title: Induction motor tests and parameters
heading: Finding the equivalent circuit from three measurements, the DC test for stator resistance, the no-load test for magnetizing reactance and rotational loss, the blocked-rotor test at reduced frequency for the leakage impedances, and splitting the leakage reactance by design class
eyebrow: S12 · Lesson 24 · Induction motor tests and parameters
xp: 50
---

::: hook
A motor's nameplate gives voltage, current, speed and power, but not the six numbers of its equivalent circuit. Three simple tests on the bench supply them, each designed so that one part of the circuit dominates: direct current sees only the stator copper, a free-running rotor at nearly zero slip leaves only the magnetizing branch, and a locked rotor shorts the magnetizing branch out with its small $R_2$. The results feed every calculation in the last four lessons.
:::

::: play
- The locus of the 460 V motor's stator current phasor as its slip goes from nearly zero to standstill: almost a circle (the classic circle diagram), with the voltage along the real axis.
- At no load the current is small and nearly 90° behind the voltage: magnetizing current. At full load it swings toward the voltage; at standstill it's large and lagging again, limited mainly by leakage reactance.
- The no-load and blocked-rotor tests measure the two ends of this curve.
:::

```sim plot
view: complex
range: 280
axes: in phase with V (A), quadrature (A)
curve: 265.58/(0.2 + j*0.5 + (j*20*(0.15/u + j*0.5))/(j*20 + 0.15/u + j*0.5)) | over: u = 0.0005..1 | dashed
arrow: 265.58/(0.2 + j*0.5 + (j*20*(0.15/0.0005 + j*0.5))/(j*20 + 0.15/0.0005 + j*0.5)) | label: no load
arrow: 265.58/(0.2 + j*0.5 + (j*20*(0.15/0.02 + j*0.5))/(j*20 + 0.15/0.02 + j*0.5)) | color: ch3 | label: full load
arrow: 265.58/(0.2 + j*0.5 + (j*20*(0.15 + j*0.5))/(j*20 + 0.15 + j*0.5)) | color: ch4 | label: standstill
```

::: predict
## On the blocked-rotor test, why can the magnetizing branch be ignored?

- [ ] The rotor isn't turning, so there's no magnetizing current
- [x] With s = 1 the rotor branch's impedance is tiny compared with $X_m$, so almost no current takes the magnetizing path
- [ ] The test is run at DC
- [ ] $X_m$ is shorted by the test leads

::: reveal
At standstill the rotor branch is $R_2 + jX_2$, about 0.5 Ω here, in parallel with $X_m$ = 20 Ω. Nearly all the current goes through the rotor branch, so the measured impedance is essentially $R_1 + R_2 + j(X_1 + X_2)$. The test is also run at reduced voltage, since full voltage would drive several times rated current.
:::
:::

::: nameit
## DC test

Apply DC between two terminals of the Y-connected stator: $R_1 = V_\text{dc}/(2I_\text{dc})$. (AC resistance is a little higher; the difference is usually ignored.)

## No-load test

Run at rated voltage with no load. The slip is tiny, $R_2/s$ is enormous, and the rotor branch carries almost nothing:

- per-phase reactance $X_\text{nl} \approx V_\phi/I_\text{nl} = X_1 + X_m$ (the resistance is small);
- **rotational loss** (friction, windage and core) $P_\text{rot} = P_\text{nl} - 3I_\text{nl}^2R_1$.

## Blocked-rotor test

Lock the rotor and raise the voltage until rated current flows, at a reduced frequency (often 25% of rated) so the rotor's current frequency resembles that in normal running, where deep bars behave differently than at 60 Hz:

$$R_\text{br} = \frac{P_\text{br}}{3I^2} = R_1 + R_2, \qquad X_\text{br}(f_\text{test}) = \sqrt{(V_\phi/I)^2 - R_\text{br}^2}$$

Scale the reactance to rated frequency, $X_1 + X_2 = X_\text{br}f_\text{rated}/f_\text{test}$, and split it by the motor's NEMA design class: equally for classes A and D, 40/60 for class B, 30/70 for class C. Then $X_m = X_\text{nl} - X_1$.
:::

::: example
## The 460 V motor's tests: DC 12 V at 30 A; no load 460 V, 13.0 A, 600 W; blocked rotor at 15 Hz, 26.8 V line, 36 A, 1361 W. Find its circuit (class A).

::: solution
1. **Stator resistance.** The DC test drives two phases in series:
   $$\begin{aligned} R_1 &= \frac{12}{2 \times 30} \\ &= 0.200\ \Omega \end{aligned}$$
2. **No-load test.** $V_\phi$ = 265.6 V, so
   $$\begin{aligned} X_\text{nl} &= \frac{265.6}{13.0} \\ &= 20.43\ \Omega \end{aligned}$$
   and the rotational loss is
   $$\begin{aligned} P_\text{rot} &= 600 - 3 \times 13^2 \times 0.2 \\ &= 499\ \text{W} \end{aligned}$$
3. **Blocked-rotor resistance.**
   $$\begin{aligned} R_\text{br} &= \frac{1361}{3 \times 36^2} \\ &= 0.350\ \Omega \end{aligned}$$
   so $R_2$ = 0.150 Ω.
4. **Blocked-rotor reactance.** $V_\phi$ = 15.47 V and |Z| = 0.430 Ω, so $X_\text{br}$ = 0.250 Ω at 15 Hz, 1.00 Ω at 60 Hz.
5. **Split the reactances (class A).** $X_1 = X_2$ = 0.50 Ω, and
   $$\begin{aligned} X_m &= 20.43 - 0.50 \\ &= 19.9\ \Omega \end{aligned}$$
   close to the 20 Ω the motor was built with.

