S12 · Lesson 12 · Machine sizing and scaling
Electric and magnetic loading, the shear stress they produce, the output equation that sizes a rotor from its torque, turns from the voltage, and how torque, losses, temperature and efficiency scale with size
Lesson 9 sized a machine from a single number, the shear stress on its rotor surface. That number isn't arbitrary: it's the product of how much flux the iron can carry and how much current the slots can hold before the copper overheats. Those two limits, the magnetic and electric loadings, set the size of every motor and generator, and they explain why a large machine is more efficient than a small one, and why it needs better cooling.
- The curve is the torque a machine with a square rotor (length equal to diameter) can make against its rotor diameter, , for the shear stress set by the loadings on the sliders: .
- Torque grows as the cube of the diameter at fixed loadings: doubling the size gives eight times the torque.
- Raising either loading raises the torque in proportion, until saturation (B) or heating (A) stops it.
Predict
Two motors are built alike in every proportion, one twice the other's linear size, with the same current density and flux density. How do their torques compare?
Rotor volume grows 8 times, and the slots, twice as deep, hold twice the current per meter of rotor surface at the same current density, so the shear stress doubles too: 16 times the torque from 8 times the material. But the copper loss also grows 8 times while the surface that sheds heat grows only 4 times, so the large motor runs hotter and must use a lower current density or better cooling.
Name it
Loadings
- Magnetic loading: the peak air-gap flux density , about 0.7 to 1 T, limited by the teeth saturating.
- Electric loading: the RMS current per meter of gap circumference, A (all phases' conductors together), about 20 to 60 kA/m in air-cooled machines and more with liquid cooling, limited by the heat the copper makes.
With the current wave aligned to the flux wave, the average tangential force per unit area is
The output equation
From lesson 9, torque is twice the shear stress times the rotor volume, so for rotor diameter D and length l,
Designers usually choose a length-to-diameter ratio between about 0.5 and 2, then D from the required torque.
Turns from voltage
The flux per pole follows from the loading, with r = D/2 (lesson 9), and the series turns per phase from the voltage, .
Scaling
Scale every dimension by k at fixed flux and current densities: torque grows as (volume times shear stress ), mass and losses as , cooling surface as . So:
- temperature rise grows as k, unless the current density falls as ;
- losses as a fraction of power fall as 1/k, so large machines are more efficient;
- torque per kilogram grows with size.
Worked example
Size a 55 kW, 4-pole motor running at 1480 rpm, with a shear stress of 25 kPa and a rotor as long as it is wide.
Show the solution
- Torque.
- Rotor volume.
- Diameter. With l = D, gives
- Compare with catalogs. Catalog motors of this rating, with frame 250 and a rotor about 0.2 m across, agree. The stator's outer diameter is typically 1.5 to 1.8 times the rotor's.
Answer a rotor 0.208 m across and 0.208 m long.
Worked example
What shear stress do 40 kA/m of electric loading and 0.9 T peak gap flux density give, and what turns per phase does the 55 kW motor need for 400 V line to line at 50 Hz, with = 0.93?
Show the solution
- Shear stress. close to the 25 kPa assumed.
- Flux per pole.
- Turns per phase. For 230.9 V per phase in Y:
- Rounding. The induced voltage is a little below the terminal voltage in a motor, so the final design rounds to the nearest slot-compatible number.
Answer a shear stress of 25.5 kPa, and about 57 turns per phase.
Worked example
A motor design is scaled up by 2 in every dimension. If it must run no hotter, by how much can its torque grow?
Show the solution
- At the same current density. The torque would grow 16 times, the copper loss 8 times and the cooling surface 4 times, so the temperature rise would double.
- Holding the rise. The copper loss per unit surface must come back down by half. Since loss goes as the square of current density, the current density falls by .
- Torque. Torque is proportional to current density, so it grows times instead.
- Large machines. Large machines therefore run at lower current densities, or with forced air, hydrogen or water cooling.
Answer the torque can grow 11.3 times, against 16 times at the same current density.
Check
A machine has an electric loading of 40 kA/m and a peak gap flux density of 0.7 T.
(a)
What shear stress can it develop?
Write units the way you normally would: 1.5 kPa, 1500 Pa and 0.0015 MPa are the same answer.
Check
A 30 kW machine runs at 900 rpm with a shear stress of 40 kPa and a length-to-diameter ratio of 1.5.
(a)
What torque must it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What rotor diameter does it need?
Check
A 6-pole machine has a rotor 0.15 m in diameter and 1 times as long, with a 0.8 T peak gap field, and must generate 400 V per phase at 50 Hz with = 0.95.
(a)
What is its flux per pole?
Write units the way you normally would: 1.5 Wb, 1500 mWb and 0.0015 kWb are the same answer.
(b)
How many series turns per phase (before rounding)?
Check
A machine is scaled by 2 in every dimension at the same current and flux densities.
(a)
By what factor does its torque grow?
(b)
By what factor does its temperature rise grow?
(c)
If its current density is cut to hold the temperature rise, by what factor does its torque grow?
Check
A motor loses 4% of its rated power. A geometrically similar motor of 16 times the torque is built at the same speed and loadings.
(a)
By what factor is it larger in linear size?
(b)
What percentage of its power does it lose?
Check
Why do large generators use hydrogen or water cooling while small motors manage with a fan?
Check
A machine has electric loading A (A/m), peak gap field B, rotor diameter D, length rD, turning at n rpm.
Step 1
What is its shear stress?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What torque does it make?
Step 3
What power?
Check
Write size_machine(P, n, sigma, ratio) returning (torque, D, l) for power P (W) at n rpm, shear stress sigma (Pa) and length l = ratio·D, and turns(E, f, kw, poles, B, D, l): series turns per phase (unrounded).
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why is the size of a motor set mainly by its torque rather than its power?
The force a machine can exert on its rotor surface is limited by the flux density the iron can carry and the current the slots can hold without overheating, and those limits don't depend on speed. Torque is that force per unit area times the rotor's surface area times its radius, so for given loadings it is fixed by the rotor's volume. Power is torque times speed, so a machine of a given size can deliver more power by running faster. That's why high-speed motors are small for their power and low-speed machines, like direct-drive wind generators, are very large.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.