title: "Problem set 10: electric machines across the course"
heading: "Problem set 10: problems that combine magnetics, transformers, windings, synchronous and induction machines, DC and PM motors, dq models, drives and ratings"
eyebrow: S12 · Problem set 10
type: problems
---

::: hook
These problems draw on the whole course, and most chain several ideas: a winding's turns turned into a voltage, test data turned into an equivalent circuit and a torque, a drive's frequency turned into a speed and a slip, a duty cycle turned into a thermal rating. Work them as a review before the final.
:::

::: pool
pick: 12

::: check
kind: parts
given: P = 4 | 6; f = 50 | 60; N = 36 | 72; q = 2 | 3; r = 0.833 | 0.889; B = 0.8 | 1; l = 0.2 | 0.4; R = 0.1 | 0.2

## A {P}-pole, {f} Hz machine: {N} series turns per phase, q = {q}, pitch {r}, gap field {B} T peak, rotor radius {R} m, length {l} m.

::: part
answer: sin(r*pi/2)*sin(pi/6)/(q*sin(pi/(6*q)))
tolerance: 0.5%

### Winding factor?

::: misses
- [any] $k_pk_d$.
:::
:::

::: part
answer: sqrt(2)*pi*f*sin(r*pi/2)*sin(pi/6)/(q*sin(pi/(6*q)))*N*4/P*B*l*R
unit: V
tolerance: 0.5%

### Phase EMF?

::: misses
- [any] $4.44fk_wN\Phi_p$ with $\Phi_p = \frac{4}{P}BlR$.
:::
:::

::: part
answer: 120*f/P
unit: rpm
tolerance: 0.5%

### Speed?

::: misses
- [any] $120f/P$.
:::
:::
:::

::: check
kind: parts
given: S = 50 | 500; c = 0.2 | 0.4; u = 0.8 | 1.5; x = 0.5 | 0.9; r = 0.008 | 0.015; X = 0.04 | 0.08; p = 0.8 | 0.9

## A {S} kVA transformer: core {c}%, full-load copper {u}%, series impedance {r} + j{X} pu, at {x} load, pf {p} lagging.

::: part
answer: 100*x*S*p/(x*S*p + c*S/100 + x^2*u*S/100)
unit: %
tolerance: 0.5%

### Efficiency?

::: misses
- [any] $xSp/(xSp + P_c + x^2P_{cu})$.
:::
:::

::: part
answer: 100*x*(r*p + X*sqrt(1 - p^2))
unit: %
tolerance: 0.5%

### Approximate regulation at this load?

::: misses
- [any] Scale the full-load drop by x.
:::
:::
:::

::: check
kind: parts
given: V = 13.8 | 22; S = 100 | 600; x = 1 | 1.6; i = 0.7 | 1; p = 0.85 | 0.95

## A {S} MVA, {V} kV round-rotor generator with $X_s$ = {x} pu delivers {i} pu at power factor {p} lagging.

::: part
answer: sqrt((1 + x*i*sqrt(1 - p^2))^2 + (x*i*p)^2)*V*1000/sqrt(3)
unit: V
tolerance: 0.5%

### Excitation voltage per phase?

::: misses
- [any] $|V + jX_sI|$ times the phase base voltage.
:::
:::

::: part
answer: sqrt((1 + x*i*sqrt(1 - p^2))^2 + (x*i*p)^2)/x*S
unit: MW
tolerance: 0.5%

### Pull-out power at this excitation?

::: misses
- [any] $E_f/X_s \times S$.
:::
:::
:::

::: check
kind: parts
given: v = 10 | 20; d = 25 | 40; I = 9 | 15; t = 400 | 900; V = 460 | 400; b = 30 | 50; P = 1200 | 2400; f = 15 | 20; let q = sqrt(3)*b*sqrt((P/(3*b^2))^2 + (0.9*f/60)^2)

## Motor tests: DC {v} V at {d} A; no load {V} V, {I} A, rotational loss {t} W; blocked rotor at {f} Hz: {q} V, {b} A, {P} W (class A).

::: part
answer: P/(3*b^2) - v/(2*d)
unit: Ω
tolerance: 0.5%

### $R_2$?

::: misses
- [any] $P/(3I^2) - R_1$.
:::
:::

::: part
answer: 0.5*sqrt((q/sqrt(3)/b)^2 - (P/(3*b^2))^2)*60/f
unit: Ω
tolerance: 0.5%

### $X_1$?

::: misses
- [any] Half of $X_1 + X_2$ at 60 Hz.
:::
:::

::: part
answer: V/sqrt(3)/I - 0.5*sqrt((q/sqrt(3)/b)^2 - (P/(3*b^2))^2)*60/f
unit: Ω
tolerance: 0.5%

### $X_m$?

::: misses
- [any] $X_\text{nl} - X_1$.
:::
:::
:::

