title: "Problem set 2: windings, fields, voltage, torque and the synchronous machine"
heading: "Problem set 2: winding factors and MMF, rotating fields and synchronous speed, generated voltage and torque, and the synchronous machine's equivalent circuit"
eyebrow: S12 · Problem set 2
type: problems
---

::: hook
These problems cover lessons 7 to 10: pitch and distribution factors, the MMF of a phase and of three, synchronous speed, flux per pole and induced voltage, torque from fields and from shear stress, and the synchronous machine's excitation voltage, load angle and power.
:::

::: pool
pick: 12

::: check
kind: parts
given: q = 2 | 3 | 4; r = 0.8 | 0.833 | 0.889

## A three-phase winding with q = {q} slots per pole per phase and {r} pitch.

::: part
answer: sin(r*pi/2)
tolerance: 0.5%

### Pitch factor?

::: misses
- [any] $\sin(\rho\pi/2)$.
:::
:::

::: part
answer: sin(pi/6)/(q*sin(pi/(6*q)))
tolerance: 0.2%

### Distribution factor?

::: misses
- [any] $\sin(q\gamma/2)/(q\sin(\gamma/2))$, γ = 60°/q.
:::
:::

::: part
answer: abs(sin(7*r*pi/2)*sin(7*pi/6)/(q*sin(7*pi/(6*q))))
tolerance: 0.5%

### Winding factor for the 7th harmonic?

::: misses
- [any] Both factors with the angles multiplied by 7.
:::
:::
:::

::: check
kind: parts
given: N = 24 | 60; k = 0.9 | 0.94; P = 4 | 6; i = 5 | 15; g = 1 | 2

## A {P}-pole three-phase winding: {N} series turns per phase, $k_w$ = {k}, {i} A RMS, a {g} mm gap.

::: part
answer: 4/pi*k*N/P*i*sqrt(2)
unit: A
tolerance: 0.5%

### Peak MMF per pole of one phase (A·turns)?

::: misses
- [any] $\frac{4}{\pi}\frac{k_wN}{P}\sqrt{2}I$.
:::
:::

::: part
answer: 1.5*4/pi*k*N/P*i*sqrt(2)
unit: A
tolerance: 0.5%

### Rotating MMF amplitude (A·turns)?

::: misses
- [any] 3/2 of one phase.
:::
:::

::: part
answer: 4e-7*pi*1.5*4/pi*k*N/P*i*sqrt(2)/(g*1e-3)
unit: T
tolerance: 0.5%

### Peak gap flux density?

::: misses
- [any] $\mu_0F/g$.
:::
:::
:::

::: check
kind: parts
given: f = 50 | 60 | 400; P = 2 | 4 | 8

## A {P}-pole machine on {f} Hz.

::: part
answer: 120*f/P
unit: rpm
tolerance: 0.5%

### Synchronous speed?

::: misses
- [any] $120f/P$.
:::
:::

::: part
answer: 4*pi*f/P
unit: rad/s
tolerance: 0.5%

### In mechanical rad/s?

::: misses
- [any] $2\omega_e/P$.
:::
:::
:::

::: check
kind: parts
given: a = 4 | 10; b = 2 | 6 | 14; F = 300 | 800

## A two-phase motor's windings carry quadrature currents of {a} A and {b} A peak; separately, a single-phase winding pulses with {F} A·turns peak.

::: part
answer: (a + b)/2
unit: A
tolerance: 0.5%

### Forward field in amperes of winding current?

::: misses
- [any] $(I_a + I_b)/2$.
:::
:::

::: part
answer: abs(a - b)/2
unit: A
tolerance: 0.5%

### Backward?

::: misses
- [any] $|I_a - I_b|/2$.
:::
:::

::: part
answer: F/2
unit: A
tolerance: 0.5%

### Each rotating component of the single-phase MMF (A·turns)?

::: misses
- [any] Half.
:::
:::
:::

::: check
kind: parts
given: P = 2 | 4; B = 0.7 | 1; l = 0.15 | 0.5; r = 0.08 | 0.25; f = 50 | 60; N = 24 | 72; k = 0.92 | 0.95

## A {P}-pole machine: rotor radius {r} m, length {l} m, gap field {B} T peak, {N} series turns per phase with $k_w$ = {k}, at {f} Hz.

