S12 Electric machines · Practice
Problem set 7: induction drives, generators and special machines
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A 4-pole, 50 Hz induction motor's Thévenin source is 220 V per phase behind 0.15 Ω, with 1.3 Ω of total leakage reactance and 0.25 Ω of rotor resistance; it runs at slip 0.02.
(a)
What torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What is its rotor copper loss?
Check
A motor rated 120 A with a locked-rotor current of 5.5 times rated runs on a supply with 2.5% voltage unbalance.
(a)
About how much negative-sequence current does it draw?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
By roughly how much does its temperature rise grow?
Check
A doubly fed generator delivers 2.5 MW to the grid at 0.75 times synchronous speed; neglect losses.
(a)
What does the stator carry?
Write units the way you normally would: 1.5 MW, 1500 kW and 0.0015 GW are the same answer.
(b)
How much power passes through the rotor converter?
Check
A drive of 2 kg·m² starts with 40 N·m against 30 N·m of load, to 1500 rpm.
(a)
How long does it take?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
How much energy must a regenerative stop recover?
Check
A motor of 0.0002 kg·m² must accelerate a 0.02 kg·m² load as fast as possible through a gearbox, with 5 N·m of motor torque.
(a)
What gear ratio?
(b)
What acceleration does the load then get?
Write units the way you normally would: 1.5 rad/s^2 and 1500 mrad/s^2 are the same answer.
Check
A 22 kW pump runs 7000 hours a year at 0.6 of full flow, with electricity at 0.2 dollars per kWh.
(a)
What does it draw under speed control?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
How much does that save per year against running at full speed?
Check
A series DC motor on 120 V with 0.2 Ω runs at 1400 rpm drawing 60 A; the load falls so that it draws 0.5 times as much current. Ignore saturation.
(a)
How fast does it now run?
(b)
By what factor has its torque changed?
Check
A PM motor rated 100 rpm/V on 12 V has 0.4 Ω of resistance and 2 A of no-load current.
(a)
What is its torque constant?
Write units the way you normally would: 1.5 N·m/A, 1500 mN·m/A and 0.0015 kN·m/A are the same answer.
(b)
What is its peak efficiency?
Check
A switched reluctance motor (3 phases, 4 rotor teeth) swings its inductance from 10 to 80 mH, at 8 A and 1500 rpm.
(a)
What average torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
How often is each phase switched on?
Check
A linear induction motor with a 0.2 m pole pitch on 30 Hz moves at 20 m/s with 500 kW crossing its gap.
(a)
What is its slip?
(b)
What thrust does it develop?
Write units the way you normally would: 1.5 kN, 1500 N and 0.0015 MN are the same answer.
Check
A voice coil with = 5 N/A and 2 Ω drives a 0.5 kg mass at 200 m/s².
(a)
What current does it need?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What does it dissipate?
Check
At standstill a single-phase motor's main winding is 3 + j\given4 Ω and its auxiliary 12 + j\given5 Ω, on 50 Hz.
(a)
What capacitor reactance puts their currents 90° apart?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
What capacitance?
Check
A wound-rotor motor (4 poles, 50 Hz) is slowed to 1500 rpm with rotor resistors, with 80 kW crossing its gap.
(a)
How much power do the resistors and rotor dissipate?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
How much mechanical power does it deliver?
Check
A motor that reaches speed in 2 s direct on line, with an average accelerating torque well above its load's, is started through an autotransformer on its 0.65 tap.
(a)
By what factor does its motor torque fall?
(b)
About how long does it now take to start, if the load torque is negligible?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
Check
A two-phase hybrid stepper with 50 rotor teeth is driven at 200 full steps per second with 32 microsteps per step.
(a)
At what speed does it turn?
(b)
What is its microstep angle?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12