::: check
kind: parts
given: V = 150 | 260; R = 0.15 | 0.3; X = 0.9 | 1.6; r = 0.12 | 0.25; P = 4 | 6

## Thévenin {V} V, $R_\text{th}$ = {R}, $X_\text{th} + X_2$ = {X}, $R_2$ = {r} Ω; {P} poles on 60 Hz.

::: part
answer: r/sqrt(R^2 + X^2)
tolerance: 0.5%

### Slip at breakdown?

::: misses
- [any] $R_2/|Z|$.
:::
:::

::: part
answer: 120*60/P*(1 - r/sqrt(R^2 + X^2))
unit: rpm
tolerance: 0.5%

### Speed at breakdown?

::: misses
- [any] $(1 - s)n_s$.
:::
:::

::: part
answer: 1.5*V^2/(4*pi*60/P*(R + sqrt(R^2 + X^2)))
unit: N·m
tolerance: 0.5%

### Breakdown torque?

::: misses
- [any] $1.5V^2/(\omega_s(R + |Z|))$.
:::
:::
:::

::: check
kind: parts
given: V = 400 | 460; b = 50 | 60; P = 4 | 6; f = 20 | 40 | 90; d = 25 | 45; T = 100 | 300

## A {V} V, {b} Hz, {P}-pole motor rated {T} N·m on a drive at {f} Hz (constant V/f below base, constant voltage above), needing {d} rpm of slip speed.

::: part
answer: 120*f/P - d
unit: rpm
tolerance: 0.5%

### Speed?

::: misses
- [any] $n_s - \Delta n$.
:::
:::

::: part
answer: V*(f/b + 1 - abs(f/b - 1))/2
unit: V
tolerance: 0.5%

### Drive voltage?

::: misses
- [any] $Vf/f_b$, capped at V.
:::
:::

::: part
answer: T*(f/b + 1 - abs(f/b - 1))/2*b/f
unit: N·m
tolerance: 0.5%

### Torque available at rated current?

::: misses
- [any] Rated below base; $Tf_b/f$ above.
:::
:::
:::

::: check
kind: parts
given: V = 240 | 500; K = 1.5 | 3; R = 0.1 | 0.3; T = 60 | 200; k = 0.75 | 0.9

## A separately excited DC motor ({V} V, $K_a\Phi$ = {K}, $R_a$ = {R} Ω) with field at {k} of rated, carrying {T} N·m.

::: part
answer: T/(k*K)
unit: A
tolerance: 0.5%

### Armature current?

::: misses
- [any] $T/(kK\Phi)$.
:::
:::

::: part
answer: (V - T/(k*K)*R)/(k*K)*60/(2*pi)
unit: rpm
tolerance: 0.5%

### Speed?

::: misses
- [any] $(V - IR)/(kK\Phi)$.
:::
:::
:::

::: check
kind: parts
given: V = 24 | 48; R = 0.1 | 0.4; K = 0.04 | 0.1; I = 0.3 | 0.8; J = 3 | 15

## A PM DC motor: {V} V, R = {R} Ω, K = {K}, no-load current {I} A, J = {J} × 10⁻⁵ kg·m².

::: part
answer: K*V/R
unit: N·m
tolerance: 0.5%

### Stall torque?

::: misses
- [any] $KV/R$.
:::
:::

::: part
answer: 100*(1 - sqrt(I*R/V))^2
unit: %
tolerance: 0.5%

### Peak efficiency?

::: misses
- [any] $(1 - \sqrt{I_0/I_s})^2$.
:::
:::

::: part
answer: J*1e-5*R/K^2*1000
unit: ms
tolerance: 0.5%

### Mechanical time constant?

::: misses
- [any] $JR/K^2$.
:::
:::
:::

::: check
kind: parts
given: P = 6 | 8; l = 0.06 | 0.1; a = 0.15 | 0.25; b = 0.5 | 0.8; I = 120 | 250; V = 150 | 300; w = 1000 | 2000

## An interior PM motor: {P} poles, $\lambda_m$ = {l} Wb, $L_d$ = {a} mH, $L_q$ = {b} mH, {I} A; {V} V peak phase available.

::: part
answer: (l - sqrt(l^2 + 8*((b - a)*1e-3)^2*I^2))/(4*(b - a)*1e-3)
unit: A
tolerance: 0.5%

### MTPA $i_d$?

::: misses
- [any] The MTPA formula.
:::
:::

::: part
answer: l/(a*1e-3)
unit: A
tolerance: 0.5%

### Characteristic current?

::: misses
- [any] $\lambda_m/L_d$.
:::
:::

::: part
answer: w*l
unit: V
tolerance: 0.5%

### Back-EMF peak at {w} electrical rad/s, no current?

::: misses
- [any] $\omega\lambda_m$.
:::
:::
:::

::: check
kind: parts
given: l = 0.12 | 0.18; a = 1.4 | 2; f = 0.15 | 0.25; k = 0.04 | 0.08; t = 0.05 | 0.12; T = 0.8 | 1.5

## A generator: $X_l$ = {l}, $X_{ad}$ = {a}, $X_{fl}$ = {f}, $X_{kdl}$ = {k} pu, $T''_d$ = 0.03 s, $T'_d$ = {T} s, shorted from 1 pu.

