title: "Problem set 4: synchronous machines in operation and the induction machine"
heading: "Problem set 4: open- and short-circuit tests, V-curves and synchronous condensers, salient-pole machines, and the induction machine's slip, equivalent circuit and power flow"
eyebrow: S12 · Problem set 4
type: problems
---

::: hook
These problems cover lessons 15 to 20: reactances and short-circuit ratios from test data, excitation and reactive power at fixed load, two-reaction theory and reluctance power, and the induction machine from slip to torque. Where a problem gives no magnetizing reactance, use the approximate circuit with the magnetizing branch moved to the terminals, so that $I_2 = V/\sqrt{(R_1 + R_2/s)^2 + (X_1 + X_2)^2}$.
:::

::: pool
pick: 12

::: check
kind: parts
given: V = 480 | 4160; f = 2.5 | 4; r = 1.1 | 1.4; S = 100 | 2000; let b = f/r; let s = S*1000/(sqrt(3)*V*b)

## A {S} kVA, {V} V machine reaches rated voltage at {f} A of field current; its SCC rises {s} A per field ampere, and rated short-circuit current needs {b} A of field current.

::: part
answer: (V/sqrt(3))/(s*f)
unit: Ω
tolerance: 0.5%

### Saturated $X_s$?

::: misses
- [any] $(V/\sqrt{3})/I_\text{sc}$ at the same field current.
:::
:::

::: part
answer: f/b
tolerance: 0.5%

### Short-circuit ratio?

::: misses
- [any] The ratio of the two field currents.
:::
:::

::: part
answer: S*1000/(sqrt(3)*V)
unit: A
tolerance: 0.5%

### Rated current?

::: misses
- [any] $S/(\sqrt{3}V)$.
:::
:::
:::

::: check
kind: parts
given: P = 0.4 | 0.8; x = 0.7 | 1.1; E = 1.3 | 1.7

## A synchronous motor ($X_s$ = {x} pu) carries {P} pu on a 1 pu bus.

::: part
answer: sqrt(1 + (P*x)^2)
tolerance: 0.5%

### $E_f$ for unity power factor?

::: misses
- [any] $\sqrt{1 + (PX_s)^2}$.
:::
:::

::: part
answer: asin(P*x/E)*180/pi
unit: °
tolerance: 0.5%

### Load angle at $E_f$ = {E}?

::: misses
- [any] $\sin^{-1}(PX_s/E_f)$.
:::
:::

::: part
answer: (sqrt(E^2 - (P*x)^2) - 1)/x
tolerance: 0.5%

### Reactive power supplied then (negative if absorbed)?

::: misses
- [any] $(E_f\cos\delta - 1)/X_s$.
:::
:::
:::

::: check
kind: parts
given: x = 0.8 | 1.2; S = 25 | 150; E = 0.6 | 1.5

## A {S} MVA synchronous condenser with $X_s$ = {x} pu on a 1 pu bus.

::: part
answer: (E - 1)/x*S
unit: Mvar
tolerance: 0.5%

### Reactive power supplied at $E_f$ = {E} pu (negative if absorbed)?

::: misses
- [any] $(E_f - 1)/X_s \times S$.
:::
:::

::: part
answer: abs(E - 1)/x
tolerance: 0.5%

### Its current, per unit?

::: misses
- [any] $|E_f - V|/X_s$.
:::
:::
:::

::: check
kind: parts
given: a = 0.9 | 1.2; b = 0.55 | 0.7; p = 0.8 | 0.9; i = 0.7 | 1

## A salient-pole generator: $X_d$ = {a}, $X_q$ = {b} pu, delivering {i} pu at power factor {p} lagging on a 1 pu bus.

::: part
answer: atan(b*i*p/(1 + b*i*sqrt(1 - p^2)))*180/pi
unit: °
tolerance: 0.5%

### Load angle?

::: misses
- [any] Angle of $V + jX_qI$.
:::
:::

::: part
answer: i*sin(atan(b*i*p/(1 + b*i*sqrt(1 - p^2))) + acos(p))
tolerance: 0.5%

### $I_d$?

::: misses
- [any] $I\sin(\delta + \phi)$.
:::
:::

