title: Losses, heating and ratings
heading: Where a machine's losses come from, efficiency and the energy cost of a few percent, measuring winding temperature by resistance, insulation classes and the halving of insulation life every 10 K, thermal time constants, and rating a motor for an intermittent duty cycle by its RMS torque
eyebrow: S12 · Lesson 46 · Losses, heating and ratings
xp: 50
---

::: hook
A motor's nameplate rating isn't a property of its electromagnetics. The same machine could deliver much more torque for a few seconds; what limits it is heat. Losses raise the temperature of the windings until their insulation degrades, and insulation ages roughly twice as fast for every 10 K it runs hotter. Ratings, efficiency standards and the choice of a motor for a duty cycle all follow from that chain: losses, temperature, insulation life.
:::

::: play
- Expected insulation life against winding hot-spot temperature, using the rule that life halves for every 10 K (log scale), for an insulation class rated for 20,000 hours at its class temperature.
- Running 10 K over the class temperature halves the life; running 10 K under doubles it.
- Choose the class: B (130 °C), F (155 °C) or H (180 °C). Many motors use class F insulation but are designed for class B temperature rise, for a large margin.
:::

```sim plot
view: graph
x: T = 90..200 °C
y: L = 100..10000000 h log
slider: c = 130..180 step 25 = 155 °C
plot: 20000*2^((c - T)/10) | samples: 300 | label: insulation life
marker: x = c
readout: life at 10 K below class, h = 20000*2 | digits: 3
```

::: predict
## A motor normally runs its windings at 120 °C. A blocked cooling fan raises them to 140 °C. What happens to its expected insulation life?

- [ ] It falls by 17%, in proportion to temperature
- [ ] It halves
- [x] It falls to a quarter
- [ ] Nothing, as long as it stays below 155 °C

::: reveal
By the 10 K rule, each 10 K halves the life, so 20 K divides it by 4. The rule is approximate (it comes from the Arrhenius law of B11, with the activation energy of typical insulation), but it explains why ratings and temperature limits are taken so seriously.
:::
:::

::: nameit
## Losses

- **Stator copper** $3I_1^2R_1$ and **rotor copper** ($sP_\text{ag}$ in an induction machine), growing with load squared.
- **Core loss**, hysteresis and eddy currents (lesson 2), nearly constant at fixed voltage and frequency.
- **Friction and windage**, nearly constant at fixed speed.
- **Stray load loss**, from leakage fields and harmonics, roughly 0.5 to 2% of output, also growing with load.

Efficiency is output over output plus all losses. Standards (IEC 60034-30-1's IE1 to IE4 classes, NEMA Premium) set minimum efficiencies by rating and pole count.

## Temperature

Winding temperature is measured by the rise in its copper resistance:

$$T_2 = \frac{R_2}{R_1}(234.5 + T_1) - 234.5$$

The machine heats roughly as a first-order system, $\Delta T(t) = \Delta T_\text{ss}(1 - e^{-t/\tau_\text{th}})$, with a thermal time constant of minutes to hours.

## Insulation and life

Insulation classes set the maximum hot-spot temperature: B 130 °C, F 155 °C, H 180 °C. Life roughly halves for every 10 K above it: relative life $2^{(T_\text{class} - T)/10}$.

## Duty cycles

For a load that varies faster than the thermal time constant, copper loss follows the square of current, roughly the square of torque, so a motor is sized by the **RMS torque** over the cycle, $T_\text{rms} = \sqrt{\sum T_k^2t_k/\sum t_k}$, with its peak torque checked separately against the breakdown or current limit.
:::

::: example
## A winding's resistance rises from its 25 °C value by a factor of 1.32 after a heat run. What's its average temperature?

::: solution
1. **Average temperature.**
   $$\begin{aligned} T_2 &= 1.32 \times (234.5 + 25) \\ &\quad - 234.5 \\ &= 108.0\ \text{°C} \end{aligned}$$
2. **Hot spot.** The hot spot, usually 5 to 15 K above the average, is what the insulation class limits.

**Answer:** the winding averages 108.0 °C.
:::
:::

::: example
## An 11 kW motor runs at 75% load for 6000 hours a year. How much energy does raising its efficiency from 90% to 93% save?

