sinusoidal PWM, and 679 V with space-vector modulation.
Worked example
A 700 V bus is run in six-step. What line-to-line fundamental results, compared with the linear limit?
Show the solution
- Six-step fundamental. RMS, line to line.
- Against the linear limit. Space-vector modulation's linear limit is so six-step gives 10% more.
- The cost. The extra voltage comes with 5th and 7th harmonics of 20% and 14% of the fundamental, so six-step is used only at the top of a motor's speed range.
Answer 546 V RMS line to line, 10% above the 495 V linear limit.
Check
A space-vector reference of index m = 0.7 sits 10° into a sector, with a switching period of 100 µs.
(a)
How long is the first active vector applied?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
(b)
How much time is left for the zero vectors?
Check
A three-phase inverter runs from a 700 V bus.
(a)
What is the largest line-to-line RMS voltage with space-vector modulation (linear range)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And in six-step?
Check
A motor is rated 400 V line to line.
(a)
What DC bus does space-vector modulation need for full voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And sinusoidal PWM?
Check
A 600 V bus feeds a two-level three-phase inverter.
(a)
How long is each active space vector?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is the largest reference magnitude in linear modulation?
Check
An inverter runs in six-step.
(a)
What is its 7th harmonic, as a percentage of the fundamental?
Check
A drive switches at 10 kHz. With discontinuous PWM, each leg stops switching for a third of each fundamental cycle.
(a)
What is each leg's average switching frequency?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
Why does space-vector modulation reach 15% more line-to-line voltage than sinusoidal PWM from the same bus?
Check
A reference of index m sits t degrees into a sector of a V-volt inverter, switching period T.
Step 1
What is ?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is ?
Step 3
What is the reference's magnitude, in volts?
Check
Write dwell(m, theta_deg, Ts) for θ within 0 to 60°, and average_vector(m, theta_deg, Vdc): the time-average over one period of the two active vectors (length at 0° and 60°) and zero vectors, as a complex number.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
How does an inverter with only eight switch states produce a smoothly rotating voltage?
Each of the eight states puts a fixed voltage vector across the load, six pointing at the corners of a hexagon and two of zero length. Within one short switching period the inverter visits the two active vectors nearest the desired direction and a zero vector, for times chosen so that their average equals the desired vector. Because the switching period is much shorter than the load's electrical time constants, the motor or grid filter responds only to that average, and as the desired vector advances from one period to the next the average traces a smooth circle, with the switching leaving only high-frequency ripple.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.