::: part
answer: 4/P*B*l*r
unit: Wb
tolerance: 0.5%

### Flux per pole?

::: misses
- [any] $\frac{4}{P}Blr$.
:::
:::

::: part
answer: sqrt(2)*pi*f*k*N*4/P*B*l*r
unit: V
tolerance: 0.5%

### Phase voltage (RMS)?

::: misses
- [any] $4.44fk_wN\Phi$.
:::
:::

::: part
answer: sqrt(3)*sqrt(2)*pi*f*k*N*4/P*B*l*r
unit: V
tolerance: 0.5%

### Line voltage (Y)?

::: misses
- [any] √3 times.
:::
:::
:::

::: check
kind: parts
given: s = 10 | 30; D = 0.15 | 0.5; l = 0.1 | 0.5; n = 1500 | 3000

## A rotor of {D} m diameter and {l} m length at {s} kPa shear stress, turning at {n} rpm.

::: part
answer: 2*s*1e3*pi*(D/2)^2*l
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] $2\sigma V_r$.
:::
:::

::: part
answer: 2*s*1e3*pi*(D/2)^2*l*2*pi*n/60/1000
unit: kW
tolerance: 0.5%

### Power?

::: misses
- [any] $T\omega$.
:::
:::
:::

::: check
kind: parts
given: P = 2 | 4 | 6; F = 0.03 | 0.1; R = 400 | 1500; d = 25 | 60

## A {P}-pole machine: $\Phi_{sr}$ = {F} Wb, $F_r$ = {R} A·turns per pole, $\delta_r$ = {d}°.

::: part
answer: pi/2*(P/2)^2*F*R*sin(d*pi/180)
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] $\frac{\pi}{2}(P/2)^2\Phi F\sin\delta$.
:::
:::

::: part
answer: pi/2*(P/2)^2*F*R
unit: N·m
tolerance: 0.5%

### Largest torque at these field strengths?

::: misses
- [any] At 90°.
:::
:::
:::

::: check
kind: parts
given: x = 0.7 | 1.2 | 1.7; i = 0.6 | 1; p = 0.8 | 0.95

## A generator with $X_s$ = {x} pu supplies {i} pu at power factor {p} lagging, 1 pu terminal voltage.

::: part
answer: sqrt((1 + x*i*sqrt(1 - p^2))^2 + (x*i*p)^2)
tolerance: 0.5%

### $E_f$?

::: misses
- [any] $|V + jX_sI|$.
:::
:::

::: part
answer: atan(x*i*p/(1 + x*i*sqrt(1 - p^2)))*180/pi
unit: °
tolerance: 0.5%

### Load angle?

::: misses
- [any] Angle of $E_f$.
:::
:::

::: part
answer: sqrt((1 + x*i*sqrt(1 - p^2))^2 + (x*i*p)^2)/x
tolerance: 0.5%

### Pull-out power at this excitation, per unit?

::: misses
- [any] $VE_f/X_s$.
:::
:::
:::

::: check
kind: parts
given: x = 0.7 | 1 | 1.2; i = 0.6 | 1; p = 0.8 | 0.95

## The same kind of generator ($X_s$ = {x} pu, {i} pu current) at power factor {p} leading.

::: part
answer: sqrt((1 - x*i*sqrt(1 - p^2))^2 + (x*i*p)^2)
tolerance: 0.5%

### $E_f$?

::: misses
- [any] The reactive drop now subtracts from V.
:::
:::

::: part
answer: atan(x*i*p/(1 - x*i*sqrt(1 - p^2)))*180/pi
unit: °
tolerance: 0.5%

### Load angle?

::: misses
- [any] Angle of $V + jX_sI$ with I leading.
:::
:::
:::

::: check
kind: parts
given: V = 460 | 2300; P = 20 | 150; X = 1.5 | 6

## A synchronous motor on {V} V line to line, $X_s$ = {X} Ω per phase, taking {P} kW at unity power factor.

::: part
answer: P*1000/(sqrt(3)*V)
unit: A
tolerance: 0.5%

### Current?

::: misses
- [any] $P/(\sqrt{3}V_{LL})$.
:::
:::

