title: Machine sizing and scaling
heading: Electric and magnetic loading, the shear stress they produce, the output equation that sizes a rotor from its torque, turns from the voltage, and how torque, losses, temperature and efficiency scale with size
eyebrow: S12 · Lesson 12 · Machine sizing and scaling
xp: 50
---

::: hook
Lesson 9 sized a machine from a single number, the shear stress on its rotor surface. That number isn't arbitrary: it's the product of how much flux the iron can carry and how much current the slots can hold before the copper overheats. Those two limits, the magnetic and electric loadings, set the size of every motor and generator, and they explain why a large machine is more efficient than a small one, and why it needs better cooling.
:::

::: play
- The curve is the torque a machine with a square rotor (length equal to diameter) can make against its rotor diameter, $T = \sigma\pi D^2l/2$, for the shear stress set by the loadings on the sliders: $\sigma = A\hat B/\sqrt2$.
- Torque grows as the cube of the diameter at fixed loadings: doubling the size gives eight times the torque.
- Raising either loading raises the torque in proportion, until saturation (B) or heating (A) stops it.
:::

```sim plot
view: graph
x: D = 0.05..0.6
y: T = 0..20000
slider: A = 10..100 = 40
slider: B = 0.5..1.1 = 0.9
plot: A*1e3*B/sqrt(2)*pi*D^3/2 | label: torque, N·m (A in kA/m, B in T)
```

::: predict
## Two motors are built alike in every proportion, one twice the other's linear size, with the same current density and flux density. How do their torques compare?

- [ ] 4 times
- [ ] 8 times
- [x] 16 times
- [ ] 2 times

::: reveal
Rotor volume grows 8 times, and the slots, twice as deep, hold twice the current per meter of rotor surface at the same current density, so the shear stress doubles too: 16 times the torque from 8 times the material. But the copper loss also grows 8 times while the surface that sheds heat grows only 4 times, so the large motor runs hotter and must use a lower current density or better cooling.
:::
:::

::: nameit
## Loadings

- **Magnetic loading**: the peak air-gap flux density $\hat B$, about 0.7 to 1 T, limited by the teeth saturating.
- **Electric loading**: the RMS current per meter of gap circumference, A (all phases' conductors together), about 20 to 60 kA/m in air-cooled machines and more with liquid cooling, limited by the heat the copper makes.

With the current wave aligned to the flux wave, the average tangential force per unit area is
$$\sigma = \frac{A\hat B}{\sqrt2}$$

## The output equation

From lesson 9, torque is twice the shear stress times the rotor volume, so for rotor diameter D and length l,
$$T = \frac{\pi}{2}\sigma D^2l, \qquad P = T\omega_m$$
Designers usually choose a length-to-diameter ratio between about 0.5 and 2, then D from the required torque.

## Turns from voltage

The flux per pole follows from the loading, $\Phi_p = \frac{4}{P}\hat Blr$ with r = D/2 (lesson 9), and the series turns per phase from the voltage, $N_\text{ph} = E/(\sqrt2\pi fk_w\Phi_p)$.

## Scaling

Scale every dimension by k at fixed flux and current densities: torque grows as $k^4$ (volume $k^3$ times shear stress $\propto k$), mass and losses as $k^3$, cooling surface as $k^2$. So:
- temperature rise grows as k, unless the current density falls as $1/\sqrt k$;
- losses as a fraction of power fall as 1/k, so large machines are more efficient;
- torque per kilogram grows with size.
:::

::: example
## Size a 55 kW, 4-pole motor running at 1480 rpm, with a shear stress of 25 kPa and a rotor as long as it is wide.

::: solution
1. **Torque.**
   $$\begin{aligned} T &= \frac{55\,000}{1480 \times 2\pi/60} \\ &= 354.9\ \text{N·m} \end{aligned}$$
2. **Rotor volume.**
   $$\begin{aligned} V_r &= \frac{T}{2\sigma} \\ &= \frac{354.9}{50\,000} \\ &= 7.10 \times 10^{-3}\ \text{m}^3 \end{aligned}$$
3. **Diameter.** With l = D, $\pi D^3/4 = 7.10 \times 10^{-3}$ gives
   $$D = 0.208\ \text{m}$$
4. **Compare with catalogs.** Catalog motors of this rating, with frame 250 and a rotor about 0.2 m across, agree. The stator's outer diameter is typically 1.5 to 1.8 times the rotor's.

**Answer:** a rotor 0.208 m across and 0.208 m long.
:::
:::

::: example
## What shear stress do 40 kA/m of electric loading and 0.9 T peak gap flux density give, and what turns per phase does the 55 kW motor need for 400 V line to line at 50 Hz, with $k_w$ = 0.93?

