title: Permanent-magnet DC and brushless DC motors
heading: The permanent-magnet DC motor's straight speed–torque line, stall torque, peak power and peak efficiency, its torque and back-EMF constants, the mechanical time constant, and the brushless DC motor that replaces the commutator with Hall sensors and six-step switching
eyebrow: S12 · Lesson 32 · Permanent-magnet DC and brushless DC motors
xp: 50
---

::: hook
Replace a DC motor's field winding with permanent magnets and its equations get even simpler: the flux is fixed, so speed falls in a straight line with torque, from a no-load speed set by the supply to a stall torque set by the winding resistance. That's the motor in toys, car windows and disk drives. Move the magnets to the rotor and switch the windings electronically instead of with brushes, and it becomes the brushless DC motor of drones, fans and power tools, with the same straight line and none of the wear.
:::

::: play
- A 24 V permanent-magnet DC motor ($K_t = K_e$ = 0.05 in SI units, 0.4 A no-load current) against load torque: speed falls linearly, output power peaks at half the stall torque, and efficiency peaks at a much lighter load.
- Lowering the winding resistance raises the stall torque and the peak power; the no-load speed is fixed by the voltage.
- Motors meant for continuous duty run near the efficiency peak, far below the power peak.
:::

```sim plot
view: graph
x: T = 0..2.5 N·m
y: y = 0..300
slider: R = 0.2..2 step 0.05 = 0.5 Ω
slider: V = 6..36 step 1 = 24 V
plot: T*(V - (T/0.05 + 0.4)*R)/0.05 | samples: 400 | label: output power, W
plot: 100*T*(V - (T/0.05 + 0.4)*R)/0.05/(V*(T/0.05 + 0.4)) | samples: 400 | color: ch3 | label: efficiency, %
plot: (V - (T/0.05 + 0.4)*R)/0.05*60/(2*pi)/20 | samples: 400 | color: ch4 | dashed | label: speed ÷ 20, rpm
readout: stall torque, N·m = 0.05*V/R | digits: 3
readout: peak efficiency, % = 100*(1 - sqrt(0.4*R/V))^2 | digits: 3
```

::: predict
## A 24 V PM DC motor has 0.5 Ω of winding resistance. What's the most mechanical power it can deliver?

- [ ] 48 W
- [x] 288 W
- [ ] 576 W
- [ ] 1152 W

::: reveal
The motor is a source of 24 V behind 0.5 Ω, and the back-EMF is the "load" it delivers power into. Maximum power transfer comes when the back-EMF is half the supply, at half the no-load speed and half the stall torque: $V^2/4R$ = 576/2 = 288 W. Efficiency there is only 50%, so this is a short-term rating.
:::
:::

::: nameit
## Constants

For a PM motor the flux is fixed, so $T = K_tI$ and $E = K_e\omega$, and in SI units $K_t$ (N·m/A) equals $K_e$ (V·s/rad). Hobby motors quote $K_v$ in rpm per volt: $K_t = 60/(2\pi K_v)$.

## The speed–torque line

With winding resistance R and supply V:

$$\omega = \frac{V}{K_e} - \frac{R}{K_tK_e}T$$

from the no-load speed $\omega_0 = V/K_e$ to the stall torque $T_s = K_tV/R$.

## Power and efficiency

Output power $T\omega$ peaks at $T_s/2$ with $P_\max = V^2/4R$. Modeling friction as a constant no-load current $I_0$, efficiency peaks at $I = \sqrt{I_0I_s}$, with $I_s = V/R$ the stall current, where

$$\eta_\max = \left(1 - \sqrt{I_0/I_s}\right)^2$$

The **motor constant** $K_m = K_t/\sqrt{R}$ (torque per square root of copper loss) measures a design's quality independent of its winding.

## Dynamics

With rotor inertia J, the speed responds to voltage with the **mechanical time constant** $\tau_m = JR/(K_tK_e)$, usually much longer than the electrical one, $L/R$.

## Brushless DC

Magnets on the rotor, three-phase windings on the stator, and Hall sensors that tell an inverter which two phases to energize in each 60° of rotation (**six-step commutation**). With trapezoidal back-EMF, two phases in series carry the current: the motor behaves like a PM DC motor with twice the per-phase constant and twice the phase resistance. Torque ripples slightly at each commutation.
:::

::: example
## Characterize the 24 V motor: R = 0.5 Ω, $K_t = K_e$ = 0.05, $I_0$ = 0.4 A, J = 2 × 10⁻⁵ kg·m².

