S1242 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S12 · Lesson 42 · Permanent-magnet synchronous motor control

Surface and interior permanent-magnet machines in the rotor's dq frame, magnet and reluctance torque, the maximum torque per ampere, the voltage limit that sets base speed, field weakening with negative d-axis current, and the characteristic current that decides how fast the motor can go

The traction motor of nearly every electric car is an interior permanent-magnet synchronous machine: magnets buried in the rotor iron, a three-phase stator, and an inverter that controls its dq currents with field orientation that is far simpler than an induction motor's, since the rotor's position is the flux's position. Two questions shape its control. At a given current, which split between d and q gives the most torque? And at high speed, where the back-EMF reaches the battery's voltage, how can negative d-axis current weaken the magnets' field enough to keep going?

  • An interior PM motor's torque at fixed current magnitude Is against the current angle β, measured from the q axis toward negative d: id=−Issin⁡β, iq=Iscos⁡β.
  • With Lq=Ld (a surface magnet machine) the best angle is 0: all current on q. With Lq>Ld, some negative d current adds reluctance torque, and the peak moves to a positive angle.
  • The readout gives the maximum-torque-per-ampere angle from the closed form.

Predict

A surface PM motor (Ld=Lq) is below base speed. What d-axis current gives the most torque per ampere?

Name it

Torque

In the rotor frame, with λd=Ldid+λm and λq=Lqiq:

T=32P2[λmiq+(Ld−Lq)idiq]

The first term is magnet torque; the second, reluctance torque, is positive for negative id when Lq>Ld (interior magnets).

Maximum torque per ampere

At current magnitude Is, torque is greatest at

id=λm−λm2+8(Lq−Ld)2Is24(Lq−Ld),iq=Is2−id2

The voltage limit

Neglecting resistance, the steady phase voltage's peak is ω(Lqiq)2+(Ldid+λm)2, at electrical speed ω. The inverter caps it at Vmax⁡. With id = 0 this sets the base speed, ωb=Vmax⁡/(Lqiq)2+λm2.

Field weakening

Above base speed, negative id reduces Ldid+λm, the d-axis flux, keeping the voltage within the limit at the cost of current that could have made torque. The characteristic current λm/Ld is the d current that cancels the magnet flux entirely. If it's within the drive's current rating, the motor can in principle run at any speed; if not, at full current the speed is limited to

ωmax⁡=Vmax⁡λm−LdImax⁡

Worked example

An 8-pole interior PM motor: λm = 0.08 Wb, Ld = 0.2 mH, Lq = 0.5 mH, at 200 A. Find the MTPA currents and torque.

Show the solution
  1. Inside the square root. With Lq−Ld = 0.3 mH, 0.0064+8×(0.3mH)2×2002=0.0352
  2. MTPA d-axis current. id=0.08−0.03524×0.3mH=−89.7A and iq = 178.8 A (β = 26.6°).
  3. Torque. T=1.5×4×(0.08×178.8+0.3mH×89.7×178.8)=114.7N·m
  4. Compare with id = 0. With all 200 A on q the torque is 96 N·m: reluctance adds 19%.

Answer id = −89.7 A and iq = 178.8 A (β = 26.6°), for 114.7 N·m.

Worked example

An 8-pole surface PM motor: λm = 0.1 Wb, L = 0.5 mH, 100 A, 150 V peak phase. Find its base speed and its top speed.

Show the solution
  1. Base speed. With iq = 100 A, ωb=1500.052+0.12=1342rad/s electrical, 335 rad/s mechanical: 3203 rpm, at 60 N·m.
  2. Characteristic current. It's 0.1/0.0005 = 200 A, more than the 100 A rating, so even with all 100 A on −d the flux only halves.
  3. Top speed. ωmax⁡=1500.1−0.05=3000rad/s electrical, 7162 rpm, with no torque left.

Answer a base speed of 3203 rpm (1342 rad/s electrical) at 60 N·m, and a top speed of 7162 rpm (3000 rad/s electrical).

Worked example

Run the 8-pole interior PM motor at 100 A instead of 200 A. How much does MTPA gain over id = 0 now?

Show the solution
  1. Inside the square root. At 100 A, 0.0064+8×(0.3mH)2×1002=0.0136
  2. MTPA currents. id=0.08−0.01364×0.3mH=−30.5A and iq = 95.2 A, a current angle of 17.8° instead of 26.6°.
  3. Torque. T=1.5×4×(0.08×95.2+0.3mH×30.5×95.2)=50.9N·m
  4. Compare with id = 0. That's against 48.0 N·m with id = 0: a 6% gain, against 19% at 200 A.
  5. Why the gain shrinks. Reluctance torque grows with the square of current, so MTPA matters most near peak torque.

Answer MTPA gives 50.9 N·m against 48.0 N·m with id = 0, a gain of only 6% (19% at 200 A).

Check

An 8-pole surface PM motor with λm = 0.03 Wb carries iq = 300 A, id = 0. What torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

An interior PM motor (6 poles, λm = 0.05 Wb, Ld = 0.3 mH, Lq = 0.9 mH) carries id = −40 A and iq = 80 A. What torque?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

For an interior PM motor with λm = 0.05 Wb, Ld = 0.15 mH and Lq = 0.9 mH, what d-axis current gives maximum torque at 250 A?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A 4-pole surface PM motor (λm = 0.05 Wb, L = 1 mH) carries iq = 150 A with 200 V peak phase available. What's its base speed?

Check

What's the characteristic current of a PM motor with λm = 0.1 Wb and Ld = 0.2 mH?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A 4-pole surface PM motor (λm = 0.08 Wb, L = 0.6 mH) has 120 A and 100 V peak phase available. With all its current on −d, what's its top speed?

Check

A 4-pole surface PM motor has λm = 0.05 Wb and L = 0.3 mH, rated 100 A, on an inverter limited to 300 V peak per phase.

(a)

What is its base speed at rated current?

(b)

What is its characteristic current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

An interior PM motor (λm = m, Ld = x, Lq = x + y) carries current magnitude I under MTPA.

Step 1

What is id?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does an interior permanent-magnet motor use negative d-axis current even below base speed?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.