S12 Electric machines · Practice
Problem set 3: torque, windings and machine sizing
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A machine's windings carry 5 A (stator) and 6 A (rotor), DC, with (M = 0.2 H) and ( = 0.15 H).
(a)
How large is the torque at θ = −25°, pulling toward alignment?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What percentage of it is reluctance torque?
Check
A three-phase winding has 48 slots, 4 poles and coils pitched at 0.9 of a pole pitch.
(a)
What is its 5th-harmonic winding factor?
(b)
How large is the 5th-harmonic MMF, as a percentage of the fundamental's?
Check
A three-phase winding has 120 series turns per phase, = 0.92, 6 poles, and carries balanced currents of 50 A RMS across a 0.5 mm gap.
(a)
What is the peak of its rotating fundamental MMF, in ampere-turns per pole?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What peak flux density does it drive across the gap (ideal iron)?
Check
Three phase currents have magnitudes 1, 0.5 and 0.3 (per unit) and the normal 120° spacing.
(a)
What is the positive-sequence current?
(b)
What is the negative-sequence current?
Check
A 2-pole, 50 Hz machine has a rotor of radius 0.2 m and length 0.1 m, a 0.9 T peak gap field, and 30 turns per phase with = 0.93.
(a)
What RMS voltage does each phase generate?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What line voltage in Y?
Check
A machine with 2 slots per pole per phase and coils pitched at 1 has a gap field whose 3rd and 5th harmonics are 0.1 and 0.05 of its fundamental.
(a)
How large is the 3rd harmonic of its phase voltage, relative to the fundamental?
(b)
And the 5th, which also appears in the line voltage?
Check
A 160 kW, 3000 rpm machine is designed for 25 kA/m and 0.8 T, with a length-to-diameter ratio of 1.
(a)
What shear stress do the loadings give?
Write units the way you normally would: 1.5 kPa, 1500 Pa and 0.0015 MPa are the same answer.
(b)
What rotor diameter does it need?
Check
A motor running at 4 A/mm² is scaled up by 2 in every dimension and must keep the same temperature rise.
(a)
What current density can it use?
Write units the way you normally would: 1.5 A/mm^2, 1500 mA/mm^2 and 0.0015 kA/mm^2 are the same answer.
(b)
By what factor does its torque grow?
Check
A single-phase 50 Hz stator carries 5 A peak; the rotor, with 10 A DC, turns synchronously 80° behind the current, with mutual inductance peak 0.3 H.
(a)
What average torque does it develop?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
At what frequency does its torque pulsate?
Check
A 4-pole machine runs on 50 Hz.
(a)
What is its synchronous speed?
(b)
How many electrical degrees does 30 mechanical degrees span?
Check
A rotor 0.2 m in diameter and 1.5 times as long sustains a shear stress of 20 kPa at 1800 rpm.
(a)
What torque does it make?
Write units the way you normally would: 1.5 kN·m, 1500 N·m and 0.0015 MN·m are the same answer.
(b)
What power?
Check
A 4-pole, single-layer, full-pitch winding has 24 slots with 8 conductors each, carrying balanced currents of 15 A peak.
(a)
How many series turns per phase does it have?
(b)
What fundamental MMF per pole does it make?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A 6-pole, 50 Hz machine with a 0.15 m rotor, 1 times as long, a 0.9 T peak field and = 0.93 must generate 400 V per phase.
(a)
How many series turns per phase (before rounding)?
Check
A salient rotor with no winding sits in a stator coil of 0.5 A whose inductance varies as , = 0.05 H.
(a)
How large is the torque at θ = 70°?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What is the largest torque it can feel?
Check
A two-phase motor's windings, 90° apart, carry currents 90° apart whose MMFs peak at 1 and 0.6 times 800 ampere-turns.
(a)
How strong is the forward field, in ampere-turns?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
And the backward field?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12