::: solution
1. **No-load speed.**
   $$\begin{aligned} \omega_0 &= \frac{24}{0.05} \\ &= 480\ \text{rad/s} \end{aligned}$$
   (4584 rpm, ignoring friction).
2. **Stall and peak power.** The stall current is 48 A, the stall torque 2.4 N·m and the peak power 288 W.
3. **Peak efficiency.** It comes at $\sqrt{0.4 \times 48}$ = 4.38 A:
   $$\begin{aligned} \eta_\max &= \left(1 - \sqrt{0.4/48}\right)^2 \\ &= 82.6\% \end{aligned}$$
4. **Mechanical time constant.**
   $$\begin{aligned} \tau_m &= \frac{2 \times 10^{-5} \times 0.5}{0.05^2} \\ &= 4.0\ \text{ms} \end{aligned}$$
5. **Motor constant.**
   $$\begin{aligned} K_m &= \frac{0.05}{\sqrt{0.5}} \\ &= 0.0707\ \text{N·m/√W} \end{aligned}$$

**Answer:** a no-load speed of 480 rad/s (4584 rpm), a stall current of 48 A and stall torque of 2.4 N·m, 288 W peak power, 82.6% peak efficiency at 4.38 A, a 4.0 ms mechanical time constant, and $K_m$ = 0.0707 N·m/√W.
:::
:::

::: example
## A drone motor is rated 1000 rpm/V. What's its torque constant, and its torque at 20 A?

::: solution
1. **Torque constant.**
   $$\begin{aligned} K_t &= \frac{60}{2\pi \times 1000} \\ &= 0.00955\ \text{N·m/A} \end{aligned}$$
2. **Torque at 20 A.**
   $$\begin{aligned} T &= 20 \times 0.00955 \\ &= 0.191\ \text{N·m} \end{aligned}$$
3. **What suits which job.** High-$K_v$ motors spin fast and make little torque per ampere, which suits propellers; a low-$K_v$ motor of the same size suits a direct-drive wheel.

**Answer:** $K_t$ = 0.00955 N·m/A, so 20 A gives 0.191 N·m.
:::
:::

::: example
## A brushless DC motor driven by six-step commutation has a line-to-line back-EMF constant of 0.1 V·s/rad and 0.4 Ω line to line, on a 48 V bus. Find its no-load speed, stall torque and peak power, and its $K_v$.

::: solution
1. **Which constants apply.** Two phases conduct in series, so the line-to-line constants apply.
2. **No-load speed.**
   $$\begin{aligned} \omega_0 &= \frac{48}{0.1} \\ &= 480\ \text{rad/s} \end{aligned}$$
   (4584 rpm).
3. **Stall current and torque.**
   $$\begin{aligned} I_\text{stall} &= \frac{48}{0.4} \\ &= 120\ \text{A} \\ T_\text{stall} &= 0.1 \times 120 \\ &= 12\ \text{N·m} \end{aligned}$$
4. **Peak power.**
   $$\begin{aligned} P_\max &= \frac{V^2}{4R} \\ &= 1440\ \text{W} \end{aligned}$$
   at half the stall torque.
5. **Speed constant.**
   $$\begin{aligned} K_v &= \frac{60}{2\pi \times 0.1} \\ &= 95.5\ \text{rpm/V} \end{aligned}$$
6. **In practice.** The drive limits current far below 120 A, so the stall torque is a thermal and electronic limit, not an operating point.

**Answer:** a no-load speed of 480 rad/s (4584 rpm), 12 N·m of stall torque, 1440 W peak power, and $K_v$ = 95.5 rpm/V.
:::
:::

::: check
given: V = 12 | 24 | 48; K = 0.01 | 0.05 | 0.2
answer: V/K*60/(2*pi)
unit: rpm
tolerance: 0.5%

## A PM DC motor with $K_e$ = {K} V·s/rad runs from {V} V. What's its ideal no-load speed?

::: right
Right. $V/K_e$ = {answer} rpm.
:::

::: misses
- [V/K] That's in rad/s; convert to rpm.
- [any] Not yet. Back-EMF equals the supply.
:::
:::

::: check
given: V = 12 | 24 | 48; K = 0.01 | 0.05 | 0.2; R = 0.1 | 0.5 | 2
answer: K*V/R
unit: N·m
tolerance: 0.5%

## A PM DC motor ($K_t$ = {K} N·m/A, R = {R} Ω) runs from {V} V. What's its stall torque?

::: right
Right. $K_tV/R$ = {answer} N·m.
:::

::: misses
- [any] Not yet. Stall current times the torque constant.
:::
:::

::: check
given: V = 12 | 24 | 48; R = 0.1 | 0.5 | 2
answer: V^2/(4*R)
unit: W
tolerance: 0.5%

## What's the most mechanical power a PM DC motor with R = {R} Ω can deliver from {V} V?

::: right
Right. $V^2/4R$ = {answer} W, at half the stall torque.
:::

::: misses
- [V^2/R] That's the stall input; maximum output comes at half voltage across R.
- [any] Not yet. Maximum power transfer.
:::
:::