**Answer:** $R_1$ = 0.200 Ω, $R_2$ = 0.150 Ω, $X_1 = X_2$ = 0.50 Ω and $X_m$ = 19.9 Ω, with 499 W of rotational loss.
:::
:::

::: example
## The same blocked-rotor data, but the motor is NEMA class B. How do the reactances split?

::: solution
1. **Stator leakage reactance.** Class B puts 40% of the 1.00 Ω in the stator:
   $$\begin{aligned} X_1 &= 0.4 \times 1.00 \\ &= 0.40\ \Omega \end{aligned}$$
   and $X_2$ = 0.60 Ω.
2. **Magnetizing reactance.**
   $$\begin{aligned} X_m &= 20.43 - 0.40 \\ &= 20.0\ \Omega \end{aligned}$$
3. **Why the split matters.** Class B rotors have deeper bars and more rotor leakage. The difference matters most for starting current and torque, which depend on $X_1 + X_2$ and how it divides around the magnetizing branch.

**Answer:** $X_1$ = 0.40 Ω, $X_2$ = 0.60 Ω and $X_m$ = 20.0 Ω.
:::
:::

::: example
## The 460 V motor's blocked-rotor test is repeated at 60 Hz instead of 15 Hz, and now gives $R_\text{br}$ = 0.42 Ω. What rotor resistance would that imply, and what would it do to the predicted full-load slip?

::: solution
1. **Implied rotor resistance.**
   $$\begin{aligned} R_2 &= 0.42 - 0.20 \\ &= 0.22\ \Omega \end{aligned}$$
   47% more than the 0.15 Ω measured at 15 Hz.
2. **Why it's higher.** At 60 Hz the rotor current crowds into the tops of the bars (lesson 25's deep-bar effect), raising their resistance, but in normal running the rotor current alternates at only a hertz or two and uses the whole bar.
3. **Effect on the prediction.** Since slip at a given torque is nearly proportional to $R_2$, the 60 Hz value would predict a full-load slip about 47% too high, and an efficiency too low.
4. **The standard test.** That's why the standard test uses a quarter of rated frequency.

**Answer:** it implies $R_2$ = 0.22 Ω, 47% too high, so it would predict a full-load slip about 47% too high.
:::
:::

::: check
given: V = 6 | 12 | 24; I = 10 | 30 | 60
answer: V/(2*I)
unit: Ω
tolerance: 0.5%

## A DC test applies {V} V between two terminals of a Y-connected stator and draws {I} A. What's $R_1$?

::: right
Right. Two phases in series: $V/(2I)$ = {answer} Ω.
:::

::: misses
- [V/I] The current flows through two phase windings in series.
- [any] Not yet. Line to line means two windings.
:::
:::

::: check
given: r = 300 | 800 | 2000; I = 8 | 15 | 40; R = 0.1 | 0.3; let P = r + 3*I^2*R
answer: P - 3*I^2*R
unit: W
tolerance: 0.5%

## On no load the motor draws {I} A and {P} W, with $R_1$ = {R} Ω. What's its rotational loss?

::: right
Right. $P_\text{nl} - 3I^2R_1$ = {answer} W.
:::

::: misses
- [P] Subtract the stator copper loss.
- [any] Not yet. Input less stator copper.
:::
:::

::: check
given: V = 230 | 460 | 575; I = 5 | 12 | 30
answer: V/sqrt(3)/I
unit: Ω
tolerance: 0.5%

## On no load at {V} V (line, Y) the motor draws {I} A. About what is $X_1 + X_m$?

::: right
Right. $V_\phi/I_\text{nl}$ = {answer} Ω.
:::

::: misses
- [V/I] Use the phase voltage.
- [any] Not yet. Phase voltage over no-load current.
:::
:::

::: check
given: I = 20 | 40 | 80; R = 0.05 | 0.2; r = 0.08 | 0.2 | 0.4; let P = 3*I^2*(R + r)
answer: P/(3*I^2) - R
unit: Ω
tolerance: 0.5%

## A blocked-rotor test draws {I} A and {P} W; $R_1$ = {R} Ω. What's $R_2$?

::: right
Right. $P/(3I^2) - R_1$ = {answer} Ω.
:::

::: misses
- [P/(3*I^2)] That's $R_1 + R_2$.
- [any] Not yet. The test resistance is $R_1 + R_2$.
:::
:::

::: check
given: I = 30 | 60; R = 0.15 | 0.3; X = 0.8 | 1.5 | 2.5; f = 15 | 20; let V = sqrt(3)*I*sqrt(R^2 + (X*f/60)^2)
answer: sqrt((V/sqrt(3)/I)^2 - R^2)*60/f
unit: Ω
tolerance: 0.5%

## At {f} Hz the blocked-rotor test needs {V} V (line, Y) for {I} A, and $R_1 + R_2$ = {R} Ω. What's $X_1 + X_2$ at 60 Hz?

