S1241 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S12 · Lesson 41 · Field-oriented control of induction motors

Aligning the dq frame with the rotor flux so that one stator current component sets the flux and the other the torque, the rotor time constant, the slip frequency that indirect field orientation computes, and the induction motor made to behave like a separately excited DC machine

Volts-per-hertz control is fine for fans and pumps but slow for anything that needs fast, precise torque: a machine tool's spindle, a rolling mill, an electric car. The DC machine had that naturally, with field current setting the flux and armature current the torque, independently. Field-oriented control, developed by Blaschke and Hasse around 1970, gives an induction motor the same decoupling. In a dq frame aligned with the rotor's flux, the d-axis stator current sets the flux, the q-axis current sets the torque, and an inverter with fast current control makes them follow their commands within milliseconds.

  • A field-oriented induction motor: the d-axis current steps on at t = 0 and the rotor flux builds with the rotor time constant τr; the torque command (q-axis current) steps on at the slider's time.
  • Torque is proportional to the flux times iqs. Once the flux has built up, torque follows the q current instantly, like a DC motor's armature current.
  • A torque command before the flux is established gives a sluggish response, which is why drives premagnetize the motor.

Predict

In rotor-flux-oriented control, the q-axis current is stepped from 0 to 30 A while the flux is held constant. How does the torque respond?

Name it

Rotor-flux orientation

Choose the d axis along the rotor flux linkage λr, so λqr = 0. With magnetizing inductance Lm, rotor inductance Lr and resistance Rr, the rotor time constant is τr=Lr/Rr and:

  • Flux: τrdλrdt+λr=Lmids, so in steady state λr=Lmids.
  • Torque: T=32P2LmLrλriqs.
  • Slip: for the frame to stay on the flux, the slip frequency (electrical rad/s) must be
ωsl=Lmiqsτrλr

Indirect field orientation

Measure the rotor's electrical speed ωr, add the computed slip, and integrate: θ=∫(ωr+ωsl)dt is the flux angle used in the Park transformation. Current regulators (PI controllers in the dq frame) drive ids and iqs to their commands. The method depends on knowing τr, which drifts with rotor temperature; a wrong value misaligns the frame and couples flux and torque again.

The DC-machine analogy

ids plays the field current (slow, set once), iqs the armature current (fast, sets torque). Above base speed, ids is reduced to weaken the flux, exactly as a DC motor's field is weakened.

Worked example

A 4-pole motor has Lm = 50 mH, Lr = 52 mH and Rr = 0.2 Ω. For rated rotor flux of 0.5 Wb and iqs = 30 A, find ids, torque and slip.

Show the solution
  1. Rotor time constant. τr=0.0520.2=0.26s
  2. d-axis current. ids=0.50.05=10A
  3. Torque. T=1.5×2×0.050.052×0.5×30=43.3N·m
  4. Slip. ωsl=0.05×300.26×0.5=11.5rad/s electrical, 1.84 Hz.
  5. Inverter frequency. At 1700 rpm the rotor turns at 356.0 electrical rad/s, so the inverter's frequency is f=356.0+11.52π=58.5Hz

Answer ids = 10 A, the torque is 43.3 N·m, and the slip is 11.5 rad/s electrical (1.84 Hz), so at 1700 rpm the inverter runs at 58.5 Hz.

Worked example

Starting from a de-energized motor, how long must the drive premagnetize before full torque is available?

Show the solution
  1. How the flux builds. It grows as 1−e−t/τr, reaching 95% in 3τr = 0.78 s for this motor.
  2. Speeding it up. Drives often apply extra d-axis current at first to speed this up, then fall back to the rated value.
  3. Large motors. Large motors with rotor time constants of a second or more take several seconds.

Answer about 0.78 s, three rotor time constants, for the flux to reach 95%.

Worked example

The 4-pole motor is run at 1.5 times base speed with its rotor flux weakened in proportion. With the same iqs = 30 A, what are ids, the torque and the slip?

Show the solution
  1. Flux and d-axis current. The flux falls to 0.5/1.5 = 0.333 Wb, so ids=0.5/1.50.05=6.67A
  2. Torque. Torque is proportional to the flux at a given iqs: T=43.31.5=28.9N·m
  3. Slip. The slip, inversely proportional to the flux, rises to ωsl=0.05×300.26×0.333=17.3rad/s
  4. Power. The power, torque times speed, is the same as at base speed: the constant-power region, as in a DC motor with its field weakened.

Answer ids = 6.67 A, the torque is 28.9 N·m, and the slip rises to 17.3 rad/s.

Check

A motor with Lm = 20 mH needs rotor flux 0.6 Wb. What steady d-axis current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A 4-pole motor with Lr = 1.03 Lm runs at rotor flux 1 Wb and iqs = 60 A. What torque does it make?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

A rotor has Lr = 100 mH and Rr = 0.05 Ω. What's its time constant?

Write units the way you normally would: 1.5 s and 1500 ms are the same answer.

Check

With Lm = 30 mH, τr = 1 s, rotor flux 1 Wb and iqs = 10 A, what slip frequency must the controller impose?

Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.

Check

A 4-pole rotor turns at 1500 rpm and the controller adds a slip of 40 electrical rad/s. What frequency does the inverter apply?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

With rotor time constant 0.3 s, how long after the d-axis current steps on does the flux reach 0.9 of its final value?

Write units the way you normally would: 1.5 s and 1500 ms are the same answer.

Check

A 4-pole induction motor has Lm = 30 mH, Lr = 1.03Lm and Rr = 0.4 Ω. Its field-oriented drive holds the rotor flux at 0.8 Wb with iqs = 10 A.

(a)

What is ids?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What torque does it make?

(c)

What slip frequency (electrical) must it impose?

Check

An induction motor has Lm = m, Lr = r and Rr = R, with rotor flux l and iqs = q under field orientation.

Step 1

What is its rotor time constant?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does indirect field-oriented control need an accurate value of the rotor time constant?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.