S12 · Lesson 50 · Induction motor lab

Solving an induction motor's full equivalent circuit in Python with complex numbers, finding its breakdown torque by Thévenin reduction and checking it against a direct search, and recovering the circuit from DC, no-load and blocked-rotor test data

Lessons 20 to 24 worked the 460 V motor by hand, one operating point at a time. In this lab you'll write the three functions a motor engineer actually uses: one that solves the equivalent circuit at any slip and returns everything on the nameplate, one that finds the breakdown point in closed form, and one that turns three bench tests into the circuit's parameters. Each is checked against the numbers the lessons computed.

Predict

Your breakdown function uses the Thévenin formula, and the test compares it with a brute-force search of the full circuit. Should they agree exactly?

Name it

The circuit in code

Complex arithmetic does the work: Z2=R2/s+jX2, Zp=jXm∥Z2, I1=V/(R1+jX1+Zp), I2=I1Zp/Z2. Air-gap power 3|I2|2R2/s, torque Pag/ωs, input 3VRe(I1), output (1−s)Pag−Prot.

Breakdown

Zth=jXm(R1+jX1)/(R1+j(X1+Xm)), Vth=|VjXm/(R1+j(X1+Xm))|; then smax⁡T and Tmax⁡ from lesson 23.

Parameters from tests

DC: R1=V/2I. No load: Xnl=Vϕ/I, Prot=P−3I2R1. Blocked rotor: R1+R2=P/3I2, X1+X2=Z2−R2×frated/ftest, split by class; Xm=Xnl−X1.

Worked example

What should performance(0.02) return for the 460 V motor?

Show the solution
  1. At 2% slip. I1 = 36.47 A at 0.892 power factor, T = 133.28 N·m, Pout = 24,120 W and efficiency 0.9305, the numbers of lesson 20.
  2. At standstill. At s = 1 it should give 253.8 A and 146.3 N·m, the starting values.

Answer 36.47 A at 0.892 power factor, 133.28 N·m, 24,120 W of output and an efficiency of 0.9305.

Worked example

What should extract recover from lesson 24's test data?

Show the solution
  1. The circuit. R1 = 0.200, R2 = 0.150, X1=X2 = 0.500 Ω (class A), Xm = 19.93 Ω and 498.6 W of rotational loss.
  2. Why Xm comes out low. The magnetizing reactance comes out 0.07 Ω below the motor's true 20 Ω, because the no-load test sees X1+Xm in parallel with a very large but finite rotor branch; the error is 0.35%, small enough to ignore.

Answer R1 = 0.200 Ω, R2 = 0.150 Ω, X1=X2 = 0.500 Ω, Xm = 19.93 Ω, and 498.6 W of rotational loss.

Check

Step 1. Write performance(s): the full equivalent circuit at any slip.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Step 2. Write breakdown(): the Thévenin closed form for the peak.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Check

Step 3. Write extract(dc, nl, br, f_test): the circuit from three tests.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

Why is the blocked-rotor test's reactance split between stator and rotor by a rule of thumb instead of measured?

Practice

Keep practicing

3 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.