S1230 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S12 · Lesson 30 · Motion and loads

The equation of motion for a drive, acceleration time and stored energy, inertia and torque reflected through gears and screws, the gear ratio that accelerates a load fastest, constant-torque, fan and constant-power loads, and where motor and load curves cross stably

A motor never turns alone. It drives a fan, a conveyor, a hoist or a robot arm through gears or belts, and what the motor must supply depends as much on the load as on itself: how much inertia it must accelerate, how the load's torque changes with speed, and how the gearing transforms both. Getting this right decides whether a drive starts in time, whether it overheats on a duty cycle, and how much energy it can recover when braking.

  • The curves are lesson 23's 460 V motor's torque against speed and a fan load's torque, TL=kω2, scaled by the slider so that it needs the given torque at 1764 rpm.
  • The motor settles where the curves cross; between standstill and that point, the gap between them is the torque available to accelerate the inertia.
  • A heavier fan crosses at a slightly lower speed, with more slip.

Predict

A motor of inertia Jm drives a load of inertia JL through a gearbox. Which gear ratio accelerates the load fastest for a given motor torque?

Name it

The equation of motion

For a drive with total inertia J at the motor shaft, motor torque Te, load torque TL and viscous friction B,

Jdωdt=Te−TL−Bω

With a constant net torque, the time to change speed by Δω is JΔω/(Te−TL), and the rotating parts store 12Jω2, which a regenerative drive can return when braking.

Gears, belts and screws

Through a gearbox of ratio n (motor speed over load speed), a load torque TL appears at the motor as TL/n and a load inertia JL as JL/n2. A mass m moved by a screw of lead p per revolution, or a pulley of radius r, appears as m(p/2π)2 or mr2. The load accelerates fastest for a given motor torque when n=JL/Jm.

Load types

  • Constant torque: conveyors, hoists, positive-displacement pumps. Power grows with speed.
  • Fans and centrifugal pumps: torque grows as speed squared and power as its cube (the affinity laws), so running at 80% speed takes about half the power.
  • Constant power: winders and machine-tool spindles, where torque falls as speed rises.

Stable operation

The drive settles where Te=TL. That point is stable if a small speed increase makes the load torque exceed the motor's: dTL/dω>dTe/dω. On an induction motor's normal side, where its torque falls with speed, any rising or constant load is stable.

Worked example

A motor (0.05 kg·m²) drives a flywheel (0.5 kg·m²) with a constant 40 N·m, against 2 N·m of friction. How long does it take to reach 1500 rpm, and how much energy does it store?

Show the solution
  1. Target speed. 1500 rpm is 157.1 rad/s.
  2. Run-up time. With 38 N·m accelerating 0.55 kg·m², t=0.55×157.138=2.27s
  3. Stored energy. W=12×0.55×157.12=6.79kJ which a regenerative drive could largely return to its DC link in stopping, or a resistor must burn.

Answer it reaches 1500 rpm after 2.27 s and stores 6.79 kJ.

Worked example

A servo motor of 2×10−4 kg·m² drives a 0.02 kg·m² load through a gearbox. Compare the load's acceleration per newton-meter of motor torque at ratios of 5, 10 and 20.

Show the solution
  1. Ratio 10. The reflected load inertia is 0.02/100=2×10−4 kg·m², equal to the motor's, so the motor accelerates at αm=14×10−4=2500rad/s2 per N·m, and the load at a tenth of that, 250 rad/s².
  2. Ratio 5. The total inertia is 10−3, giving 1000 rad/s² at the motor and 200 at the load.
  3. Ratio 20. The total is 2.5×10−4, giving 4000 at the motor and again 200 at the load.
  4. Best ratio. The inertia match, JL/Jm = 10, is best.

Answer per newton-meter, the load accelerates at 200 rad/s² with a ratio of 5, 250 rad/s² with 10, and 200 rad/s² with 20, so the inertia-matched ratio of 10 is best.

Worked example

Lesson 23's motor (460 V, 4 poles) drives a fan that needs 133 N·m at 1764 rpm, with 1.0 kg·m² of total inertia. Where does it settle, and how long does it take to get within 5% of that speed?

Show the solution
  1. Where it settles. The fan's torque is 133(ω/184.7)2. The motor's curve crosses it at 184.7 rad/s, 1764 rpm, by design.
  2. Run-up time. Integrate Jdωdt=Te(ω)−TL(ω) from rest with the Thévenin torque formula: the drive passes 95% of that speed after 0.81 s.
  3. With twice the inertia. It takes 1.61 s, twice as long, since the torques along the way are unchanged.
  4. Starting heat. During that time the motor draws several times its rated current, so heavy inertia loads are limited by starting heat.

Answer it settles at 184.7 rad/s (1764 rpm) and gets within 5% of that speed after 0.81 s.

Check

A drive with 0.5 kg·m² of total inertia accelerates with 20 N·m of motor torque against 10 N·m of load to 3000 rpm.

(a)

How long does it take?

Write units the way you normally would: 1.5 s and 1500 ms are the same answer.

(b)

How much kinetic energy is then stored?

Check

A motor of 0.0001 kg·m² drives a 0.01 kg·m² load through a gearbox of ratio 15.

(a)

What total inertia does the motor see?

Write units the way you normally would: 1.5 kg·m² and 1500 g·m² are the same answer.

(b)

What ratio would accelerate the load fastest?

Check

A 100 kg table is moved by a ball screw with a lead of 5 mm per revolution, driven directly by a motor of 0.001 kg·m².

(a)

What inertia does the table present at the motor?

Write units the way you normally would: 1.5 kg·m² and 1500 g·m² are the same answer.

(b)

What is the ratio of load to motor inertia?

Check

A 75 kW fan, sized for full flow, runs 8000 hours a year at 0.5 of full speed under a variable-speed drive.

(a)

What power does it draw then (ideal affinity laws)?

Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.

(b)

How much energy does that save each year compared with full speed?

Check

Near an operating point, a motor's torque changes by −2 N·m per rad/s of speed and the load's by +0.1.

(a)

By how much does the net decelerating torque grow per rad/s of speed increase?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

Why is a fan load always stable on an induction motor's normal operating side, but a constant-power load can be unstable at low speed on a drive with a rising torque characteristic?

Check

A motor torque T drives a load through ratio n; motor inertia m, load inertia l.

Step 1

What is the motor's angular acceleration?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Check

Write run_up(torque, load, J, T, dt): integrate Jdω/dt = torque(ω) − load(ω) by RK4 from rest for T seconds, returning the speed list, and time_to(fraction, speeds, dt): the first time the speed reaches that fraction of its final value.

Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.

Explain why

Why does the best gear ratio for accelerating a load make the load's reflected inertia equal the motor's?

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.