S12 · Lesson 31 · DC machines
The commutator as a mechanical rectifier, generated voltage and torque in terms of flux and armature current, separately excited, shunt and series motors and their speed–torque curves, starting resistance, speed control by armature voltage and field weakening, and armature reaction
For a century the DC motor was the only machine whose speed could be controlled smoothly and precisely, which made it the motor of elevators, steel mills, streetcars and machine tools. Its commutator, a ring of copper segments with brushes riding on it, switches each armature coil's connection as it rotates, so that the armature's MMF always stands at 90° to the field: the ideal angle for torque, held mechanically. The equations that result are the simplest in the course, and they're the model that every modern AC drive imitates.
- Speed against torque for a 240 V DC motor. A separately excited (or shunt) motor's speed falls in a straight line with torque, slightly; weakening its field (lower Φ) raises the whole line. Lowering the armature voltage lowers it.
- A series motor, whose field carries the armature current, runs fast at light load and slows sharply as torque rises: torque goes as the square of current.
- Unloaded, the series motor's speed would climb without limit, so series motors must never lose their load.
Predict
A separately excited DC motor has = 2.2 V·s/rad and = 0.2 Ω on 240 V. What current does it draw at the instant of starting?
At standstill there's no back-EMF, so only the armature resistance limits the current: 240/0.2 = 1200 A, about 24 times the 50 A rating. Starters add series resistance (here 2.2 Ω for 100 A) and cut it out in steps as the motor speeds up and its back-EMF builds.
Name it
Voltage and torque
With flux per pole Φ and mechanical speed , the armature's generated voltage and the torque its current produces are
with the same constant (set by the poles, conductors and parallel paths). Power balance: .
Motors
The armature circuit is for a motor, for a generator.
- Separately excited or shunt: constant Φ, so : a nearly flat speed–torque line.
- Series: the field carries , so (unsaturated) and . Speed falls as : high torque at low speed, dangerous overspeed at no load. Traction motors and starter motors are series machines.
Speed control
- Armature voltage (below base speed): speed ∝ at constant flux; full torque available at every speed.
- Field weakening (above base speed): speed ∝ 1/Φ at fixed ; torque at rated current falls as Φ, so power stays constant.
Armature reaction and commutation
The armature's MMF distorts the field, weakening it under one pole tip and strengthening it under the other, and the coil being commutated has voltage induced in it, causing sparking. Interpoles and compensating windings, carrying armature current, cancel both.
Worked example
The 240 V motor ( = 2.2 V·s/rad, = 0.2 Ω) carries 50 A. Find its speed, torque and power.
Show the solution
- Back EMF.
- Speed. (998 rpm), against 109.1 rad/s (1042 rpm) at no load.
- Torque and power.
- Starting resistance. To start it at 100 A, the armature circuit needs 240/100 = 2.4 Ω, so 2.2 Ω of starting resistance.
Answer it runs at 104.5 rad/s (998 rpm) and makes 110 N·m, a mechanical power of 11.5 kW.
Worked example
The field is weakened to 80% of rated flux. What happens to the speed and to the torque at 50 A?
Show the solution
- New flux constant. becomes 1.76 V·s/rad.
- No-load speed. (1302 rpm).
- Speed at 50 A. (1248 rpm).
- Torque at 50 A. the same 11.5 kW at a higher speed.
Answer at 50 A the speed rises to 130.7 rad/s (1248 rpm) and the torque falls to 88 N·m, the same 11.5 kW.
Worked example
A 240 V series motor runs at 1200 rpm drawing 40 A, with 0.3 Ω in its armature and field together. Estimate its speed and torque at 80 A, ignoring saturation.
Show the solution
- Back EMF at 40 A.
- Machine constant. With flux proportional to current, , so
- Speed at 80 A. Now = 216 V, so which is 568 rpm.
- Torque. The torque, , is four times as large: 290 N·m against 72.6 N·m.
- The series characteristic. Doubling the current halves the speed and quadruples the torque, the characteristic that made series motors the choice for streetcars and starter motors.
Answer at 80 A it runs at about 59.5 rad/s (568 rpm) and makes 290 N·m.
Check
A DC machine with = 2 V·s/rad turns at 500 rpm. What's its generated voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A DC motor on 240 V with = 1 V·s/rad and = 0.4 Ω draws 80 A. How fast does it turn?
Check
A DC motor with = 2 V·s/rad carries 10 A. What torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A DC motor on 240 V has = 0.05 Ω. What series resistance limits its starting current to 150 A?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A shunt motor runs at 1500 rpm (light load). Its field is weakened to 0.6 of its flux. About how fast does it run now?
Check
An unsaturated series motor makes 200 N·m at rated current. What does it make at 0.5 of rated current?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A series motor on 120 V, with 0.3 Ω in its armature and field, runs at 1500 rpm drawing 50 A. Ignore saturation.
(a)
At what speed does it run drawing 1.5 times that current?
(b)
By what factor has its torque changed?
Check
A separately excited DC motor on V volts has = k and armature resistance R, carrying torque T.
Step 1
What armature current flows?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
At what speed (rad/s) does it run?
Explain why
Why does a DC series motor run away if its load is removed, while a shunt motor doesn't?
A motor speeds up until its back-EMF, , nearly equals the supply voltage. In a shunt motor the field is fed separately, so Φ stays fixed and the speed levels off at . In a series motor the field current is the armature current. At light load the armature needs little current, so the flux becomes small, and the motor must spin faster and faster to generate enough back-EMF from that weak field. With no load at all the current and flux approach zero and the speed rises until friction, windage or a failing commutator stops it.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.