::: check
given: V = 12 | 24; R = 0.2 | 1; I = 0.1 | 0.5
answer: 100*(1 - sqrt(I*R/V))^2
unit: %
tolerance: 0.5%

## A PM DC motor on {V} V with R = {R} Ω has a no-load current of {I} A. What's its peak efficiency?

::: right
Right. $(1 - \sqrt{I_0/I_s})^2$ = {answer}%.
:::

::: misses
- [any] Not yet. The stall current is V/R.
:::
:::

::: check
given: J = 1 | 5 | 50; R = 0.2 | 1 | 4; K = 0.02 | 0.1
answer: J*1e-5*R/K^2*1000
unit: ms
tolerance: 0.5%

## A PM DC motor has J = {J} × 10⁻⁵ kg·m², R = {R} Ω and $K_t = K_e$ = {K}. What's its mechanical time constant?

::: right
Right. $JR/(K_tK_e)$ = {answer} ms.
:::

::: misses
- [J*1e-5*R/K*1000] Both constants appear: $K_t$ converts current to torque and $K_e$ speed to voltage.
- [any] Not yet. $\tau_m = JR/K^2$.
:::
:::

::: check
given: k = 100 | 920 | 2300; I = 5 | 30
answer: 60/(2*pi*k)*I
unit: N·m
tolerance: 0.5%

## A brushless motor is rated {k} rpm/V. What torque does it make at {I} A?

::: right
Right. $K_t = 60/(2\pi K_v)$, so {answer} N·m.
:::

::: misses
- [I/k] Convert rpm per volt to rad/s per volt first.
- [any] Not yet. $K_t$ in SI is $1/K_v$ with $K_v$ in rad/s per volt.
:::
:::

::: check
kind: parts
given: K = 50 | 200 | 900; V = 12 | 24 | 48; R = 0.05 | 0.2 | 0.6

## A PM motor rated {K} rpm/V has {R} Ω of winding resistance and runs on {V} V.

::: part
answer: K*V
unit: rpm
tolerance: 0.5%

### What is its no-load speed (ignoring friction)?

::: misses
- [any] $K_vV$.
:::
:::

::: part
answer: 60/(2*pi*K)*V/R
unit: N·m
tolerance: 0.5%

### What is its stall torque?

::: misses
- [any] $K_t = 60/(2\pi K_v)$, times $V/R$.
:::
:::

::: part
answer: V^2/(4*R)
unit: W
tolerance: 0.5%

### What is its peak mechanical power?

::: misses
- [V^2/R] That's the stall input power; output peaks at half the stall torque.
- [any] $V^2/4R$.
:::
:::
:::

::: check
kind: derivation
vars: V = 3..600, R = 0.01..10, k = 0.001..2, J = 0.000001..0.1

## A PM DC motor on V volts has resistance R, constant $K_t = K_e$ = k and rotor inertia J.

::: step
answer: V/k

### What is its no-load speed (rad/s)?
:::

::: step
answer: k*V/R

### What is its stall torque?
:::

::: step
answer: J*R/k^2

### What is its mechanical time constant?
:::

::: right
Right. A larger constant lowers the speed, raises the torque and quickens the response.
:::
:::

::: explain
## Why is a PM DC motor's peak efficiency at a much lighter load than its peak power?

::: model
Two losses compete. Copper loss grows with the square of current, so it dominates at heavy load; at the peak-power point the back-EMF is half the supply and half the input power is burned in the winding. The other loss, friction and core loss, modeled as a constant no-load current, is a fixed cost that dominates at light load. Efficiency is best where the two are balanced, at the geometric mean of the no-load and stall currents, usually a tenth or less of the stall current. Motors are sized so that their continuous load sits near that point, and the peak-power capability is used only briefly.
:::
:::

::: practice

::: check
given: V = 6 | 48; R = 0.05 | 3
answer: V^2/(4*R)
unit: W
tolerance: 0.5%

## Peak power: {V} V, {R} Ω?

::: misses
- [any] $V^2/4R$.
:::
:::

::: check
given: V = 9 | 36; K = 0.005 | 0.3; R = 0.08 | 2.5
answer: K*V/R
unit: N·m
tolerance: 0.5%

## Stall torque: {V} V, K = {K}, R = {R} Ω?

::: misses
- [any] $KV/R$.
:::
:::

::: check
given: V = 12 | 48; R = 0.1 | 2; I = 0.05 | 0.8
answer: 100*(1 - sqrt(I*R/V))^2
unit: %
tolerance: 0.5%

## Peak efficiency: {V} V, {R} Ω, $I_0$ = {I} A?

::: misses
- [any] $(1 - \sqrt{I_0R/V})^2$.
:::
:::
:::