::: part
answer: 1/(l + 1/(1/a + 1/f + 1/k))
tolerance: 0.5%

### Initial symmetrical current?

::: misses
- [any] $1/X''_d$.
:::
:::

::: part
answer: 1/(l + a) + (1/(l + a*f/(a + f)) - 1/(l + a))*exp(-t/T) + (1/(l + 1/(1/a + 1/f + 1/k)) - 1/(l + a*f/(a + f)))*exp(-t/0.03)
tolerance: 0.5%

### AC current at {t} s?

::: misses
- [any] Three levels, two decays.
:::
:::
:::

::: check
kind: parts
given: M = 50 | 100; k = 1.03 | 1.06; R = 0.15 | 0.35; l = 0.5 | 0.9; q = 25 | 70; P = 4 | 6

## Field-oriented control: $L_m$ = {M} mH, $L_r$ = {k} $L_m$, $R_r$ = {R} Ω, {P} poles, {l} Wb, $i_{qs}$ = {q} A.

::: part
answer: l/(M*1e-3)
unit: A
tolerance: 0.5%

### $i_{ds}$?

::: misses
- [any] $\lambda_r/L_m$.
:::
:::

::: part
answer: 1.5*P/2/k*l*q
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] $\frac{3}{2}\frac{P}{2}\frac{L_m}{L_r}\lambda_ri_{qs}$.
:::
:::

::: part
answer: M*1e-3*q/(k*M*1e-3/R*l)
unit: rad/s
tolerance: 0.5%

### Slip?

::: misses
- [any] $L_mi_{qs}/(\tau_r\lambda_r)$.
:::
:::
:::

::: check
kind: parts
given: a = 100 | 300; t = 3 | 8; b = 20 | 60; u = 15 | 40; r = 1.25 | 1.4

## A duty cycle of {a} N·m for {t} s and {b} N·m for {u} s; a winding whose resistance has risen to {r} times its 25 °C value.

::: part
answer: sqrt((a^2*t + b^2*u)/(t + u))
unit: N·m
tolerance: 0.5%

### RMS torque?

::: misses
- [any] $\sqrt{\sum T^2t/\sum t}$.
:::
:::

::: part
answer: r*(234.5 + 25) - 234.5
unit: °C
tolerance: 0.5%

### Winding temperature?

::: misses
- [any] $r(234.5 + 25) - 234.5$.
:::
:::
:::

::: check
kind: parts
given: P = 5 | 45 | 300; n = 1000 | 1500 | 3000; s = 20 | 35; r = 0.8 | 1.5

## A {P} kW, {n} rpm machine is sized at {s} kPa with a length-to-diameter ratio of {r}.

::: part
answer: (2*P*1e3/(n*2*pi/60)/(pi*s*1e3*r))^(1/3)
unit: m
tolerance: 0.5%

### What rotor diameter does it need?

::: misses
- [any] $T = \frac\pi2\sigma D^3(l/D)$.
:::
:::
:::

::: check
kind: parts
given: H = 2.5 | 5; E = 1.3 | 1.7; X = 1 | 1.4; e = 0.15 | 0.4; d = 25 | 45; f = 50 | 60

## A {f} Hz generator (H = {H} s, $E_f$ = {E}, $X_s$ = {X} pu, {e} pu to the bus) runs at a {d}° load angle.

::: part
answer: E/(X + e)*cos(d*pi/180)
tolerance: 0.5%

### What is its synchronizing power coefficient (pu per radian)?

::: misses
- [any] $\frac{E_fV}{X_s + X_e}\cos\delta$.
:::
:::

::: part
answer: sqrt(2*pi*f*E/(X + e)*cos(d*pi/180)/(2*H))/(2*pi)
unit: Hz
tolerance: 0.5%

### At what frequency does it swing?

::: misses
- [any] $\sqrt{\omega_sP_s/2H}/2\pi$.
:::
:::
:::

::: check
kind: parts
given: m = 300 | 1500; g = 6 | 15; i = 10 | 25

## A suspension magnet holds {m} kg at a {g} mm gap with {i} A.

::: part
answer: 2*m*9.81/(g*1e-3)/1e6
unit: MN/m
tolerance: 0.5%

### What is its negative stiffness?

::: misses
- [any] $2F/g$.
:::
:::

::: part
answer: 2*m*9.81/(g*1e-3)/(2*m*9.81/i)
unit: A/m
tolerance: 0.5%

### What proportional gain just cancels it?

::: misses
- [any] $k_g/k_i$.
:::
:::
:::
:::