title: Field-oriented control of induction motors
heading: Aligning the dq frame with the rotor flux so that one stator current component sets the flux and the other the torque, the rotor time constant, the slip frequency that indirect field orientation computes, and the induction motor made to behave like a separately excited DC machine
eyebrow: S12 · Lesson 41 · Field-oriented control of induction motors
xp: 50
---

::: hook
Volts-per-hertz control is fine for fans and pumps but slow for anything that needs fast, precise torque: a machine tool's spindle, a rolling mill, an electric car. The DC machine had that naturally, with field current setting the flux and armature current the torque, independently. Field-oriented control, developed by Blaschke and Hasse around 1970, gives an induction motor the same decoupling. In a dq frame aligned with the rotor's flux, the d-axis stator current sets the flux, the q-axis current sets the torque, and an inverter with fast current control makes them follow their commands within milliseconds.
:::

::: play
- A field-oriented induction motor: the d-axis current steps on at t = 0 and the rotor flux builds with the rotor time constant $\tau_r$; the torque command (q-axis current) steps on at the slider's time.
- Torque is proportional to the flux times $i_{qs}$. Once the flux has built up, torque follows the q current instantly, like a DC motor's armature current.
- A torque command before the flux is established gives a sluggish response, which is why drives premagnetize the motor.
:::

```sim plot
view: graph
x: t = 0..1.5 s
y: y = 0..50
slider: r = 0.05..0.5 step 0.01 = 0.26 s
slider: a = 0..1.2 step 0.05 = 0.8 s
plot: 50*(1 - exp(-t/r)) | samples: 400 | dashed | color: ch3 | label: rotor flux, % of rated ÷ 2
plot: 1.5*2*(0.05/0.052)*0.05*10*(1 - exp(-t/r))*30*step(t - a) | samples: 400 | label: torque, N·m
readout: time to 95% flux, s = 3*r | digits: 3
```

::: predict
## In rotor-flux-oriented control, the q-axis current is stepped from 0 to 30 A while the flux is held constant. How does the torque respond?

- [ ] With the rotor time constant, about a quarter second
- [x] Essentially instantly, limited only by how fast the inverter can change the current
- [ ] With the mechanical time constant
- [ ] It doesn't change until the slip builds up

::: reveal
With the frame aligned to the rotor flux, the torque is $\frac{3}{2}\frac{P}{2}\frac{L_m}{L_r}\lambda_ri_{qs}$, and a change in $i_{qs}$ doesn't disturb $\lambda_r$. The controller simultaneously changes the slip frequency in proportion, so the rotor currents rearrange at once. Torque follows the current, which a fast current loop changes in a millisecond or so.
:::
:::

::: nameit
## Rotor-flux orientation

Choose the d axis along the rotor flux linkage $\lambda_r$, so $\lambda_{qr}$ = 0. With magnetizing inductance $L_m$, rotor inductance $L_r$ and resistance $R_r$, the rotor time constant is $\tau_r = L_r/R_r$ and:

- **Flux:** $\tau_r\dfrac{d\lambda_r}{dt} + \lambda_r = L_mi_{ds}$, so in steady state $\lambda_r = L_mi_{ds}$.
- **Torque:** $T = \dfrac{3}{2}\dfrac{P}{2}\dfrac{L_m}{L_r}\lambda_ri_{qs}$.
- **Slip:** for the frame to stay on the flux, the slip frequency (electrical rad/s) must be

$$\omega_\text{sl} = \frac{L_mi_{qs}}{\tau_r\lambda_r}$$

## Indirect field orientation

Measure the rotor's electrical speed $\omega_r$, add the computed slip, and integrate: $\theta = \int(\omega_r + \omega_\text{sl})\,dt$ is the flux angle used in the Park transformation. Current regulators (PI controllers in the dq frame) drive $i_{ds}$ and $i_{qs}$ to their commands. The method depends on knowing $\tau_r$, which drifts with rotor temperature; a wrong value misaligns the frame and couples flux and torque again.

## The DC-machine analogy

$i_{ds}$ plays the field current (slow, set once), $i_{qs}$ the armature current (fast, sets torque). Above base speed, $i_{ds}$ is reduced to weaken the flux, exactly as a DC motor's field is weakened.
:::

::: example
## A 4-pole motor has $L_m$ = 50 mH, $L_r$ = 52 mH and $R_r$ = 0.2 Ω. For rated rotor flux of 0.5 Wb and $i_{qs}$ = 30 A, find $i_{ds}$, torque and slip.

