S12 · Lesson 32 · Permanent-magnet DC and brushless DC motors
The permanent-magnet DC motor's straight speed–torque line, stall torque, peak power and peak efficiency, its torque and back-EMF constants, the mechanical time constant, and the brushless DC motor that replaces the commutator with Hall sensors and six-step switching
Replace a DC motor's field winding with permanent magnets and its equations get even simpler: the flux is fixed, so speed falls in a straight line with torque, from a no-load speed set by the supply to a stall torque set by the winding resistance. That's the motor in toys, car windows and disk drives. Move the magnets to the rotor and switch the windings electronically instead of with brushes, and it becomes the brushless DC motor of drones, fans and power tools, with the same straight line and none of the wear.
- A 24 V permanent-magnet DC motor ( = 0.05 in SI units, 0.4 A no-load current) against load torque: speed falls linearly, output power peaks at half the stall torque, and efficiency peaks at a much lighter load.
- Lowering the winding resistance raises the stall torque and the peak power; the no-load speed is fixed by the voltage.
- Motors meant for continuous duty run near the efficiency peak, far below the power peak.
Predict
A 24 V PM DC motor has 0.5 Ω of winding resistance. What's the most mechanical power it can deliver?
The motor is a source of 24 V behind 0.5 Ω, and the back-EMF is the "load" it delivers power into. Maximum power transfer comes when the back-EMF is half the supply, at half the no-load speed and half the stall torque: = 576/2 = 288 W. Efficiency there is only 50%, so this is a short-term rating.
Name it
Constants
For a PM motor the flux is fixed, so and , and in SI units (N·m/A) equals (V·s/rad). Hobby motors quote in rpm per volt: .
The speed–torque line
With winding resistance R and supply V:
from the no-load speed to the stall torque .
Power and efficiency
Output power peaks at with . Modeling friction as a constant no-load current , efficiency peaks at , with the stall current, where
The motor constant (torque per square root of copper loss) measures a design's quality independent of its winding.
Dynamics
With rotor inertia J, the speed responds to voltage with the mechanical time constant , usually much longer than the electrical one, .
Brushless DC
Magnets on the rotor, three-phase windings on the stator, and Hall sensors that tell an inverter which two phases to energize in each 60° of rotation (six-step commutation). With trapezoidal back-EMF, two phases in series carry the current: the motor behaves like a PM DC motor with twice the per-phase constant and twice the phase resistance. Torque ripples slightly at each commutation.
Worked example
Characterize the 24 V motor: R = 0.5 Ω, = 0.05, = 0.4 A, J = 2 × 10⁻⁵ kg·m².
Show the solution
- No-load speed. (4584 rpm, ignoring friction).
- Stall and peak power. The stall current is 48 A, the stall torque 2.4 N·m and the peak power 288 W.
- Peak efficiency. It comes at = 4.38 A:
- Mechanical time constant.
- Motor constant.
Answer a no-load speed of 480 rad/s (4584 rpm), a stall current of 48 A and stall torque of 2.4 N·m, 288 W peak power, 82.6% peak efficiency at 4.38 A, a 4.0 ms mechanical time constant, and = 0.0707 N·m/√W.
Worked example
A drone motor is rated 1000 rpm/V. What's its torque constant, and its torque at 20 A?
Show the solution
- Torque constant.
- Torque at 20 A.
- What suits which job. High- motors spin fast and make little torque per ampere, which suits propellers; a low- motor of the same size suits a direct-drive wheel.
Answer = 0.00955 N·m/A, so 20 A gives 0.191 N·m.
Worked example
A brushless DC motor driven by six-step commutation has a line-to-line back-EMF constant of 0.1 V·s/rad and 0.4 Ω line to line, on a 48 V bus. Find its no-load speed, stall torque and peak power, and its .
Show the solution
- Which constants apply. Two phases conduct in series, so the line-to-line constants apply.
- No-load speed. (4584 rpm).
- Stall current and torque.
- Peak power. at half the stall torque.
- Speed constant.
- In practice. The drive limits current far below 120 A, so the stall torque is a thermal and electronic limit, not an operating point.
Answer a no-load speed of 480 rad/s (4584 rpm), 12 N·m of stall torque, 1440 W peak power, and = 95.5 rpm/V.
Check
A PM DC motor with = 0.01 V·s/rad runs from 24 V. What's its ideal no-load speed?
Check
A PM DC motor ( = 0.01 N·m/A, R = 2 Ω) runs from 24 V. What's its stall torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
What's the most mechanical power a PM DC motor with R = 0.1 Ω can deliver from 24 V?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A PM DC motor on 12 V with R = 0.2 Ω has a no-load current of 0.5 A. What's its peak efficiency?
Check
A PM DC motor has J = 5 × 10⁻⁵ kg·m², R = 0.2 Ω and = 0.1. What's its mechanical time constant?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A brushless motor is rated 920 rpm/V. What torque does it make at 5 A?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A PM motor rated 200 rpm/V has 0.6 Ω of winding resistance and runs on 12 V.
(a)
What is its no-load speed (ignoring friction)?
(b)
What is its stall torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(c)
What is its peak mechanical power?
Check
A PM DC motor on V volts has resistance R, constant = k and rotor inertia J.
Step 1
What is its no-load speed (rad/s)?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is its stall torque?
Step 3
What is its mechanical time constant?
Explain why
Why is a PM DC motor's peak efficiency at a much lighter load than its peak power?
Two losses compete. Copper loss grows with the square of current, so it dominates at heavy load; at the peak-power point the back-EMF is half the supply and half the input power is burned in the winding. The other loss, friction and core loss, modeled as a constant no-load current, is a fixed cost that dominates at light load. Efficiency is best where the two are balanced, at the geometric mean of the no-load and stall currents, usually a tenth or less of the stall current. Motors are sized so that their continuous load sits near that point, and the peak-power capability is used only briefly.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.