::: part
answer: sqrt((1 + b*i*sqrt(1 - p^2))^2 + (b*i*p)^2) + (a - b)*i*sin(atan(b*i*p/(1 + b*i*sqrt(1 - p^2))) + acos(p))
tolerance: 0.5%

### $E_f$?

::: misses
- [any] $|E'| + (X_d - X_q)I_d$.
:::
:::
:::

::: check
kind: parts
given: E = 1.2 | 1.7; a = 0.9 | 1.3; b = 0.5 | 0.75; d = 20 | 45

## A salient-pole machine: $E_f$ = {E}, $X_d$ = {a}, $X_q$ = {b} pu on a 1 pu bus at δ = {d}°.

::: part
answer: E/a*sin(d*pi/180)
tolerance: 0.5%

### Field term?

::: misses
- [any] $VE_f\sin\delta/X_d$.
:::
:::

::: part
answer: (a - b)/(2*a*b)*sin(2*d*pi/180)
tolerance: 0.5%

### Reluctance term?

::: misses
- [any] $\frac{V^2(X_d - X_q)}{2X_dX_q}\sin 2\delta$.
:::
:::
:::

::: check
kind: parts
given: f = 50 | 60; P = 4 | 6; r = 0.02 | 0.04; M = 15 | 75

## A {P}-pole, {f} Hz induction motor runs at slip {r} and develops {M} kW of mechanical power.

::: part
answer: 120*f/P*(1 - r)
unit: rpm
tolerance: 0.5%

### Speed?

::: misses
- [any] $(1 - s)n_s$.
:::
:::

::: part
answer: M/(1 - r)
unit: kW
tolerance: 0.5%

### Air-gap power?

::: misses
- [any] $P_\text{mech}/(1 - s)$.
:::
:::

::: part
answer: M/(1 - r)*1000/(4*pi*f/P)
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] $P_\text{ag}/\omega_s$.
:::
:::
:::

::: check
kind: parts
given: V = 230 | 460; R = 0.15 | 0.3; X = 0.8 | 1.5; r = 0.1 | 0.25; s = 0.02 | 0.04

## An induction motor on {V} V (line), approximate circuit: $R_1$ = {R} Ω, $R_2$ = {r} Ω, $X_1 + X_2$ = {X} Ω, at slip {s}.

::: part
answer: (V/sqrt(3))/sqrt((R + r/s)^2 + X^2)
unit: A
tolerance: 0.5%

### Rotor current?

::: misses
- [any] $V/\sqrt{(R_1 + R_2/s)^2 + X^2}$.
:::
:::

::: part
answer: 3*((V/sqrt(3))/sqrt((R + r/s)^2 + X^2))^2*r/s/1000
unit: kW
tolerance: 0.5%

### Air-gap power?

::: misses
- [any] $3I_2^2R_2/s$.
:::
:::

::: part
answer: 3*((V/sqrt(3))/sqrt((R + r/s)^2 + X^2))^2*r/1000
unit: kW
tolerance: 0.5%

### Rotor copper loss?

::: misses
- [any] $3I_2^2R_2$.
:::
:::
:::

::: check
kind: parts
given: V = 400 | 690; R = 0.1 | 0.25; X = 1 | 2; r = 0.12 | 0.3

## The approximate circuit: {V} V (line), $R_1$ = {R}, $R_2$ = {r}, $X_1 + X_2$ = {X} Ω, at standstill.

::: part
answer: (V/sqrt(3))/sqrt((R + r)^2 + X^2)
unit: A
tolerance: 0.5%

### Starting current?

::: misses
- [any] s = 1.
:::
:::

::: part
answer: 3*((V/sqrt(3))/sqrt((R + r)^2 + X^2))^2*r/1000
unit: kW
tolerance: 0.5%

### Air-gap power at start?

::: misses
- [any] $3I_2^2R_2$ with s = 1.
:::
:::
:::

::: check
kind: parts
given: A = 10 | 80; s = 0.015 | 0.05; t = 0.3 | 1.5; c = 0.4 | 1.2

## An induction motor: air-gap power {A} kW at slip {s}, rotational loss {t} kW, stator copper and core loss {c} kW.

::: part
answer: A*(1 - s) - t
unit: kW
tolerance: 0.5%

### Output?

::: misses
- [any] $(1 - s)P_\text{ag}$ less rotational loss.
:::
:::

