S12 Electric machines · Practice
Inverter-fed motors
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A drive's edges rise in 50 ns and its cable carries waves at 150 m/µs.
(a)
What is the critical cable length?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
Check
A drive with a 650 V bus feeds a 460 V motor over a long cable; the motor reflects with Γ = 0.8.
(a)
What peak voltage reaches the motor?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What percentage of an inverter-duty motor's 3.1 × rated limit is that?
Check
A motor's winding presents 300 Ω to a fast edge arriving on a cable of 30 Ω.
(a)
What is the reflection coefficient at the motor?
Check
A two-level drive on a 650 V bus feeds a motor whose bearing voltage ratio is 2%.
(a)
By how much does the common-mode voltage step at each switching?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
How large are the steps across the bearings?
Check
An inverter's 650 V edges rise in 20 ns.
(a)
What is the dv/dt?
Write units the way you normally would: 1.5 kV/µs, 1500 V/µs and 0.0015 MV/µs are the same answer.
Check
Critical length: 30 ns rise, 160 m/µs?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
Check
Peak at the motor: 560 V bus, Γ = 0.85, long cable?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Bearing voltage steps: 600 V bus, ratio 3%?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12