title: "Problem set 5: induction machine performance, tests, starting and speed control"
heading: "Problem set 5: the torque–speed characteristic, parameters from tests, starting methods and rotor design, induction generators, and speed control"
eyebrow: S12 · Problem set 5
type: problems
---

::: hook
These problems cover lessons 23 to 28: Thévenin reduction, breakdown and starting torque, rotor resistance, the DC, no-load and blocked-rotor tests, reduced-voltage starting, skin depth in rotor bars, induction generators and self-excitation, voltage sags and unbalance, variable-frequency and older speed control, and doubly fed generators.
:::

::: pool
pick: 12

::: check
kind: parts
given: V = 230 | 400; R = 0.1 | 0.25; X = 0.5 | 0.9; M = 15 | 30

## An induction motor: phase voltage {V} V, $R_1$ = {R} Ω, $X_1$ = {X} Ω, $X_m$ = {M} Ω.

::: part
answer: V*M/sqrt(R^2 + (X + M)^2)
unit: V
tolerance: 0.5%

### Thévenin voltage?

::: misses
- [any] $VX_m/|R_1 + j(X_1 + X_m)|$.
:::
:::

::: part
answer: R*M^2/(R^2 + (X + M)^2)
unit: Ω
tolerance: 0.5%

### Thévenin resistance?

::: misses
- [any] Real part of $jX_m(R_1 + jX_1)/(R_1 + j(X_1 + X_m))$.
:::
:::
:::

::: check
kind: parts
given: V = 150 | 260; R = 0.1 | 0.3; X = 0.8 | 1.6; r = 0.1 | 0.25; w = 125.66 | 188.5

## Thévenin source {V} V, $R_\text{th}$ = {R} Ω, $X_\text{th} + X_2$ = {X} Ω, $R_2$ = {r} Ω, $\omega_s$ = {w} rad/s.

::: part
answer: r/sqrt(R^2 + X^2)
tolerance: 0.5%

### Slip at breakdown?

::: misses
- [any] $R_2/|Z|$.
:::
:::

::: part
answer: 1.5*V^2/(w*(R + sqrt(R^2 + X^2)))
unit: N·m
tolerance: 0.5%

### Breakdown torque?

::: misses
- [any] $1.5V^2/(\omega_s(R + |Z|))$.
:::
:::

::: part
answer: 3*V^2*r/(w*((R + r)^2 + X^2))
unit: N·m
tolerance: 0.5%

### Starting torque?

::: misses
- [any] s = 1.
:::
:::
:::

::: check
kind: parts
given: V = 150 | 260; R = 0.1 | 0.3; X = 0.8 | 1.6; r = 0.1 | 0.25; w = 125.66 | 188.5; s = 0.02 | 0.04

## The same kind of motor ({V} V, $R_\text{th}$ = {R}, X = {X}, $R_2$ = {r} Ω, $\omega_s$ = {w}) at slip {s}.

::: part
answer: 3*V^2*(r/s)/(w*((R + r/s)^2 + X^2))
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] The full torque formula.
:::
:::

::: part
answer: sqrt(R^2 + X^2) - r
unit: Ω
tolerance: 0.5%

### Added rotor resistance for breakdown at standstill?

::: misses
- [any] $|Z| - R_2$.
:::
:::
:::

::: check
kind: parts
given: v = 8 | 20; d = 15 | 40; R = 0.1 | 0.3; I = 8 | 20; t = 400 | 1200; V = 400 | 460

## Motor tests: DC {v} V at {d} A; no load at {V} V line, {I} A, with {t} W of rotational loss.

::: part
answer: v/(2*d)
unit: Ω
tolerance: 0.5%

### $R_1$?

::: misses
- [any] $V/(2I)$.
:::
:::

::: part
answer: t + 3*I^2*v/(2*d)
unit: W
tolerance: 0.5%

### No-load input power?

::: misses
- [any] Rotational loss plus $3I^2R_1$.
:::
:::

::: part
answer: V/sqrt(3)/I
unit: Ω
tolerance: 0.5%

### $X_1 + X_m$?

::: misses
- [any] $V_\phi/I$.
:::
:::
:::

::: check
kind: parts
given: I = 25 | 70; R = 0.1 | 0.3; r = 0.1 | 0.3; X = 0.8 | 2; f = 15 | 20; let P = 3*I^2*(R + r); let V = sqrt(3)*I*sqrt((R + r)^2 + (X*f/60)^2)

## Blocked rotor at {f} Hz: {V} V line, {I} A, {P} W; $R_1$ = {R} Ω (class B).

::: part
answer: P/(3*I^2) - R
unit: Ω
tolerance: 0.5%

### $R_2$?

::: misses
- [any] $P/(3I^2) - R_1$.
:::
:::

::: part
answer: sqrt((V/sqrt(3)/I)^2 - (P/(3*I^2))^2)*60/f
unit: Ω
tolerance: 0.5%

### $X_1 + X_2$ at 60 Hz?

::: misses
- [any] Scale by 60/f.
:::
:::

::: part
answer: 0.4*sqrt((V/sqrt(3)/I)^2 - (P/(3*I^2))^2)*60/f
unit: Ω
tolerance: 0.5%

### $X_1$?

::: misses
- [any] 40% for class B.
:::
:::
:::

::: check
kind: parts
given: I = 5.5 | 7.5; T = 1.4 | 2.2; a = 0.5 | 0.65 | 0.8

## A motor draws {I} times rated current and {T} times rated torque direct on line.

::: part
answer: I/3
tolerance: 0.5%

### Wye–delta line current (× rated)?

::: misses
- [any] A third.
:::
:::