::: solution
1. **Rotor time constant.**
   $$\begin{aligned} \tau_r &= \frac{0.052}{0.2} \\ &= 0.26\ \text{s} \end{aligned}$$
2. **d-axis current.**
   $$\begin{aligned} i_{ds} &= \frac{0.5}{0.05} \\ &= 10\ \text{A} \end{aligned}$$
3. **Torque.**
   $$\begin{aligned} T &= 1.5 \times 2 \times \frac{0.05}{0.052} \\ &\quad \times 0.5 \times 30 \\ &= 43.3\ \text{N·m} \end{aligned}$$
4. **Slip.**
   $$\begin{aligned} \omega_{sl} &= \frac{0.05 \times 30}{0.26 \times 0.5} \\ &= 11.5\ \text{rad/s} \end{aligned}$$
   electrical, 1.84 Hz.
5. **Inverter frequency.** At 1700 rpm the rotor turns at 356.0 electrical rad/s, so the inverter's frequency is
   $$\begin{aligned} f &= \frac{356.0 + 11.5}{2\pi} \\ &= 58.5\ \text{Hz} \end{aligned}$$

**Answer:** $i_{ds}$ = 10 A, the torque is 43.3 N·m, and the slip is 11.5 rad/s electrical (1.84 Hz), so at 1700 rpm the inverter runs at 58.5 Hz.
:::
:::

::: example
## Starting from a de-energized motor, how long must the drive premagnetize before full torque is available?

::: solution
1. **How the flux builds.** It grows as $1 - e^{-t/\tau_r}$, reaching 95% in $3\tau_r$ = 0.78 s for this motor.
2. **Speeding it up.** Drives often apply extra d-axis current at first to speed this up, then fall back to the rated value.
3. **Large motors.** Large motors with rotor time constants of a second or more take several seconds.

**Answer:** about 0.78 s, three rotor time constants, for the flux to reach 95%.
:::
:::

::: example
## The 4-pole motor is run at 1.5 times base speed with its rotor flux weakened in proportion. With the same $i_{qs}$ = 30 A, what are $i_{ds}$, the torque and the slip?

::: solution
1. **Flux and d-axis current.** The flux falls to 0.5/1.5 = 0.333 Wb, so
   $$\begin{aligned} i_{ds} &= \frac{0.5/1.5}{0.05} \\ &= 6.67\ \text{A} \end{aligned}$$
2. **Torque.** Torque is proportional to the flux at a given $i_{qs}$:
   $$\begin{aligned} T &= \frac{43.3}{1.5} \\ &= 28.9\ \text{N·m} \end{aligned}$$
3. **Slip.** The slip, inversely proportional to the flux, rises to
   $$\begin{aligned} \omega_{sl} &= \frac{0.05 \times 30}{0.26 \times 0.333} \\ &= 17.3\ \text{rad/s} \end{aligned}$$
4. **Power.** The power, torque times speed, is the same as at base speed: the constant-power region, as in a DC motor with its field weakened.

**Answer:** $i_{ds}$ = 6.67 A, the torque is 28.9 N·m, and the slip rises to 17.3 rad/s.
:::
:::

::: check
given: l = 0.3 | 0.6 | 1.2; M = 20 | 50 | 150
answer: l/(M*1e-3)
unit: A
tolerance: 0.5%

## A motor with $L_m$ = {M} mH needs rotor flux {l} Wb. What steady d-axis current?

::: right
Right. $\lambda_r/L_m$ = {answer} A.
:::

::: misses
- [any] Not yet. In steady state $\lambda_r = L_mi_{ds}$.
:::
:::

::: check
given: P = 2 | 4 | 6; k = 1.03 | 1.06; l = 0.4 | 1; q = 10 | 60
answer: 1.5*P/2/k*l*q
unit: N·m
tolerance: 0.5%

## A {P}-pole motor with $L_r$ = {k} $L_m$ runs at rotor flux {l} Wb and $i_{qs}$ = {q} A. What torque does it make?

::: right
Right. $\frac{3}{2}\frac{P}{2}\frac{L_m}{L_r}\lambda_ri_{qs}$ = {answer} N·m.
:::

::: misses
- [1.5*P/2*l*q] Include $L_m/L_r$.
- [any] Not yet. The rotor-flux torque equation.
:::
:::

::: check
given: L = 30 | 100 | 300; R = 0.05 | 0.2 | 1
answer: L*1e-3/R
unit: s
tolerance: 0.5%

## A rotor has $L_r$ = {L} mH and $R_r$ = {R} Ω. What's its time constant?

::: right
Right. $L_r/R_r$ = {answer} s.
:::

::: misses
- [any] Not yet. $\tau_r = L_r/R_r$.
:::
:::

::: check
given: M = 30 | 100; q = 10 | 60; t = 0.1 | 0.3 | 1; l = 0.4 | 1
answer: M*1e-3*q/(t*l)
unit: rad/s
tolerance: 0.5%

## With $L_m$ = {M} mH, $\tau_r$ = {t} s, rotor flux {l} Wb and $i_{qs}$ = {q} A, what slip frequency must the controller impose?

::: right
Right. $L_mi_{qs}/(\tau_r\lambda_r)$ = {answer} rad/s.
:::

::: misses
- [M*1e-3*q/(t*l)/(2*pi)] That's in hertz; the question asks for rad/s.
- [any] Not yet. Indirect field orientation's slip relation.
:::
:::

::: check
given: n = 600 | 1500 | 2900; P = 4 | 6; w = 5 | 15 | 40
answer: (n*2*pi/60*P/2 + w)/(2*pi)
unit: Hz
tolerance: 0.5%

## A {P}-pole rotor turns at {n} rpm and the controller adds a slip of {w} electrical rad/s. What frequency does the inverter apply?

