title: "Problem set 8: dq models, transients, drives and ratings"
heading: "Problem set 8: the dq0 transformation, synchronous machine transients, field-oriented control, permanent-magnet motor control, and losses, heating and ratings"
eyebrow: S12 · Problem set 8
type: problems
---

::: hook
These problems cover lessons 39 to 47: dq currents, power and torque, the subtransient and transient reactances and the decaying fault current, rotor-flux orientation and its slip, MTPA and field weakening in PM machines, sensorless control, condition monitoring, and the thermal side of ratings.
:::

::: pool
pick: 12

::: check
kind: parts
given: I = 8 | 30; p = 20 | 50; v = 100 | 300; u = 20 | 120

## Balanced currents of {I} A peak lead the d axis by {p}°; $v_d$ = {u} V, $v_q$ = {v} V.

::: part
answer: I*cos(p*pi/180)
unit: A
tolerance: 0.5%

### $i_d$?

::: misses
- [any] $I\cos\phi$.
:::
:::

::: part
answer: I*sin(p*pi/180)
unit: A
tolerance: 0.5%

### $i_q$?

::: misses
- [any] $I\sin\phi$.
:::
:::

::: part
answer: 1.5*(u*I*cos(p*pi/180) + v*I*sin(p*pi/180))
unit: W
tolerance: 0.5%

### Power?

::: misses
- [any] $\frac{3}{2}(v_di_d + v_qi_q)$.
:::
:::
:::

::: check
kind: parts
given: P = 4 | 8; l = 0.05 | 0.15; q = 20 | 80; R = 0.02 | 0.1; w = 600 | 1800

## A {P}-pole surface PM machine, $\lambda_m$ = {l} Wb, R = {R} Ω, $i_q$ = {q} A, $i_d$ = 0, at {w} rad/s electrical.

::: part
answer: 1.5*P/2*l*q
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] $\frac{3}{2}\frac{P}{2}\lambda_mi_q$.
:::
:::

::: part
answer: R*q + w*l
unit: V
tolerance: 0.5%

### Steady $v_q$?

::: misses
- [any] $Ri_q + \omega\lambda_m$.
:::
:::
:::

::: check
kind: parts
given: l = 0.1 | 0.18; a = 1.2 | 2; f = 0.12 | 0.3; k = 0.03 | 0.07

## A machine: $X_l$ = {l}, $X_{ad}$ = {a}, $X_{fl}$ = {f}, $X_{kdl}$ = {k} pu.

::: part
answer: l + a
tolerance: 0.5%

### $X_d$?

::: misses
- [any] $X_l + X_{ad}$.
:::
:::

::: part
answer: l + a*f/(a + f)
tolerance: 0.5%

### $X'_d$?

::: misses
- [any] $X_l + X_{ad} \parallel X_{fl}$.
:::
:::

::: part
answer: l + 1/(1/a + 1/f + 1/k)
tolerance: 0.5%

### $X''_d$?

::: misses
- [any] All three in parallel, plus $X_l$.
:::
:::
:::

::: check
kind: parts
given: x = 0.15 | 0.25; y = 0.3 | 0.4; X = 1.2 | 2; T = 0.8 | 1.6; t = 0.05 | 0.15

## A generator ($X''_d$ = {x}, $X'_d$ = {y}, $X_d$ = {X} pu, $T''_d$ = 0.03 s, $T'_d$ = {T} s) is shorted from 1 pu.

::: part
answer: 1/x
tolerance: 0.5%

### Initial symmetrical current?

::: misses
- [any] $1/X''_d$.
:::
:::

::: part
answer: 1/X + (1/y - 1/X)*exp(-t/T) + (1/x - 1/y)*exp(-t/0.03)
tolerance: 0.5%

### AC current at {t} s?

::: misses
- [any] Three levels, two decays.
:::
:::

::: part
answer: sqrt(2)/x
tolerance: 0.5%

### Largest DC offset (peak)?

::: misses
- [any] $\sqrt{2}/X''_d$.
:::
:::
:::

::: check
kind: parts
given: M = 40 | 120; k = 1.03 | 1.06; R = 0.1 | 0.4; l = 0.5 | 1; q = 20 | 80; P = 4 | 6

## A {P}-pole induction motor: $L_m$ = {M} mH, $L_r$ = {k} $L_m$, $R_r$ = {R} Ω; rotor flux {l} Wb, $i_{qs}$ = {q} A.

::: part
answer: k*M*1e-3/R
unit: s
tolerance: 0.5%

### Rotor time constant?

::: misses
- [any] $L_r/R_r$.
:::
:::

