S12 · Problem set 12
Problem set 12: design problems for variable-speed drives, vector-controlled induction and PM motors, mechanical loads and duty cycles, cables and insulation, and linear and positioning actuators
The last set before the final asks for drive and actuator designs: the voltage a drive needs at low speed, the flux it uses above base speed, the gearbox that gets a load moving soonest, the rise time that keeps a cable short, the gains that hold a magnet in the air. They pull together the second half of the course with the first.
Check
A motor rated 250 N·m at its 50 Hz base, with 700 N·m of breakdown torque, is run at 70 Hz with rated voltage.
(a)
What torque can it carry at rated current?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
About what breakdown torque remains (ignoring stator resistance)?
Check
A 4-pole induction motor ( = 1.03, = 0.1 Ω) runs under field orientation at 0.9 Wb and = 45 A, at 900 rpm.
(a)
What slip frequency (electrical) does the drive impose?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
At what frequency does the inverter run?
Check
A 6-pole surface PM motor ( = 0.06 Wb, L = 0.3 mH, rated 100 A) runs on 300 V peak per phase.
(a)
What torque does it make at rated current below base speed?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Up to what speed can it hold that torque?
Check
A conveyor's drum (0.2 kg·m²) must reach 150 rad/s as quickly as possible, driven by a motor of 0.002 kg·m² making 20 N·m through a gearbox.
(a)
What gear ratio?
(b)
How long does the drum take to reach speed (no load torque)?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A 15 kW fan runs half its 6000 hours a year at 0.5 and half at 1 of full speed under a drive. Electricity costs 0.12 dollars per kWh.
(a)
How much energy does it use per year?
Write units the way you normally would: 1.5 kWh, 1500 Wh and 0.0015 MWh are the same answer.
(b)
What does that save against running at full speed all year?
Check
A motor is fed through 50 m of cable carrying waves at 150 m/µs. A filter is to slow the drive's edges enough that the cable no longer acts as long.
(a)
What rise time must the filter give at least?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
A servo's cycle: 50 N·m for 2 s accelerating, 40 N·m for 30 s running, then 5 s stopped.
(a)
What continuous torque rating does it need?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What peak torque must it be able to make?
Check
A series traction motor on 600 V with 0.05 Ω runs at 1000 rpm drawing 400 A on level track; on a grade it draws 1.5 times as much. Ignore saturation.
(a)
How fast does it run on the grade?
(b)
By what factor does its torque rise?
Check
A drone motor rated 500 rpm/V with 0.1 Ω runs from 22 V, with its drive limited to 80 A.
(a)
What torque does it make at the current limit?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What is the highest speed at which it can still draw that current?
Check
A table is driven by a 50-tooth hybrid stepper through a 2 mm-lead screw, with 16 microsteps per step, at up to 200 mm/s.
(a)
What linear resolution does a microstep give?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
(b)
What full-step rate does top speed need?
Check
A voice coil ( = 4 N/A, 1 Ω) must accelerate 0.3 kg at 100 m/s² without dissipating more than 5 W.
(a)
What does it dissipate at that acceleration?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is the most acceleration the heat limit allows?
Check
A maglev magnet holds 200 kg at an 8 mm gap with 30 A. The controller should place its poles at 150 rad/s with damping 0.7.
(a)
What proportional gain?
Write units the way you normally would: 1.5 A/m, 1500 mA/m and 0.0015 kA/m are the same answer.
(b)
What derivative gain?
Check
A linear induction motor with a 0.2 m pole pitch must move a vehicle at 10 m/s with slip 0.12.
(a)
What supply frequency does it need?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A motor's hot spot runs at 120 °C under a class 155 °C insulation; a duty change would raise it 20 K.
(a)
What relative life does it have now?
(b)
By what factor would the change shorten its life?
Check
A drive keeps a 400 V motor at constant volts per hertz below base speed. At 0.1 of base frequency the motor draws 50 A through 0.5 Ω of stator resistance per phase.
(a)
What phase voltage does strict V/f give?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Roughly how large is the resistive drop as a percentage of that voltage?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.