::: part
answer: a^2*I
tolerance: 0.5%

### Autotransformer at tap {a}, line current?

::: misses
- [any] $a^2I$.
:::
:::

::: part
answer: a^2*T
tolerance: 0.5%

### Its starting torque?

::: misses
- [any] $a^2T$.
:::
:::
:::

::: check
kind: parts
given: f = 50 | 60; s = 0.01 | 0.03; r = 2.8 | 3.2

## A rotor bar of resistivity {r} × 10⁻⁸ Ω·m on a {f} Hz supply.

::: part
answer: sqrt(2*r*1e-8/(2*pi*f*4e-7*pi))*1000
unit: mm
tolerance: 0.5%

### Skin depth at standstill?

::: misses
- [any] $\sqrt{2\rho/\omega\mu_0}$.
:::
:::

::: part
answer: sqrt(2*r*1e-8/(2*pi*s*f*4e-7*pi))*1000
unit: mm
tolerance: 0.5%

### At slip {s}?

::: misses
- [any] Use the slip frequency.
:::
:::
:::

::: check
kind: parts
given: f = 50 | 60; P = 4 | 6; r = 0.01 | 0.02 | 0.03; X = 12 | 30; let n = 120*f/P*(1 + r)

## An induction generator: {P} poles, {f} Hz, driven at {n} rpm, $X_m$ = {X} Ω.

::: part
answer: (120*f/P - n)/(120*f/P)
tolerance: 0.5%

### Slip?

::: misses
- [any] Negative above synchronous speed.
:::
:::

::: part
answer: 1/(2*pi*f*X)*1e6
unit: µF
tolerance: 0.5%

### Capacitance per phase to self-excite?

::: misses
- [any] $1/(\omega X_m)$.
:::
:::
:::

::: check
kind: parts
given: V = 400 | 460; b = 50 | 60; f = 15 | 35; P = 4 | 6; d = 20 | 50

## A {V} V, {b} Hz, {P}-pole motor on a constant-V/f drive at {f} Hz, needing {d} rpm of slip speed.

::: part
answer: V*f/b
unit: V
tolerance: 0.5%

### Drive voltage (no boost)?

::: misses
- [any] $Vf/f_b$.
:::
:::

::: part
answer: 120*f/P - d
unit: rpm
tolerance: 0.5%

### Speed?

::: misses
- [any] $n_s - \Delta n$.
:::
:::
:::

::: check
kind: parts
given: T = 150 | 600; M = 400 | 1500; b = 50 | 60; f = 80 | 110

## Base speed at {b} Hz: rated {T} N·m, breakdown {M} N·m. Field weakening at {f} Hz.

::: part
answer: T*b/f
unit: N·m
tolerance: 0.5%

### Torque at rated current?

::: misses
- [any] $T f_b/f$.
:::
:::

::: part
answer: M*(b/f)^2
unit: N·m
tolerance: 0.5%

### Breakdown torque (ignoring resistance)?

::: misses
- [any] $M(f_b/f)^2$.
:::
:::
:::

::: check
kind: parts
given: P = 4 | 6; f = 50 | 60; r = 0.2 | 0.4; M = 10 | 50; let n = 120*f/P*(1 - r)

## A wound-rotor motor ({P} poles, {f} Hz) slowed to {n} rpm by rotor resistance, delivering {M} kW.

::: part
answer: M/(1 - r)
unit: kW
tolerance: 0.5%

### Air-gap power?

::: misses
- [any] $P/(1 - s)$.
:::
:::

::: part
answer: M/(1 - r)*r
unit: kW
tolerance: 0.5%

### Rotor-circuit loss?

::: misses
- [any] $sP_\text{ag}$.
:::
:::
:::

::: check
kind: parts
given: T = 100 | 900; v = 0.8 | 0.9; k = 2 | 3.5

## A motor's breakdown torque is {k} times its {T} N·m rating at full voltage; the supply sags to {v}.

::: part
answer: k*T*v^2
unit: N·m
tolerance: 0.5%

### Breakdown torque during the sag?

::: misses
- [any] Scales as $V^2$.
:::
:::

::: part
answer: k*v^2
tolerance: 0.5%

### As a multiple of rated torque?

::: misses
- [any] $kv^2$.
:::
:::
:::

::: check
kind: parts
given: T = 300 | 450; v = 0.8 | 0.9; L = 100 | 150

## A motor with {T} N·m of breakdown torque at rated voltage carries a {L} N·m load when its supply sags to {v} of rated.

::: part
answer: T*v^2
unit: N·m
tolerance: 0.5%

### What breakdown torque does it have during the sag?

::: misses
- [T*v] Torque goes as voltage squared.
- [any] $v^2T_\max$.
:::
:::

::: part
answer: T*v^2/L
tolerance: 0.5%

### What margin over the load is left?

::: misses
- [any] Breakdown over load.
:::
:::
:::

::: check
kind: parts
given: k = 6 | 7; u = 1.5 | 3; I = 40 | 150

## A motor rated {I} A with locked-rotor current {k} times rated runs on a supply with {u}% true unbalance.

::: part
answer: k*u/100*I
unit: A
tolerance: 0.5%

### About what negative-sequence current does it draw?

::: misses
- [any] $(I_\text{lr}/I_\text{rated})u$ of rated.
:::
:::
:::

::: check
kind: parts
given: P = 1.5 | 3; n = 0.8 | 1.2

## A doubly fed generator sends {P} MW to the grid at {n} times synchronous speed (lossless).

::: part
answer: -(1 - n)*P/(2 - n)
unit: MW
tolerance: 0.5%

### What does its rotor converter deliver to the grid (negative if it draws)?

::: misses
- [any] $-sP_s$ with $P_s = P/(1 - s)$.
:::
:::
:::
:::