S12 · Lesson 42 · Permanent-magnet synchronous motor control
Surface and interior permanent-magnet machines in the rotor's dq frame, magnet and reluctance torque, the maximum torque per ampere, the voltage limit that sets base speed, field weakening with negative d-axis current, and the characteristic current that decides how fast the motor can go
The traction motor of nearly every electric car is an interior permanent-magnet synchronous machine: magnets buried in the rotor iron, a three-phase stator, and an inverter that controls its dq currents with field orientation that is far simpler than an induction motor's, since the rotor's position is the flux's position. Two questions shape its control. At a given current, which split between d and q gives the most torque? And at high speed, where the back-EMF reaches the battery's voltage, how can negative d-axis current weaken the magnets' field enough to keep going?
- An interior PM motor's torque at fixed current magnitude against the current angle β, measured from the q axis toward negative d: , .
- With (a surface magnet machine) the best angle is 0: all current on q. With , some negative d current adds reluctance torque, and the peak moves to a positive angle.
- The readout gives the maximum-torque-per-ampere angle from the closed form.
Predict
A surface PM motor () is below base speed. What d-axis current gives the most torque per ampere?
With the reluctance term vanishes, so torque is and any d current only adds copper loss. Interior machines, with , are the ones that benefit from negative .
Name it
Torque
In the rotor frame, with and :
The first term is magnet torque; the second, reluctance torque, is positive for negative when (interior magnets).
Maximum torque per ampere
At current magnitude , torque is greatest at
The voltage limit
Neglecting resistance, the steady phase voltage's peak is , at electrical speed ω. The inverter caps it at . With = 0 this sets the base speed, .
Field weakening
Above base speed, negative reduces , the d-axis flux, keeping the voltage within the limit at the cost of current that could have made torque. The characteristic current is the d current that cancels the magnet flux entirely. If it's within the drive's current rating, the motor can in principle run at any speed; if not, at full current the speed is limited to
Worked example
An 8-pole interior PM motor: = 0.08 Wb, = 0.2 mH, = 0.5 mH, at 200 A. Find the MTPA currents and torque.
Show the solution
- Inside the square root. With = 0.3 mH,
- MTPA d-axis current. and = 178.8 A (β = 26.6°).
- Torque.
- Compare with = 0. With all 200 A on q the torque is 96 N·m: reluctance adds 19%.
Answer = −89.7 A and = 178.8 A (β = 26.6°), for 114.7 N·m.
Worked example
An 8-pole surface PM motor: = 0.1 Wb, L = 0.5 mH, 100 A, 150 V peak phase. Find its base speed and its top speed.
Show the solution
- Base speed. With = 100 A, electrical, 335 rad/s mechanical: 3203 rpm, at 60 N·m.
- Characteristic current. It's 0.1/0.0005 = 200 A, more than the 100 A rating, so even with all 100 A on −d the flux only halves.
- Top speed. electrical, 7162 rpm, with no torque left.
Answer a base speed of 3203 rpm (1342 rad/s electrical) at 60 N·m, and a top speed of 7162 rpm (3000 rad/s electrical).
Worked example
Run the 8-pole interior PM motor at 100 A instead of 200 A. How much does MTPA gain over = 0 now?
Show the solution
- Inside the square root. At 100 A,
- MTPA currents. and = 95.2 A, a current angle of 17.8° instead of 26.6°.
- Torque.
- Compare with = 0. That's against 48.0 N·m with = 0: a 6% gain, against 19% at 200 A.
- Why the gain shrinks. Reluctance torque grows with the square of current, so MTPA matters most near peak torque.
Answer MTPA gives 50.9 N·m against 48.0 N·m with = 0, a gain of only 6% (19% at 200 A).
Check
An 8-pole surface PM motor with = 0.03 Wb carries = 300 A, = 0. What torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
An interior PM motor (6 poles, = 0.05 Wb, = 0.3 mH, = 0.9 mH) carries = −40 A and = 80 A. What torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
For an interior PM motor with = 0.05 Wb, = 0.15 mH and = 0.9 mH, what d-axis current gives maximum torque at 250 A?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A 4-pole surface PM motor ( = 0.05 Wb, L = 1 mH) carries = 150 A with 200 V peak phase available. What's its base speed?
Check
What's the characteristic current of a PM motor with = 0.1 Wb and = 0.2 mH?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A 4-pole surface PM motor ( = 0.08 Wb, L = 0.6 mH) has 120 A and 100 V peak phase available. With all its current on −d, what's its top speed?
Check
A 4-pole surface PM motor has = 0.05 Wb and L = 0.3 mH, rated 100 A, on an inverter limited to 300 V peak per phase.
(a)
What is its base speed at rated current?
(b)
What is its characteristic current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
An interior PM motor ( = m, = x, = x + y) carries current magnitude I under MTPA.
Step 1
What is ?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is ?
Explain why
Why does an interior permanent-magnet motor use negative d-axis current even below base speed?
Burying the magnets inside the rotor iron leaves iron paths along the q axis and puts the low-permeability magnets in the d-axis path, so is larger than . The torque then has a reluctance term, , which is positive when is negative. Splitting a given current between a negative d component and a q component therefore yields more torque than putting it all on q: the q current's magnet torque falls a little, but the reluctance torque more than makes up for it. Maximum torque per ampere control picks the best split at each current, which lowers copper loss for a given torque and lets the same inverter rating produce more torque. At high speed the same negative d current doubles as field weakening.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.