::: solution
1. **Energy out.** Output 8.25 kW for 6000 h is 49,500 kWh.
2. **Energy saved.**
   $$\begin{aligned} \Delta W &= \frac{49\,500}{0.90} - \frac{49\,500}{0.93} \\ &= 1774\ \text{kWh} \end{aligned}$$
   a year, about 266 dollars at 15 cents per kWh.
3. **Over the motor's life.** Over a 15-year life the saving is several times the price difference between efficiency classes.

**Answer:** it saves 1774 kWh a year, about 266 dollars.
:::
:::

::: example
## A motor's duty cycle repeats every minute: 40 N·m for 10 s, 15 N·m for 20 s and 5 N·m for 30 s. What continuous torque rating does it need?

::: solution
1. **Why RMS torque.** Copper loss follows torque squared, so the motor heats as if it carried the RMS torque continuously.
2. **Mean square torque.**
   $$\begin{aligned} T_\text{rms}^2 &= (40^2 \times 10 + 15^2 \times 20 \\ &\quad + 5^2 \times 30)/60 \\ &= 354 \end{aligned}$$
3. **RMS torque.**
   $$\begin{aligned} T_\text{rms} &= \sqrt{354} \\ &= 18.8\ \text{N·m} \end{aligned}$$
4. **Rating.** A motor rated about 19 N·m continuous will run at its rated temperature, provided the one-minute cycle is much shorter than its thermal time constant and its peak torque, at least 40 N·m, is comfortably below breakdown.
5. **Sizing by the peak.** Sizing by the 40 N·m peak would buy a motor twice as large.

**Answer:** about 19 N·m continuous, since the RMS torque is 18.8 N·m, as long as the motor can also deliver the 40 N·m peak.
:::
:::

::: check
given: r = 1.15 | 1.3 | 1.45; T = 20 | 25
answer: r*(234.5 + T) - 234.5
unit: °C
tolerance: 0.5%

## A copper winding's resistance is {r} times its value at {T} °C. What's its temperature?

::: right
Right. $(R_2/R_1)(234.5 + T_1) - 234.5$ = {answer} °C.
:::

::: misses
- [r*T] Copper's resistance is proportional to temperature plus 234.5, not to temperature.
- [any] Not yet. Copper's inferred zero-resistance temperature is −234.5 °C.
:::
:::

::: check
given: d = 5 | 10 | 20 | 30
answer: 2^(-d/10)
tolerance: 0.5%

## A winding runs {d} K hotter than before. By what factor does its expected insulation life change?

::: right
Right. $2^{-\Delta T/10}$ = {answer}.
:::

::: misses
- [1 - d/100] Life falls exponentially with temperature: by half for every 10 K.
- [any] Not yet. Halves every 10 K.
:::
:::

::: check
given: a = 80 | 150 | 300; t = 5 | 15; b = 20 | 50; u = 30 | 60
answer: sqrt((a^2*t + b^2*u)/(t + u))
unit: N·m
tolerance: 0.5%

## A motor's duty cycle is {a} N·m for {t} s, then {b} N·m for {u} s, repeating. What continuous torque rating does it need, thermally?

::: right
Right. $\sqrt{\sum T^2t/\sum t}$ = {answer} N·m.
:::

::: misses
- [(a*t + b*u)/(t + u)] Heating follows torque squared: use the RMS, not the average.
- [any] Not yet. The RMS torque.
:::
:::

::: check
given: P = 5 | 30 | 110; x = 0.6 | 0.9; h = 2000 | 8000; e = 0.88 | 0.92; f = 0.02 | 0.03
answer: P*x*h*(1/e - 1/(e + f))
unit: kWh
tolerance: 0.5%

## A {P} kW motor runs at {x} load for {h} hours a year. Its efficiency rises from {e} by {f}. How much energy is saved per year?