::: part
answer: 100*(A*(1 - s) - t)/(A + c)
unit: %
tolerance: 0.5%

### Efficiency?

::: misses
- [any] Output over air-gap power plus stator losses.
:::
:::
:::

::: check
kind: parts
given: v = 20 | 60; r = 0.55 | 0.75; I = 3 | 10; s = 0.6 | 0.8; let w = v*r; let m = I/s

## A slip test: phase voltage between {w} and {v} V, current between {I} and {m} A.

::: part
answer: v/I
unit: Ω
tolerance: 0.5%

### $X_d$?

::: misses
- [any] $V_\text{max}/I_\text{min}$.
:::
:::

::: part
answer: w/m
unit: Ω
tolerance: 0.5%

### $X_q$?

::: misses
- [any] $V_\text{min}/I_\text{max}$.
:::
:::
:::

::: check
kind: parts
given: f = 50 | 60; s = 0.01 | 0.04 | 0.07; P = 2 | 4

## A {P}-pole induction motor on {f} Hz at slip {s}.

::: part
answer: s*f
unit: Hz
tolerance: 0.5%

### Rotor frequency?

::: misses
- [any] $sf$.
:::
:::

::: part
answer: s*120*f/P
unit: rpm
tolerance: 0.5%

### Speed of the rotor's field relative to the rotor?

::: misses
- [any] $sn_s$.
:::
:::

::: part
answer: 100*(1 - s)
unit: %
tolerance: 0.5%

### Upper limit on rotor efficiency?

::: misses
- [any] $1 - s$.
:::
:::
:::

::: check
kind: parts
given: x = 0.7 | 1.2; P = 0.5 | 0.9; E = 1.1 | 1.5

## A round-rotor generator ($X_s$ = {x} pu, 1 pu bus) at $E_f$ = {E} pu delivering {P} pu.

::: part
answer: E/x
tolerance: 0.5%

### Pull-out power?

::: misses
- [any] $VE_f/X_s$.
:::
:::

::: part
answer: asin(P*x/E)*180/pi
unit: °
tolerance: 0.5%

### Load angle?

::: misses
- [any] $\sin^{-1}(PX_s/E_f)$.
:::
:::

::: part
answer: (E*sqrt(1 - (P*x/E)^2) - 1)/x
tolerance: 0.5%

### Reactive power delivered (negative if absorbed)?

::: misses
- [any] $(E_f\cos\delta - 1)/X_s$.
:::
:::
:::

::: check
kind: parts
given: a = 2 | 3.5; b = 1.8 | 2.8; S = 100 | 1000; V = 480 | 4160

## A {S} kVA, {V} V machine reaches rated voltage on its OCC at {a} A of field and rated current on its SCC at {b} A.

::: part
answer: b/a
tolerance: 0.5%

### What is its saturated synchronous reactance, in per unit?

::: misses
- [a/b] That's the short-circuit ratio; the reactance is its inverse.
- [any] 1/SCR.
:::
:::

::: part
answer: b/a*V^2/(S*1e3)
unit: Ω
tolerance: 0.5%

### And in ohms per phase?

::: misses
- [any] Per unit times the base impedance.
:::
:::
:::

::: check
kind: parts
given: E = 0.5 | 0.7 | 1.3 | 1.6; X = 0.8 | 1.2; S = 25 | 80

## A {S} MVA synchronous condenser ($X_s$ = {X} pu) runs at $E_f$ = {E} pu on a 1 pu bus.

::: part
answer: (E - 1)/X*S
unit: Mvar
tolerance: 0.5%

### What reactive power does it supply (negative if it absorbs)?

::: misses
- [any] $(E_f - V)V/X_s$ times the rating.
:::
:::
:::

::: check
kind: parts
given: n = 0.96 | 0.975; M = 15 | 75

## An induction motor runs at {n} of synchronous speed, delivering {M} kW of mechanical power.

::: part
answer: M/n
unit: kW
tolerance: 0.5%

### What air-gap power crosses to the rotor?

::: misses
- [any] $P_\text{mech}/(1 - s)$.
:::
:::

::: part
answer: M/n*(1 - n)
unit: kW
tolerance: 0.5%

### What is the rotor copper loss?

::: misses
- [any] $sP_\text{ag}$.
:::
:::
:::
:::