::: right
Right. $(\omega_r + \omega_\text{sl})/2\pi$ = {answer} Hz.
:::

::: misses
- [(n*2*pi/60 + w)/(2*pi)] Convert mechanical speed to electrical: multiply by P/2.
- [any] Not yet. Electrical rotor speed plus slip.
:::
:::

::: check
given: t = 0.1 | 0.3 | 1.2; p = 0.9 | 0.95 | 0.99
answer: -t*ln(1 - p)
unit: s
tolerance: 0.5%

## With rotor time constant {t} s, how long after the d-axis current steps on does the flux reach {p} of its final value?

::: right
Right. $-\tau_r\ln(1 - p)$ = {answer} s.
:::

::: misses
- [-t*log(1 - p)] Use the natural logarithm.
- [any] Not yet. First-order rise.
:::
:::

::: check
kind: parts
given: m = 30 | 80; r = 1.03 | 1.05; R = 0.1 | 0.4; l = 0.4 | 0.8; q = 10 | 40; P = 4 | 6

## A {P}-pole induction motor has $L_m$ = {m} mH, $L_r$ = {r}$L_m$ and $R_r$ = {R} Ω. Its field-oriented drive holds the rotor flux at {l} Wb with $i_{qs}$ = {q} A.

::: part
answer: l/(m*1e-3)
unit: A
tolerance: 0.5%

### What is $i_{ds}$?

::: misses
- [any] $\lambda_r/L_m$.
:::
:::

::: part
answer: 1.5*P/2*(1/r)*l*q
unit: N·m
tolerance: 0.5%

### What torque does it make?

::: misses
- [1.5*P/2*l*q] Include $L_m/L_r$.
- [any] $\frac32\frac P2\frac{L_m}{L_r}\lambda_ri_{qs}$.
:::
:::

::: part
answer: m*1e-3*q*R/(r*m*1e-3*l)
unit: rad/s
tolerance: 0.5%

### What slip frequency (electrical) must it impose?

::: misses
- [any] $L_mi_{qs}/(\tau_r\lambda_r)$ with $\tau_r = L_r/R_r$.
:::
:::
:::

::: check
kind: derivation
vars: m = 0.01..0.5, r = 0.01..0.6, R = 0.01..2, l = 0.1..2, q = 1..200

## An induction motor has $L_m$ = m, $L_r$ = r and $R_r$ = R, with rotor flux l and $i_{qs}$ = q under field orientation.

::: step
answer: r/R

### What is its rotor time constant?
:::

::: step
answer: m*q*R/(r*l)

### What slip frequency keeps the frame on the flux?
:::

::: right
Right. A wrong estimate of $R_r$ makes the drive misplace the flux, which is why drives track the rotor's temperature.
:::
:::

::: explain
## Why does indirect field-oriented control need an accurate value of the rotor time constant?

::: model
Indirect field orientation doesn't measure the rotor flux; it computes where the flux must be by adding a calculated slip frequency, $L_mi_{qs}/(\tau_r\lambda_r)$, to the measured rotor speed and integrating. If the controller's $\tau_r$ is wrong, for instance because the rotor bars' resistance has risen 30% as the motor warmed up, the computed slip is wrong, the assumed frame drifts away from the true flux, and the currents the controller labels d and q no longer separate flux from torque. The result is a flux that's too high or too low and a torque that no longer follows the q-axis command, with sluggish or oscillating response. Practical drives estimate the rotor resistance online or use flux observers.
:::
:::

::: practice

::: check
given: P = 4 | 8; k = 1.02 | 1.08; l = 0.3 | 1.2; q = 5 | 100
answer: 1.5*P/2/k*l*q
unit: N·m
tolerance: 0.5%

## Torque: {P} poles, $L_r/L_m$ = {k}, {l} Wb, {q} A?

::: misses
- [any] $\frac{3}{2}\frac{P}{2}\frac{L_m}{L_r}\lambda_ri_q$.
:::
:::

::: check
given: M = 20 | 200; q = 5 | 80; t = 0.05 | 2; l = 0.3 | 1.2
answer: M*1e-3*q/(t*l)
unit: rad/s
tolerance: 0.5%

## Slip: $L_m$ = {M} mH, $i_q$ = {q} A, $\tau_r$ = {t} s, {l} Wb?

::: misses
- [any] $L_mi_q/(\tau_r\lambda_r)$.
:::
:::

::: check
given: l = 0.2 | 1.5; M = 15 | 300
answer: l/(M*1e-3)
unit: A
tolerance: 0.5%

## $i_{ds}$ for {l} Wb with $L_m$ = {M} mH?

::: misses
- [any] $\lambda_r/L_m$.
:::
:::
:::