S1232 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S12 · Lesson 32 · Permanent-magnet DC and brushless DC motors

The permanent-magnet DC motor's straight speed–torque line, stall torque, peak power and peak efficiency, its torque and back-EMF constants, the mechanical time constant, and the brushless DC motor that replaces the commutator with Hall sensors and six-step switching

Replace a DC motor's field winding with permanent magnets and its equations get even simpler: the flux is fixed, so speed falls in a straight line with torque, from a no-load speed set by the supply to a stall torque set by the winding resistance. That's the motor in toys, car windows and disk drives. Move the magnets to the rotor and switch the windings electronically instead of with brushes, and it becomes the brushless DC motor of drones, fans and power tools, with the same straight line and none of the wear.

  • A 24 V permanent-magnet DC motor (Kt=Ke = 0.05 in SI units, 0.4 A no-load current) against load torque: speed falls linearly, output power peaks at half the stall torque, and efficiency peaks at a much lighter load.
  • Lowering the winding resistance raises the stall torque and the peak power; the no-load speed is fixed by the voltage.
  • Motors meant for continuous duty run near the efficiency peak, far below the power peak.

Predict

A 24 V PM DC motor has 0.5 Ω of winding resistance. What's the most mechanical power it can deliver?

Name it

Constants

For a PM motor the flux is fixed, so T=KtI and E=Keω, and in SI units Kt (N·m/A) equals Ke (V·s/rad). Hobby motors quote Kv in rpm per volt: Kt=60/(2πKv).

The speed–torque line

With winding resistance R and supply V:

ω=VKe−RKtKeT

from the no-load speed ω0=V/Ke to the stall torque Ts=KtV/R.

Power and efficiency

Output power Tω peaks at Ts/2 with Pmax⁡=V2/4R. Modeling friction as a constant no-load current I0, efficiency peaks at I=I0Is, with Is=V/R the stall current, where

ηmax⁡=(1−I0/Is)2

The motor constant Km=Kt/R (torque per square root of copper loss) measures a design's quality independent of its winding.

Dynamics

With rotor inertia J, the speed responds to voltage with the mechanical time constant τm=JR/(KtKe), usually much longer than the electrical one, L/R.

Brushless DC

Magnets on the rotor, three-phase windings on the stator, and Hall sensors that tell an inverter which two phases to energize in each 60° of rotation (six-step commutation). With trapezoidal back-EMF, two phases in series carry the current: the motor behaves like a PM DC motor with twice the per-phase constant and twice the phase resistance. Torque ripples slightly at each commutation.

Worked example

Characterize the 24 V motor: R = 0.5 Ω, Kt=Ke = 0.05, I0 = 0.4 A, J = 2 × 10⁻⁵ kg·m².

Show the solution
  1. No-load speed. ω0=240.05=480rad/s (4584 rpm, ignoring friction).
  2. Stall and peak power. The stall current is 48 A, the stall torque 2.4 N·m and the peak power 288 W.
  3. Peak efficiency. It comes at 0.4×48 = 4.38 A: ηmax⁡=(1−0.4/48)2=82.6%
  4. Mechanical time constant. τm=2×10−5×0.50.052=4.0ms
  5. Motor constant. Km=0.050.5=0.0707N·m/√W

Answer a no-load speed of 480 rad/s (4584 rpm), a stall current of 48 A and stall torque of 2.4 N·m, 288 W peak power, 82.6% peak efficiency at 4.38 A, a 4.0 ms mechanical time constant, and Km = 0.0707 N·m/√W.

Worked example

A drone motor is rated 1000 rpm/V. What's its torque constant, and its torque at 20 A?

Show the solution
  1. Torque constant. Kt=602π×1000=0.00955N·m/A
  2. Torque at 20 A. T=20×0.00955=0.191N·m
  3. What suits which job. High-Kv motors spin fast and make little torque per ampere, which suits propellers; a low-Kv motor of the same size suits a direct-drive wheel.

Answer Kt = 0.00955 N·m/A, so 20 A gives 0.191 N·m.

Worked example

A brushless DC motor driven by six-step commutation has a line-to-line back-EMF constant of 0.1 V·s/rad and 0.4 Ω line to line, on a 48 V bus. Find its no-load speed, stall torque and peak power, and its Kv.

Show the solution
  1. Which constants apply. Two phases conduct in series, so the line-to-line constants apply.
  2. No-load speed. ω0=480.1=480rad/s (4584 rpm).
  3. Stall current and torque. Istall=480.4=120ATstall=0.1×120=12N·m
  4. Peak power. Pmax⁡=V24R=1440W at half the stall torque.
  5. Speed constant. Kv=602π×0.1=95.5rpm/V
  6. In practice. The drive limits current far below 120 A, so the stall torque is a thermal and electronic limit, not an operating point.

Answer a no-load speed of 480 rad/s (4584 rpm), 12 N·m of stall torque, 1440 W peak power, and Kv = 95.5 rpm/V.

Check

A PM DC motor with Ke = 0.01 V·s/rad runs from 24 V. What's its ideal no-load speed?

Check

A PM DC motor (Kt = 0.01 N·m/A, R = 2 Ω) runs from 24 V. What's its stall torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

What's the most mechanical power a PM DC motor with R = 0.1 Ω can deliver from 24 V?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

A PM DC motor on 12 V with R = 0.2 Ω has a no-load current of 0.5 A. What's its peak efficiency?

Check

A PM DC motor has J = 5 × 10⁻⁵ kg·m², R = 0.2 Ω and Kt=Ke = 0.1. What's its mechanical time constant?

Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.

Check

A brushless motor is rated 920 rpm/V. What torque does it make at 5 A?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

A PM motor rated 200 rpm/V has 0.6 Ω of winding resistance and runs on 12 V.

(a)

What is its no-load speed (ignoring friction)?

(b)

What is its stall torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

(c)

What is its peak mechanical power?

Check

A PM DC motor on V volts has resistance R, constant Kt=Ke = k and rotor inertia J.

Step 1

What is its no-load speed (rad/s)?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why is a PM DC motor's peak efficiency at a much lighter load than its peak power?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.