S12 · Lesson 20 · The induction machine and its equivalent circuit
A rotor that runs slower than the field so that currents are induced in it, slip and rotor frequency, referring the rotor to the stator, the per-phase equivalent circuit with its load resistance, and how air-gap power divides between rotor loss and mechanical power
The induction motor is the workhorse of industry: no brushes, no magnets, often no rotor windings at all, just aluminum bars cast into a stack of laminations and shorted at the ends. The stator's rotating field sweeps past the bars, induces currents in them, and drags the rotor along. It can never quite catch up, since a rotor turning with the field would see no change in flux and carry no current, and how far it falls behind, the slip, sets everything else.
- A 460 V, 4-pole, 60 Hz induction motor's stator current and torque against speed, from its equivalent circuit (R₁ = 0.2, X₁ = 0.5, = 20, R₂ = 0.15, X₂ = 0.5 Ω per phase).
- Near synchronous speed (1800 rpm) both are small; under load the speed drops a few percent and the torque rises steeply. At standstill the current is many times its full-load value.
- The readouts follow the speed slider: slip, rotor frequency, current and torque.
Predict
A 4-pole, 60 Hz induction motor runs at 1764 rpm. What frequency are the currents in its rotor bars?
The field turns at 1800 rpm and the rotor at 1764, so the slip is 36/1800 = 0.02, and the field sweeps past the rotor at 2% of its stator speed. The rotor's currents alternate at = 0.02 × 60 = 1.2 Hz. Their own field turns at 1.2 Hz × 60/2 = 36 rpm relative to the rotor, so in space it rotates in step with the stator's.
Name it
Slip
With synchronous speed and rotor speed n,
Rotor currents have frequency , and their MMF rotates relative to the rotor at , so in space it turns at , locked to the stator's field whatever the speed.
The equivalent circuit
The rotor, referred to the stator turns, behaves like a transformer secondary whose induced voltage and reactance both scale with s. Dividing through by s gives a per-phase circuit at stator frequency:
- stator resistance and leakage reactance ;
- the magnetizing reactance (and sometimes a core-loss resistance ) across the air-gap voltage;
- the rotor's leakage reactance and a resistance .
Power flow
The power crossing the air gap is . Split :
- rotor copper loss ;
- mechanical power , and torque .
The shaft delivers less friction, windage and stray losses. A rotor can never be more efficient than .
Worked example
The 460 V motor at 2% slip, with 500 W of rotational loss: find current, power factor, torque, output and efficiency.
Show the solution
- Phase voltage and rotor resistance. V = 265.6 V per phase and = 7.5 Ω.
- Currents. The input impedance works out to 6.50 + j3.29 Ω, so = 36.5 A at 0.892 power factor, and = 33.4 A.
- Air-gap power and torque.
- Output. The mechanical power is 24.62 kW, so after 500 W of rotational loss the output is 24.12 kW (32 hp).
- Input and efficiency. so the efficiency is 93.1%.
- Losses. 0.80 kW in the stator copper, 0.50 kW in the rotor, 0.50 kW rotational.
Answer 36.5 A at 0.892 power factor, 133.3 N·m of torque, and 24.12 kW (32 hp) of output at 93.1% efficiency.
Worked example
A 6-pole, 50 Hz motor delivers 40 kW of mechanical power at 970 rpm. What's its rotor copper loss?
Show the solution
- Slip. = 1000 rpm, so s = 0.03.
- Air-gap power.
- Rotor copper loss.
- Torque.
Answer the rotor copper loss is 1.24 kW (and the torque 393.8 N·m).
Worked example
Find the 460 V motor's starting current and power factor at full voltage ( = 0.2, = 0.5, = 20, = 0.15, = 0.5 Ω).
Show the solution
- Rotor branch at standstill. At s = 1 the rotor branch is just 0.15 + j0.5 Ω, and in parallel with j20 Ω it becomes 0.143 + j0.489 Ω.
- Input impedance. With the stator's 0.2 + j0.5 Ω, the input impedance is 1.047 Ω at a power factor of 0.33.
- Starting current. seven times the 36.5 A full-load current.
- What it means. That inrush is why large motors need reduced-voltage starting (lesson 25) and why a motor start dims the lights.
Answer 254 A at a power factor of 0.33, seven times the full-load current.
Check
A 2-pole, 50 Hz induction motor runs at 2850 rpm. What's its slip?
Check
An induction motor on 50 Hz runs at slip 0.01. What's the frequency of its rotor currents?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
An induction motor's air-gap power is 30 kW at slip 0.01. How much is lost in the rotor's copper?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
An induction motor develops 30 kW of mechanical power at slip 0.01. What's its air-gap power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
A 6-pole, 50 Hz induction motor's air-gap power is 30 kW. What torque does it develop?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A three-phase induction motor's referred rotor current is 20 A with = 0.1 Ω at slip 0.04. What's the air-gap power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
A 4-pole, 50 Hz induction motor runs at 0.05 slip with 200 kW crossing its air gap.
(a)
At what speed does it turn?
(b)
What frequency do its rotor currents have?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(c)
What is its rotor copper loss?
Check
An induction motor has air-gap power A at slip s, with synchronous speed w rad/s.
Step 1
What is its rotor copper loss?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What mechanical power does it develop?
Step 3
What torque?
Explain why
Why can't an induction motor's rotor be more efficient than 1 − s?
All the power that crosses the air gap is carried by the rotating field, which turns at synchronous speed, so the torque on the rotor equals the air-gap power divided by synchronous speed. The rotor turns slower, at times synchronous speed, so the mechanical power it delivers is the same torque times its own speed: times the air-gap power. The difference, , is the power needed to drive current through the rotor's resistance at slip frequency, and it ends up as heat. Running at 2% slip wastes at least 2%; running a motor slowly by increasing its slip wastes the whole difference in speed.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.