title: "Problem set 11: designing with machines"
heading: "Problem set 11: design problems for transformers, magnets and electromagnets, synchronous generators and condensers on a grid, induction motors from their tests and curves, induction generators and machine sizing"
eyebrow: S12 · Problem set 11
type: problems
---

::: hook
Each problem starts from a specification or a test report and asks for the choice an engineer would make: which transformer, how much magnet, how much field current, how much rotor resistance, how much capacitance. They draw on the whole course, mostly on the first two thirds. Write down the requirement before reaching for a formula.
:::

::: pool
pick: 12

::: check
kind: parts
given: S = 50 | 500; c = 0.2 | 0.4; u = 0.8 | 1.4; h = 6 | 12; x = 0.15 | 0.3; p = 0.85 | 0.95

## A {S} kVA transformer with core loss {c}% and full-load copper loss {u}% of its rating runs {h} hours a day at full load and the rest at {x} of full load, all at power factor {p}.

::: part
answer: (h + (24 - h)*x)*S*p/((h + (24 - h)*x)*S*p + 24*c/100*S + (h + (24 - h)*x^2)*u/100*S)*100
unit: %
tolerance: 0.5%

### What is its all-day efficiency?

::: misses
- [any] Energy out over energy out plus core loss all day plus copper loss by load squared.
:::
:::

::: part
answer: sqrt(c/u)
tolerance: 0.5%

### At what load fraction would it be most efficient?

::: misses
- [any] $\sqrt{P_c/P_{cu}}$.
:::
:::
:::

::: check
kind: parts
given: B = 1.1 | 1.3; G = 0.4 | 0.6 | 0.8; g = 0.5 | 1.5; A = 5 | 20

## A {g} mm × {A} cm² gap needs {G} T from an NdFeB magnet with $B_r$ = {B} T and $\mu_r$ = 1.05, operated at its maximum energy product.

::: part
answer: B^2/(4*4*pi*1e-7*1.05)/1e3
unit: kJ/m^3
tolerance: 0.5%

### What is that energy product?

::: misses
- [any] $B_r^2/(4\mu_0\mu_r)$.
:::
:::

::: part
answer: G^2*g*1e-3*A*1e-4/(4*pi*1e-7*B^2/(4*4*pi*1e-7*1.05))*1e6
unit: cm^3
tolerance: 0.5%

### What magnet volume does it need?

::: misses
- [any] $B_g^2V_g/(\mu_0(BH)_\max)$.
:::
:::
:::

::: check
kind: parts
given: m = 5 | 20 | 100; A = 4 | 10 | 25; g = 0.3 | 0.8; s = 1.5 | 2

## An electromagnet must hold {m} kg with a safety factor of {s}, across two poles of {A} cm² each and {g} mm of air at each.

::: part
answer: sqrt(2*4*pi*1e-7*s*m*9.81/(2*A*1e-4))
unit: T
tolerance: 0.5%

### What gap flux density does it need?

::: misses
- [any] $B^2A_\text{tot}/2\mu_0 = s\,mg$.
:::
:::

::: part
answer: sqrt(2*4*pi*1e-7*s*m*9.81/(2*A*1e-4))*2*g*1e-3/(4*pi*1e-7)
unit: A
tolerance: 0.5%

### How many ampere-turns?

::: misses
- [any] $B \cdot 2g/\mu_0$.
:::
:::
:::

::: check
kind: parts
given: X = 0.8 | 1.1 | 1.5; p = 0.8 | 0.9; F = 2 | 5

## A generator ($X_s$ = {X} pu, saturated) needs {F} A of field for rated voltage on its modified air-gap line, and delivers rated current at {p} power factor lagging.

::: part
answer: sqrt((1 + X*sqrt(1 - p^2))^2 + (X*p)^2)*F
unit: A
tolerance: 0.5%

### Approximately what field current does it need?

::: misses
- [F] Rated voltage alone isn't enough under load.
- [any] $E_f$ in per unit times the field for rated voltage.
:::
:::

::: part
answer: 1/sqrt((1 + X*sqrt(1 - p^2))^2 + (X*p)^2)*X*p
tolerance: 0.5%

### What fraction of its pull-out power is it then delivering?

::: misses
- [any] $\sin\delta$, since $P/P_\max = \sin\delta$.
:::
:::
:::

::: check
kind: parts
given: S = 20 | 100 | 250; Q = 0.3 | 0.5 | 0.8; X = 0.9 | 1.3

## A synchronous condenser rated {S} MVA ($X_s$ = {X} pu) on a 1 pu bus must supply {Q} pu of reactive power.

::: part
answer: 1 + Q*X
tolerance: 0.5%

### What excitation does it need?

::: misses
- [any] $Q = (E_f - V)V/X_s$.
:::
:::

::: part
answer: Q*S
unit: Mvar
tolerance: 0.5%

### How much is that in megavars?

::: misses
- [any] Times the rating.
:::
:::
:::

::: check
kind: parts
given: E = 1.3 | 1.6; X = 1 | 1.3; e = 0.2 | 0.5; q = 0.5 | 0.7; H = 3 | 6

## A 60 Hz generator ($E_f$ = {E}, $X_s$ = {X} pu, H = {H} s) delivers {q} of its pull-out power to a 1 pu bus through {e} pu of external reactance.