::: solution
1. **Shear stress.**
   $$\begin{aligned} \sigma &= \frac{40\,000 \times 0.9}{\sqrt2} \\ &= 25.5\ \text{kPa} \end{aligned}$$
   close to the 25 kPa assumed.
2. **Flux per pole.**
   $$\begin{aligned} \Phi_p &= \tfrac44 \times 0.9 \times 0.208 \times 0.104 \\ &= 0.0195\ \text{Wb} \end{aligned}$$
3. **Turns per phase.** For 230.9 V per phase in Y:
   $$\begin{aligned} N_\text{ph} &= \frac{230.9}{4.443 \times 50 \times 0.93 \times 0.0195} \\ &= 57\ \text{turns} \end{aligned}$$
4. **Rounding.** The induced voltage is a little below the terminal voltage in a motor, so the final design rounds to the nearest slot-compatible number.

**Answer:** a shear stress of 25.5 kPa, and about 57 turns per phase.
:::
:::

::: example
## A motor design is scaled up by 2 in every dimension. If it must run no hotter, by how much can its torque grow?

::: solution
1. **At the same current density.** The torque would grow 16 times, the copper loss 8 times and the cooling surface 4 times, so the temperature rise would double.
2. **Holding the rise.** The copper loss per unit surface must come back down by half. Since loss goes as the square of current density, the current density falls by $1/\sqrt2$.
3. **Torque.** Torque is proportional to current density, so it grows
   $$\frac{16}{\sqrt2} = 11.3$$
   times instead.
4. **Large machines.** Large machines therefore run at lower current densities, or with forced air, hydrogen or water cooling.

**Answer:** the torque can grow 11.3 times, against 16 times at the same current density.
:::
:::

::: check
kind: parts
given: A = 20 | 40 | 60; B = 0.7 | 0.85 | 1

## A machine has an electric loading of {A} kA/m and a peak gap flux density of {B} T.

::: part
answer: A*1e3*B/sqrt(2)/1e3
unit: kPa
tolerance: 0.5%

### What shear stress can it develop?

::: misses
- [A*B] Use the peak current, $\sqrt2A$, times the peak field, halved.
- [any] $A\hat B/\sqrt2$.
:::
:::
:::

::: check
kind: parts
given: P = 5 | 30 | 200; n = 900 | 1500 | 3000; s = 15 | 25 | 40; r = 0.8 | 1.5

## A {P} kW machine runs at {n} rpm with a shear stress of {s} kPa and a length-to-diameter ratio of {r}.

::: part
answer: P*1e3/(n*2*pi/60)
unit: N·m
tolerance: 0.5%

### What torque must it make?

::: misses
- [any] $P/\omega_m$.
:::
:::

::: part
answer: (2*P*1e3/(n*2*pi/60)/(pi*s*1e3*r))^(1/3)
unit: m
tolerance: 0.5%

### What rotor diameter does it need?

::: misses
- [(P*1e3/(n*2*pi/60)/(pi*s*1e3*r))^(1/3)] The torque is $\frac\pi2\sigma D^2l$: twice the shear stress times the volume.
- [any] Solve $T = \frac\pi2\sigma D^3r$.
:::
:::
:::

::: check
kind: parts
given: E = 230 | 400 | 3800; f = 50 | 60; k = 0.92 | 0.95; P = 2 | 4 | 6; B = 0.8 | 0.95; D = 0.15 | 0.4; r = 1 | 1.5

## A {P}-pole machine has a rotor {D} m in diameter and {r} times as long, with a {B} T peak gap field, and must generate {E} V per phase at {f} Hz with $k_w$ = {k}.

::: part
answer: 4/P*B*r*D*D/2
unit: Wb
tolerance: 0.5%

### What is its flux per pole?

::: misses
- [any] $\frac4P\hat Blr$.
:::
:::

::: part
answer: E/(sqrt(2)*pi*f*k*4/P*B*r*D*D/2)
unit: turns
tolerance: 0.5%

### How many series turns per phase (before rounding)?

::: misses
- [any] $E/(\sqrt2\pi fk_w\Phi_p)$.
:::
:::
:::

::: check
kind: parts
given: k = 1.5 | 2 | 3

## A machine is scaled by {k} in every dimension at the same current and flux densities.

::: part
answer: k^4
tolerance: 0.5%

### By what factor does its torque grow?

::: misses
- [k^3] The shear stress grows too, with the slot depth.
- [any] Volume times shear stress: $k^3 \cdot k$.
:::
:::

::: part
answer: k
tolerance: 0.5%

### By what factor does its temperature rise grow?

::: misses
- [any] Loss $k^3$ over surface $k^2$.
:::
:::

::: part
answer: k^4/sqrt(k)
tolerance: 0.5%

### If its current density is cut to hold the temperature rise, by what factor does its torque grow?

::: misses
- [any] Current density falls as $1/\sqrt k$.
:::
:::
:::

::: check
kind: parts
given: p = 2 | 4 | 6; m = 16 | 81 | 256

## A motor loses {p}% of its rated power. A geometrically similar motor of {m} times the torque is built at the same speed and loadings.

