S12 Electric machines · Practice
Problem set 5: induction machine performance, tests, starting and speed control
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
An induction motor: phase voltage 230 V, = 0.1 Ω, = 0.9 Ω, = 30 Ω.
(a)
Thévenin voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Thévenin resistance?
Check
Thévenin source 150 V, = 0.1 Ω, = 1.6 Ω, = 0.25 Ω, = 125.7 rad/s.
(a)
Slip at breakdown?
(b)
Breakdown torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(c)
Starting torque?
Check
The same kind of motor (150 V, = 0.1, X = 1.6, = 0.25 Ω, = 125.7) at slip 0.02.
(a)
Torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Added rotor resistance for breakdown at standstill?
Check
Motor tests: DC 8 V at 15 A; no load at 400 V line, 20 A, with 400 W of rotational loss.
(a)
?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
No-load input power?
(c)
?
Check
Blocked rotor at 15 Hz: 27.73 V line, 25 A, 750 W; = 0.1 Ω (class B).
(a)
?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
at 60 Hz?
(c)
?
Check
A motor draws 5.5 times rated current and 1.4 times rated torque direct on line.
(a)
Wye–delta line current (× rated)?
(b)
Autotransformer at tap 0.8, line current?
(c)
Its starting torque?
Check
A rotor bar of resistivity 3.2 × 10⁻⁸ Ω·m on a 50 Hz supply.
(a)
Skin depth at standstill?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
At slip 0.01?
Check
An induction generator: 4 poles, 50 Hz, driven at 1545 rpm, = 30 Ω.
(a)
Slip?
(b)
Capacitance per phase to self-excite?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
A 400 V, 50 Hz, 6-pole motor on a constant-V/f drive at 35 Hz, needing 20 rpm of slip speed.
(a)
Drive voltage (no boost)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Speed?
Check
Base speed at 60 Hz: rated 150 N·m, breakdown 400 N·m. Field weakening at 110 Hz.
(a)
Torque at rated current?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Breakdown torque (ignoring resistance)?
Check
A wound-rotor motor (4 poles, 50 Hz) slowed to 900 rpm by rotor resistance, delivering 50 kW.
(a)
Air-gap power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
Rotor-circuit loss?
Check
A motor's breakdown torque is 3.5 times its 100 N·m rating at full voltage; the supply sags to 0.8.
(a)
Breakdown torque during the sag?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
As a multiple of rated torque?
Check
A motor with 300 N·m of breakdown torque at rated voltage carries a 150 N·m load when its supply sags to 0.8 of rated.
(a)
What breakdown torque does it have during the sag?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What margin over the load is left?
Check
A motor rated 150 A with locked-rotor current 6 times rated runs on a supply with 1.5% true unbalance.
(a)
About what negative-sequence current does it draw?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A doubly fed generator sends 1.5 MW to the grid at 0.8 times synchronous speed (lossless).
(a)
What does its rotor converter deliver to the grid (negative if it draws)?
Write units the way you normally would: 1.5 MW, 1500 kW and 0.0015 GW are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12