::: right
Right. $\sqrt{|Z|^2 - R^2}$ at the test frequency, scaled by 60/{f}: {answer} Ω.
:::

::: misses
- [sqrt((V/sqrt(3)/I)^2 - R^2)] Scale the reactance up to 60 Hz.
- [any] Not yet. Reactance from |Z| and R, then scale with frequency.
:::
:::

::: check
given: X = 0.6 | 1.2 | 2; N = 20 | 35; c = 0.3 | 0.4 | 0.5
answer: N - c*X
unit: Ω
tolerance: 0.5%

## A motor's no-load reactance is {N} Ω and its total leakage reactance {X} Ω, of which the stator takes a fraction {c}. What's $X_m$?

::: right
Right. $X_\text{nl} - X_1$ = {answer} Ω.
:::

::: misses
- [N - X] Only the stator's share is in series with $X_m$ on no load.
- [any] Not yet. $X_m = X_\text{nl} - X_1$.
:::
:::

::: check
kind: parts
given: d = 6 | 10 | 24; c = 10 | 25 | 40; V = 230 | 460; I = 4 | 12 | 30; P = 200 | 500 | 1200

## A Y-connected motor's DC test reads {d} V at {c} A between two terminals; its no-load test at {V} V line takes {I} A and {P} W.

::: part
answer: d/(2*c)
unit: Ω
tolerance: 0.5%

### What is $R_1$?

::: misses
- [d/c] The DC test puts two phases in series.
- [any] $V_\text{dc}/(2I_\text{dc})$.
:::
:::

::: part
answer: V/sqrt(3)/I
unit: Ω
tolerance: 0.5%

### What is $X_1 + X_m$, approximately?

::: misses
- [V/I] Use the phase voltage.
- [any] $V_\phi/I_\text{nl}$.
:::
:::

::: part
answer: P - 3*I^2*d/(2*c)
unit: W
tolerance: 0.5%

### What is the rotational loss?

::: misses
- [any] $P_\text{nl} - 3I_\text{nl}^2R_1$.
:::
:::
:::

::: check
kind: derivation
vars: P = 10..10000, I = 1..200, V = 1..200, f = 5..60, F = 50..60

## A blocked-rotor test at f hertz takes P watts at I amperes per phase with phase voltage V; the motor is rated F hertz.

::: step
answer: P/(3*I^2)

### What is $R_1 + R_2$?
:::

::: step
answer: sqrt((V/I)^2 - (P/(3*I^2))^2)*F/f

### What is $X_1 + X_2$ at rated frequency?
:::

::: right
Right. Reactances scale with frequency, so the test value is scaled up to rated.
:::
:::

::: explain
## Why is the blocked-rotor test run at reduced frequency?

::: model
In normal running the rotor's currents alternate at slip frequency, a hertz or two, but on a blocked rotor at line frequency they'd alternate at 60 Hz. Rotor bars, especially the deep or double-cage bars of class B and C motors, behave very differently at those two frequencies: at 60 Hz the current crowds toward the top of each bar, raising its effective resistance and lowering its leakage inductance. Parameters measured at 60 Hz would describe the motor at starting, not at its operating point. Testing at about a quarter of rated frequency puts the rotor much closer to its running condition, and the reactance is simply scaled back up to rated frequency.
:::
:::

::: practice

::: check
given: V = 3 | 30; I = 5 | 80
answer: V/(2*I)
unit: Ω
tolerance: 0.5%

## $R_1$ from a DC test: {V} V, {I} A?

::: misses
- [any] $V/(2I)$.
:::
:::

::: check
given: I = 10 | 120; R = 0.02 | 0.4; r = 0.03 | 0.5; let P = 3*I^2*(R + r)
answer: P/(3*I^2) - R
unit: Ω
tolerance: 0.5%

## $R_2$: {P} W, {I} A, $R_1$ = {R} Ω?

::: misses
- [any] $P/(3I^2) - R_1$.
:::
:::

::: check
given: I = 20 | 90; R = 0.1 | 0.35; X = 0.5 | 3; f = 12 | 25; let V = sqrt(3)*I*sqrt(R^2 + (X*f/60)^2)
answer: sqrt((V/sqrt(3)/I)^2 - R^2)*60/f
unit: Ω
tolerance: 0.5%

## $X_1 + X_2$ at 60 Hz: {V} V line, {I} A, R = {R} Ω, {f} Hz test?

::: misses
- [any] $\sqrt{Z^2 - R^2} \times 60/f$.
:::
:::
:::