S12 · Lesson 39 · The dq0 transformation
Space vectors, Clarke's transformation to two stationary axes, Park's transformation onto axes that turn with the rotor, why sinusoidal three-phase quantities become constants, power and torque in dq variables, and the dq voltage equations with their speed-voltage terms
The steady-state circuits of the last twenty lessons assume sinusoids at one frequency. Transients, faults and inverter control don't oblige. In the stator's own coordinates a machine's inductances vary with rotor angle, so its differential equations have time-varying coefficients. Park's 1929 transformation removes that: express the three phase quantities on two axes that turn with the rotor, one along its poles and one between them, and the inductances become constants, balanced sinusoids become steady DC values, and the machine's dynamics become a handful of ordinary differential equations.
- The stator current as a single space vector of length I (three balanced phase currents at the instant ωt), and a d–q frame turned to the rotor angle θ.
- The d and q components are the vector's projections on the rotor's axes: and .
- Advance time and the rotor together (as in steady state) and the projections don't change: in the rotor's frame, AC quantities are DC.
Predict
Balanced currents of 10 A peak flow, and the rotor's d axis sits 30° behind the current's space vector. What are and ?
The space vector has length 10 A and is 30° ahead of the d axis, so its projections are = 8.66 A along d and = 5 A along q. If the rotor turns in step with the currents, as it does in a synchronous machine, these stay constant.
Name it
The space vector
Three phase quantities with axes 0°, 120° and 240° combine into one rotating vector (amplitude-invariant form):
For balanced currents of peak I it has constant length I and turns at ω. Clarke's transformation takes its real and imaginary parts, and , on fixed axes.
Park's transformation
On axes turned to the rotor's electrical angle θ:
The zero-sequence component is zero in a balanced or ungrounded system.
Power and torque
With the amplitude-invariant scaling, power picks up a factor 3/2:
Voltage equations
In the rotating frame, with electrical speed and flux linkages , :
The terms are speed voltages, the rotating-frame view of the back-EMF. For a permanent-magnet machine, and , with constant and .
Worked example
At one instant = 10 A, = −5 A, and the rotor's d axis lies along phase a (θ = 0). Find the dq0 currents.
Show the solution
- d-axis current. With θ = 0,
- q-axis current.
- Zero-sequence current. = 0.
- Check. The current vector points straight along d, as it should when phase a is at its peak and the other two at half that, negative.
Answer = 10 A, = 0 and = 0.
Worked example
A permanent-magnet machine with 8 poles and = 0.1 Wb carries = 20 A, = 0. Find its torque, and its steady at 2000 rad/s electrical with R = 0.05 Ω.
Show the solution
- Torque. With = 0,
- q-axis voltage. In steady state, almost all speed voltage.
- d-axis voltage. , which depends on .
Answer the torque is 12 N·m, and = 201 V.
Worked example
A controller commands = 0 and = 20 A with the rotor at θ = 30°. What phase currents result?
Show the solution
- Inverse transformation. It's , and the same with θ − 120° and θ + 120° for phases b and c.
- Phase currents. which sum to zero.
- As the rotor turns. These three sinusoids follow it, always placing the current 90° ahead of the magnet's flux, where it makes the most torque per ampere.
Answer = −10 A, = 20 A and = −10 A.
Check
Balanced currents of 10 A peak have their space vector 10° ahead of the rotor's d axis. What's ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
For the same currents (10 A peak, 10° ahead of d), what's ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A machine has = 50 V, = 20 V, = 30 A and = 40 A (amplitude-invariant). What power flows?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
The phase currents at one instant are 8, −2 and −0.5 A. What's the zero-sequence current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
An 8-pole surface PM machine with = 0.05 Wb carries = 50 A and = 0. What torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A PM machine (R = 0.02 Ω, = 0.15 Wb) runs steadily at 2000 rad/s electrical with = 10 A and = 0. What's ?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
At one instant = 8 A and = −9 A in a three-wire system.
(a)
What is ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is ?
(c)
How long is the current space vector?
Check
A PM machine with P poles and magnet flux linkage m carries = q and = d, with = x and = y.
Step 1
What is its magnet torque?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is its reluctance torque?
Explain why
Why do a synchronous machine's inductances become constant in the dq frame?
In the stator's own coordinates, a salient rotor's position changes how easily each phase's flux crosses the gap, so every self and mutual inductance between the phases varies with rotor angle, at twice the electrical angle. The d and q axes are fixed to the rotor's geometry: d along the poles, q between them. Seen from axes that turn with the rotor, the magnetic paths never change: flux along d always meets the pole faces and flux along q always meets the interpolar gaps. So the inductances along those axes, and , are constants, and the coupling between the axes appears only through the speed-voltage terms , which are exactly what a rotating frame adds.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.