::: part
answer: E/(X + e)*q
tolerance: 0.5%

### How much power does it deliver, in per unit?

::: misses
- [any] $q E_f/(X_s + X_e)$.
:::
:::

::: part
answer: sqrt(377*E/(X + e)*sqrt(1 - q^2)/(2*H))/(2*pi)
unit: Hz
tolerance: 0.5%

### At what frequency does it swing?

::: misses
- [any] $\sqrt{\omega_sP_s/2H}/2\pi$ with $P_s = P_\max\cos\delta$.
:::
:::
:::

::: check
kind: parts
given: I = 20 | 60; z = 0.4 | 0.8 | 1.5; a = 0.5 | 0.7; r = 0.05 | 0.15; f = 15 | 20; let v = z*I; let P = 3*I^2*a*z

## A Y-connected 60 Hz motor's DC test gives $R_1$ = {r} Ω. Its blocked-rotor test at {f} Hz takes {I} A at {v} V per phase and {P} W.

::: part
answer: P/(3*I^2) - r
unit: Ω
tolerance: 0.5%

### What is $R_2$?

::: misses
- [P/(3*I^2)] Subtract the stator's resistance.
- [any] $P/(3I^2) - R_1$.
:::
:::

::: part
answer: sqrt((v/I)^2 - (P/(3*I^2))^2)*60/f
unit: Ω
tolerance: 0.5%

### What is $X_1 + X_2$ at 60 Hz?

::: misses
- [sqrt((v/I)^2 - (P/(3*I^2))^2)] Scale the test-frequency reactance to 60 Hz.
- [any] $\sqrt{|Z|^2 - R^2}$ times 60/f.
:::
:::
:::

::: check
kind: parts
given: R = 0.1 | 0.3; X = 0.8 | 1.2; r = 0.08 | 0.15; V = 230 | 260

## A 4-pole, 60 Hz motor's Thévenin circuit is {V} V behind {R} Ω with {X} Ω of total leakage; its rotor resistance is {r} Ω.

::: part
answer: sqrt(R^2 + X^2) - r
unit: Ω
tolerance: 0.5%

### What external rotor resistance (referred) gives breakdown torque at standstill?

::: misses
- [sqrt(R^2 + X^2)] Subtract the rotor's own resistance.
- [any] $\sqrt{R_\text{th}^2 + X^2} - R_2$.
:::
:::

::: part
answer: 1.5*V^2/(188.5*(R + sqrt(R^2 + X^2)))
unit: N·m
tolerance: 0.5%

### What starting torque does that give?

::: misses
- [any] The breakdown torque, independent of rotor resistance.
:::
:::
:::

::: check
kind: parts
given: V = 230 | 460; R = 0.1 | 0.3; x = 0.4 | 0.8; r = 0.1 | 0.3; s = 0.02 | 0.04

## An induction motor on {V} V (line, Y) has $R_1$ = {R}, $X_1 = X_2$ = {x} and $R_2$ = {r} Ω, at slip {s}. Use the approximate circuit with the magnetizing branch at the terminals.

::: part
answer: V/sqrt(3)/sqrt((R + r/s)^2 + (2*x)^2)
unit: A
tolerance: 0.5%

### What rotor current flows?

::: misses
- [any] Phase voltage over $|R_1 + R_2/s + j(X_1 + X_2)|$.
:::
:::

::: part
answer: 3*(V/sqrt(3))^2/((R + r/s)^2 + (2*x)^2)*r/s
unit: W
tolerance: 0.5%

### What air-gap power?

::: misses
- [any] $3I_2^2R_2/s$.
:::
:::
:::

::: check
kind: parts
given: X = 15 | 25 | 40; f = 50 | 60

## An induction generator with $X_m$ = {X} Ω per phase is to self-excite on {f} Hz.

::: part
answer: 1/(2*pi*f*X)*1e6
unit: µF
tolerance: 0.5%

### What capacitance per phase, in Y?

::: misses
- [any] $1/(\omega X_m)$.
:::
:::

::: part
answer: 1/(2*pi*f*X)*1e6/3
unit: µF
tolerance: 0.5%

### And in Δ?

::: misses
- [any] A third, at √3 times the voltage.
:::
:::
:::

::: check
kind: parts
given: P = 11 | 55 | 250; p = 2 | 4 | 6; f = 50 | 60; s = 18 | 30; r = 1 | 1.5

## A {P} kW, {p}-pole, {f} Hz induction motor (about 3% slip) is sized for a {s} kPa shear stress and a length-to-diameter ratio of {r}.

