S12 · Problem set 8
Problem set 8: the dq0 transformation, synchronous machine transients, field-oriented control, permanent-magnet motor control, and losses, heating and ratings
These problems cover lessons 39 to 47: dq currents, power and torque, the subtransient and transient reactances and the decaying fault current, rotor-flux orientation and its slip, MTPA and field weakening in PM machines, sensorless control, condition monitoring, and the thermal side of ratings.
Check
Balanced currents of 8 A peak lead the d axis by 20°; = 120 V, = 300 V.
(a)
?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
?
(c)
Power?
Check
A 4-pole surface PM machine, = 0.05 Wb, R = 0.1 Ω, = 80 A, = 0, at 600 rad/s electrical.
(a)
Torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Steady ?
Check
A machine: = 0.1, = 1.2, = 0.3, = 0.07 pu.
(a)
?
(b)
?
(c)
?
Check
A generator ( = 0.15, = 0.3, = 2 pu, = 0.03 s, = 1.6 s) is shorted from 1 pu.
(a)
Initial symmetrical current?
(b)
AC current at 0.05 s?
(c)
Largest DC offset (peak)?
Check
A 4-pole induction motor: = 40 mH, = 1.03 , = 0.4 Ω; rotor flux 1 Wb, = 20 A.
(a)
Rotor time constant?
Write units the way you normally would: 1.5 s and 1500 ms are the same answer.
(b)
?
(c)
Torque?
Check
The same kind of motor ( = 40 mH, = 1.03 , = 0.4 Ω, 4 poles, 1 Wb, = 20 A) at 900 rpm.
(a)
Slip frequency?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
Inverter frequency?
Check
An interior PM motor: 6 poles, = 0.06 Wb, = 0.25 mH, = 0.8 mH, 120 A.
(a)
MTPA ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Torque at MTPA?
(c)
Torque with all current on q?
Check
A 4-pole surface PM motor: = 0.06 Wb, L = 0.8 mH, 140 A, 120 V peak phase.
(a)
Base speed?
(b)
Characteristic current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A winding's resistance has risen to 1.2 times its 20 °C value; its insulation class is rated 180 °C.
(a)
Winding temperature?
(b)
Life relative to running at the class temperature?
Check
A duty cycle: 120 N·m for 4 s, 70 N·m for 50 s; a motor with 60 K steady rise and 20 min thermal time constant.
(a)
RMS torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
Rise after 15 min from cold?
Check
A 7.5 kW motor at 0.7 load for 7000 h a year; efficiency rises from 0.92 by 0.015; energy costs 0.1 dollars per kWh.
(a)
Energy saved?
Write units the way you normally would: 1.5 kWh, 1500 Wh and 0.0015 MWh are the same answer.
(b)
Dollars saved per year?
Check
Instantaneous phase currents 3, −4, −1.5 A; a rotor time constant of 1 s.
(a)
Zero-sequence current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Time for the flux to reach 0.9 of final?
Check
A drive's edges rise in 100 ns; its cable carries waves at 150 m/µs and is 80 m long.
(a)
What is the critical length?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
(b)
How long does a reflection take to return to the motor?
Check
An 8-pole interior PM motor ( = 0.06 Wb, = 0.15 mH, = 0.7 mH) runs at 250 A.
(a)
What gives maximum torque per ampere?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A generator with = 0.15 pu and armature time constant 0.08 s on 60 Hz is shorted at the worst instant.
(a)
How much DC offset remains half a cycle later, in per unit?
Check
A motor drive watches a 2-pole-pair machine.
(a)
At 1500 rpm, what electrical frequency must a sensorless observer track?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
On a 60 Hz supply at slip 0.04, where is the lower broken-bar sideband?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.