::: right
Right. Output energy × $(1/\eta_1 - 1/\eta_2)$ = {answer} kWh.
:::

::: misses
- [P*x*h*f] The saving is in input energy, $P/\eta$, not output times the efficiency gain.
- [any] Not yet. Compare input energy at the two efficiencies.
:::
:::

::: check
given: P = 5 | 50 | 250; c = 2 | 4; r = 1 | 3; s = 0.5 | 1.5
answer: 100*P/(P*(1 + (c + r + s)/100))
unit: %
tolerance: 0.5%

## A {P} kW motor's losses are {c}% (stator and rotor copper), {r}% (core, friction, windage) and {s}% (stray), all as percentages of output. What's its efficiency?

::: right
Right. Output over output plus losses: {answer}%.
:::

::: misses
- [any] Not yet. $P/(P + \sum L)$.
:::
:::

::: check
given: d = 40 | 80 | 105; t = 10 | 30 | 60; u = 20 | 45
answer: d*(1 - exp(-t/u))
unit: K
tolerance: 0.5%

## A motor's steady temperature rise at its load is {d} K and its thermal time constant {u} min. How much has it risen after {t} min from cold?

::: right
Right. $\Delta T_\text{ss}(1 - e^{-t/\tau})$ = {answer} K.
:::

::: misses
- [d*t/u] Heating slows as the temperature approaches its final value.
- [any] Not yet. First-order heating.
:::
:::

::: check
kind: parts
given: c = 130 | 155 | 180; T = 120 | 140 | 165 | 195; k = 1.25 | 1.35; a = 20 | 25

## A winding's resistance rises by a factor of {k} from its value at {a} °C. Its insulation is rated {c} °C; separately, consider a hot spot of {T} °C.

::: part
answer: k*(234.5 + a) - 234.5
unit: °C
tolerance: 0.5%

### What is the winding's average temperature?

::: misses
- [any] $(R_2/R_1)(234.5 + T_1) - 234.5$.
:::
:::

::: part
answer: 2^((c - T)/10)
tolerance: 0.5%

### What relative life does a {T} °C hot spot give the insulation?

::: misses
- [any] $2^{(T_\text{class} - T)/10}$.
:::
:::
:::

::: check
kind: derivation
vars: a = 1..500, t = 0.1..100, b = 0..500, u = 0.1..100

## A motor carries torque a for t seconds, then b for u seconds, repeatedly.

::: step
answer: sqrt((a^2*t + b^2*u)/(t + u))

### What is its RMS torque?
:::

::: step
answer: (a*t + b*u)/(t + u)

### What is its average torque?
:::

::: right
Right. Heating follows the RMS, always at least the average, so peaky duty needs a larger motor than the average suggests.
:::
:::

::: explain
## Why is a motor for an intermittent load sized by RMS torque rather than peak or average torque?

::: model
What limits a motor's continuous rating is the temperature of its windings, and that's set by the average power lost, mainly copper loss, which grows with the square of current and so roughly with the square of torque. When the load cycles faster than the motor's thermal time constant, the windings respond to the time average of that loss, which is proportional to the mean of the squared torque: the RMS torque squared. An average of the torque itself would understate the heating, since the peaks contribute disproportionately. The peak torque still has to be checked separately, against the motor's breakdown torque or the drive's current limit, since it's an instantaneous constraint and not a thermal one.
:::
:::

::: practice

::: check
given: r = 1.1 | 1.5; T = 15 | 30
answer: r*(234.5 + T) - 234.5
unit: °C
tolerance: 0.5%

## Temperature: R ratio {r}, from {T} °C?

::: misses
- [any] $r(234.5 + T) - 234.5$.
:::
:::

::: check
given: a = 50 | 500; t = 2 | 20; b = 10 | 100; u = 10 | 80
answer: sqrt((a^2*t + b^2*u)/(t + u))
unit: N·m
tolerance: 0.5%

## RMS torque: {a} N·m for {t} s, {b} N·m for {u} s?

::: misses
- [any] $\sqrt{\sum T^2t/\sum t}$.
:::
:::

::: check
given: d = 3 | 5 | 8 | 10 | 15 | 20 | 25
answer: 2^(-d/10)
tolerance: 0.5%

## Life factor for {d} K hotter?

::: misses
- [any] $2^{-\Delta T/10}$.
:::
:::
:::