::: part
answer: P*1e3/(120*f/p*0.97*2*pi/60)
unit: N·m
tolerance: 0.5%

### What torque must it make?

::: misses
- [any] Power over speed, at 97% of synchronous.
:::
:::

::: part
answer: (2*P*1e3/(120*f/p*0.97*2*pi/60)/(pi*s*1e3*r))^(1/3)
unit: m
tolerance: 0.5%

### What rotor diameter?

::: misses
- [any] $T = \frac\pi2\sigma D^3(l/D)$.
:::
:::
:::

::: check
kind: parts
given: a = 455 | 462; b = 468 | 475; c = 445 | 450; k = 6 | 7.5; I = 50 | 200

## A motor rated {I} A (locked-rotor current {k} times rated) sees line voltages of {a}, {b} and {c} V.

::: part
answer: sqrt((1 - sqrt(3 - 6*(a^4 + b^4 + c^4)/(a^2 + b^2 + c^2)^2))/(1 + sqrt(3 - 6*(a^4 + b^4 + c^4)/(a^2 + b^2 + c^2)^2)))*100
unit: %
tolerance: 0.5%

### What is the true voltage unbalance?

::: misses
- [any] From β of the magnitudes.
:::
:::

::: part
answer: k*sqrt((1 - sqrt(3 - 6*(a^4 + b^4 + c^4)/(a^2 + b^2 + c^2)^2))/(1 + sqrt(3 - 6*(a^4 + b^4 + c^4)/(a^2 + b^2 + c^2)^2)))*I
unit: A
tolerance: 0.5%

### About how much negative-sequence current does it draw?

::: misses
- [any] $(I_\text{lr}/I_\text{rated})uI_\text{rated}$.
:::
:::
:::

::: check
kind: parts
given: P = 2 | 3.6 | 6; r = 0.25 | 0.3 | 0.35

## A doubly fed wind generator rated {P} MW at the grid must cover a speed range of ±{r}.

::: part
answer: r*P/(1 + r)
unit: MW
tolerance: 0.5%

### What must its converter carry at top speed and full output?

::: misses
- [r*P] The stator carries $P/(1 + r)$; the converter $r$ of that.
- [any] $|s|P/(1 - s)$ with s = −r.
:::
:::
:::

::: check
kind: parts
given: x = 0.9 | 1.2; y = 0.55 | 0.7; p = 0.8 | 0.9

## A salient-pole generator ($X_d$ = {x}, $X_q$ = {y} pu) delivers rated current at power factor {p} lagging to a 1 pu bus.

::: part
answer: sqrt((1 + y*sqrt(1 - p^2))^2 + (y*p)^2) + (x - y)*sin(atan(y*p/(1 + y*sqrt(1 - p^2))) + acos(p))
tolerance: 0.5%

### What excitation does it need?

::: misses
- [any] $|E'| + (X_d - X_q)I_d$.
:::
:::

::: part
answer: atan(y*p/(1 + y*sqrt(1 - p^2)))*180/pi
unit: °
tolerance: 0.5%

### At what load angle?

::: misses
- [any] The angle of $\hat V + jX_q\hat I$.
:::
:::
:::
::: check
kind: parts
given: L = 500 | 2000; p = 0.7 | 0.8; m = 100 | 400

## A plant draws {L} kW at {p} power factor lagging. A synchronous motor that will drive a new {m} kW load is to be overexcited so that the plant's total power factor becomes 1.

::: part
answer: L*tan(acos(p))
unit: kvar
tolerance: 0.5%

### How much reactive power must the motor supply?

::: misses
- [any] $P\tan\phi$ of the existing load.
:::
:::

::: part
answer: sqrt(m^2 + (L*tan(acos(p)))^2)
unit: kVA
tolerance: 0.5%

### What apparent power must the motor be rated for?

::: misses
- [m] It carries the reactive power too.
- [any] $\sqrt{P_m^2 + Q^2}$.
:::
:::

::: part
answer: m/sqrt(m^2 + (L*tan(acos(p)))^2)
tolerance: 0.5%

### At what leading power factor does it run?

::: misses
- [any] $P_m/S_m$.
:::
:::
:::
:::