::: part
answer: m^(1/4)
tolerance: 0.5%

### By what factor is it larger in linear size?

::: misses
- [any] Torque grows as $k^4$.
:::
:::

::: part
answer: p/m^(1/4)
unit: %
tolerance: 0.5%

### What percentage of its power does it lose?

::: misses
- [any] Losses grow as $k^3$, power as $k^4$.
:::
:::
:::

::: check
kind: choice

## Why do large generators use hydrogen or water cooling while small motors manage with a fan?

- [ ] Large generators run at higher voltage
- [x] Losses grow with volume while the surface that sheds heat grows only with area, so a larger machine at the same loadings makes more heat per unit of surface, and needs a much better coolant to keep its loadings up
- [ ] Hydrogen insulates better
- [ ] Large machines have higher current density

::: misses
- [1] Voltage doesn't set the cooling need.
- [3] Hydrogen is used for its heat transfer and low windage.
- [4] They usually have lower current density, for the same reason.
:::
:::

::: check
kind: derivation
vars: A = 5000..150000, B = 0.3..1.2, D = 0.02..2, r = 0.3..3, n = 100..30000

## A machine has electric loading A (A/m), peak gap field B, rotor diameter D, length rD, turning at n rpm.

::: step
answer: A*B/sqrt(2)

### What is its shear stress?
:::

::: step
answer: pi/2*A*B/sqrt(2)*D^3*r

### What torque does it make?
:::

::: step
answer: pi/2*A*B/sqrt(2)*D^3*r*2*pi*n/60

### What power?
:::

::: right
Right. Torque is set by size and loadings; speed multiplies it into power.
:::
:::

::: check
kind: python

## Write `size_machine(P, n, sigma, ratio)` returning (torque, D, l) for power P (W) at n rpm, shear stress sigma (Pa) and length l = ratio·D, and `turns(E, f, kw, poles, B, D, l)`: series turns per phase (unrounded).

```python starter
def size_machine(P, n, sigma, ratio):
    return 0.0, 0.0, 0.0

def turns(E, f, kw, poles, B, D, l):
    return 0.0
```

```python solution
import math

def size_machine(P, n, sigma, ratio):
    T = P / (n * 2 * math.pi / 60)
    D = (2 * T / (math.pi * sigma * ratio)) ** (1 / 3)
    return T, D, ratio * D

def turns(E, f, kw, poles, B, D, l):
    phi = 4 / poles * B * l * D / 2
    return E / (math.sqrt(2) * math.pi * f * kw * phi)
```

```python tests
import math
T, D, l = size_machine(55e3, 1480, 25e3, 1.0)
assert abs(T - 354.87) < 0.01 and abs(D - 0.2083) < 0.0005, "The 55 kW example: 355 N·m and 0.208 m."
assert abs(math.pi / 2 * 25e3 * D ** 2 * l - T) < 1e-6, "The output equation holds."
N = turns(400 / math.sqrt(3), 50, 0.93, 4, 0.9, D, l)
assert abs(N - 57.2) < 0.1, "About 57 turns per phase."
T2, D2, l2 = size_machine(55e3, 2960, 25e3, 1.0)
assert abs(D2 / D - 0.5 ** (1 / 3)) < 1e-9, "Twice the speed: half the torque, and a diameter smaller by the cube root of 2."
```

::: right
Right. A real design iterates: the slot and tooth dimensions, the losses and the temperature then refine the loadings, and the sizing runs again.
:::
:::

::: explain
## Why is the size of a motor set mainly by its torque rather than its power?

::: model
The force a machine can exert on its rotor surface is limited by the flux density the iron can carry and the current the slots can hold without overheating, and those limits don't depend on speed. Torque is that force per unit area times the rotor's surface area times its radius, so for given loadings it is fixed by the rotor's volume. Power is torque times speed, so a machine of a given size can deliver more power by running faster. That's why high-speed motors are small for their power and low-speed machines, like direct-drive wind generators, are very large.
:::
:::

::: practice
::: check
given: A = 25 | 50; B = 0.75 | 0.95
answer: A*1e3*B/sqrt(2)/1e3
unit: kPa
tolerance: 0.5%

## Shear stress at {A} kA/m and {B} T?

::: misses
- [any] $A\hat B/\sqrt2$.
:::
:::

::: check
given: T = 50 | 500 | 5000; s = 20 | 35; r = 1 | 2
answer: (2*T/(pi*s*1e3*r))^(1/3)
unit: m
tolerance: 0.5%

## Rotor diameter: {T} N·m, {s} kPa, l/D = {r}?

::: misses
- [any] $T = \frac\pi2\sigma D^3(l/D)$.
:::
:::

::: check
given: k = 0.5 | 0.8 | 1.2 | 1.5 | 2 | 2.5
answer: k^4
tolerance: 0.5%

## Torque ratio for scaling {k}, same densities?

::: misses
- [any] $k^4$.
:::
:::
:::