::: part
answer: sqrt((V/sqrt(3))^2 + (X*P*1000/(sqrt(3)*V))^2)
unit: V
tolerance: 0.5%

### Excitation voltage per phase?

::: misses
- [any] $|V - jX_sI|$.
:::
:::

::: part
answer: atan(X*P*1000/(sqrt(3)*V)/(V/sqrt(3)))*180/pi
unit: °
tolerance: 0.5%

### Load angle magnitude?

::: misses
- [any] $\tan^{-1}(X_sI/V)$.
:::
:::
:::

::: check
kind: parts
given: x = 0.9 | 1.5; V = 13.8 | 20; S = 100 | 500; E = 1.3 | 1.7; d = 20 | 40

## A {S} MVA, {V} kV generator with $X_s$ = {x} pu runs at $E_f$ = {E} pu, δ = {d}°.

::: part
answer: x*V^2/S
unit: Ω
tolerance: 0.5%

### $X_s$ in ohms per phase?

::: misses
- [any] $xV^2/S$.
:::
:::

::: part
answer: E*sin(d*pi/180)/x*S
unit: MW
tolerance: 0.5%

### Real power?

::: misses
- [any] $(E_f\sin\delta/X_s)S_\text{base}$.
:::
:::
:::

::: check
kind: parts
given: f = 50 | 60; k = 1 | 2 | 3 | 4; P = 100 | 2000; let n = 60*f/k

## A machine on {f} Hz must turn at {n} rpm and deliver {P} kW.

::: part
answer: 120*f/n
tolerance: 0.5%

### Poles?

::: misses
- [any] $120f/n$.
:::
:::

::: part
answer: P*1000/(2*pi*n/60)
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] $P/\omega$.
:::
:::
:::

::: check
kind: parts
given: Q = 36 | 54 | 72; P = 4 | 6; y = 0.778 | 0.833

## A three-phase winding has {Q} slots, {P} poles and a pitch of {y}.

::: part
answer: 2*Q/(3*P)*3 - 1
tolerance: 0.5%

### What is the order of its lower slot harmonic?

::: misses
- [any] $6q - 1$.
:::
:::

::: part
answer: abs(sin((6*Q/(3*P) - 1)*pi/6)/(Q/(3*P)*sin((6*Q/(3*P) - 1)*pi/(6*Q/(3*P))))*sin((6*Q/(3*P) - 1)*y*pi/2))
tolerance: 1%

### What is its winding factor for that harmonic?

::: misses
- [any] The distribution factor repeats the fundamental's; check the pitch factor.
:::
:::
:::

::: check
kind: parts
given: P = 2 | 4 | 6; B = 0.6 | 0.9; r = 0.08 | 0.25; l = 0.15 | 0.5; N = 20 | 80; k = 0.92 | 0.96; f = 50 | 60

## A {P}-pole, {f} Hz machine (rotor radius {r} m, length {l} m) has a {B} T peak gap field and {N} turns per phase, $k_w$ = {k}.

::: part
answer: 4/P*B*l*r
unit: Wb
tolerance: 0.5%

### What is its flux per pole?

::: misses
- [any] $(4/P)\hat Blr$.
:::
:::

::: part
answer: sqrt(2)*pi*f*k*N*4/P*B*l*r
unit: V
tolerance: 0.5%

### What phase voltage does it generate?

::: misses
- [any] $\sqrt2\pi fk_wN\Phi_p$.
:::
:::
:::

::: check
kind: parts
given: X = 0.8 | 1.2 | 1.6; p = 0.8 | 0.9

## A round-rotor generator ($X_s$ = {X} pu) delivers rated current at rated voltage and power factor {p} leading.

::: part
answer: sqrt((1 - X*sqrt(1 - p^2))^2 + (X*p)^2)
tolerance: 0.5%

### What excitation does it need?

::: misses
- [sqrt((1 + X*sqrt(1 - p^2))^2 + (X*p)^2)] Leading current lowers the excitation.
- [any] $|1 + jX_s\hat I|$ with $\hat I = p + j\sqrt{1 - p^2}$.
:::
:::
:::
:::