::: part
answer: l/(M*1e-3)
unit: A
tolerance: 0.5%

### $i_{ds}$?

::: misses
- [any] $\lambda_r/L_m$.
:::
:::

::: part
answer: 1.5*P/2/k*l*q
unit: N·m
tolerance: 0.5%

### Torque?

::: misses
- [any] $\frac{3}{2}\frac{P}{2}\frac{L_m}{L_r}\lambda_ri_{qs}$.
:::
:::
:::

::: check
kind: parts
given: M = 40 | 120; k = 1.03 | 1.06; R = 0.1 | 0.4; l = 0.5 | 1; q = 20 | 80; n = 900 | 1700; P = 4 | 6

## The same kind of motor ($L_m$ = {M} mH, $L_r$ = {k} $L_m$, $R_r$ = {R} Ω, {P} poles, {l} Wb, $i_{qs}$ = {q} A) at {n} rpm.

::: part
answer: M*1e-3*q/(k*M*1e-3/R*l)
unit: rad/s
tolerance: 0.5%

### Slip frequency?

::: misses
- [any] $L_mi_{qs}/(\tau_r\lambda_r)$.
:::
:::

::: part
answer: (n*2*pi/60*P/2 + M*1e-3*q/(k*M*1e-3/R*l))/(2*pi)
unit: Hz
tolerance: 0.5%

### Inverter frequency?

::: misses
- [any] $(\omega_r + \omega_\text{sl})/2\pi$.
:::
:::
:::

::: check
kind: parts
given: P = 6 | 8; l = 0.06 | 0.1; a = 0.15 | 0.25; b = 0.5 | 0.8; I = 120 | 250

## An interior PM motor: {P} poles, $\lambda_m$ = {l} Wb, $L_d$ = {a} mH, $L_q$ = {b} mH, {I} A.

::: part
answer: (l - sqrt(l^2 + 8*((b - a)*1e-3)^2*I^2))/(4*(b - a)*1e-3)
unit: A
tolerance: 0.5%

### MTPA $i_d$?

::: misses
- [any] The MTPA formula.
:::
:::

::: part
answer: 1.5*P/2*(l*sqrt(I^2 - ((l - sqrt(l^2 + 8*((b - a)*1e-3)^2*I^2))/(4*(b - a)*1e-3))^2) + (a - b)*1e-3*(l - sqrt(l^2 + 8*((b - a)*1e-3)^2*I^2))/(4*(b - a)*1e-3)*sqrt(I^2 - ((l - sqrt(l^2 + 8*((b - a)*1e-3)^2*I^2))/(4*(b - a)*1e-3))^2))
unit: N·m
tolerance: 0.5%

### Torque at MTPA?

::: misses
- [any] Magnet plus reluctance at the MTPA currents.
:::
:::

::: part
answer: 1.5*P/2*l*I
unit: N·m
tolerance: 0.5%

### Torque with all current on q?

::: misses
- [any] Magnet torque only.
:::
:::
:::

::: check
kind: parts
given: V = 120 | 300; l = 0.06 | 0.12; L = 0.3 | 0.8; i = 60 | 140; P = 4 | 8

## A {P}-pole surface PM motor: $\lambda_m$ = {l} Wb, L = {L} mH, {i} A, {V} V peak phase.

::: part
answer: V/sqrt((L*1e-3*i)^2 + l^2)/(P/2)*60/(2*pi)
unit: rpm
tolerance: 0.5%

### Base speed?

::: misses
- [any] Voltage limit with $i_d$ = 0.
:::
:::

::: part
answer: l/(L*1e-3)
unit: A
tolerance: 0.5%

### Characteristic current?

::: misses
- [any] $\lambda_m/L$.
:::
:::
:::

::: check
kind: parts
given: r = 1.2 | 1.4; T = 20 | 25; c = 155 | 180

## A winding's resistance has risen to {r} times its {T} °C value; its insulation class is rated {c} °C.

::: part
answer: r*(234.5 + T) - 234.5
unit: °C
tolerance: 0.5%

### Winding temperature?

::: misses
- [any] $r(234.5 + T) - 234.5$.
:::
:::

::: part
answer: 2^((c - (r*(234.5 + T) - 234.5))/10)
tolerance: 0.5%

### Life relative to running at the class temperature?

::: misses
- [any] $2^{(T_\text{class} - T)/10}$.
:::
:::
:::

::: check
kind: parts
given: a = 120 | 250; t = 4 | 10; b = 30 | 70; u = 20 | 50; d = 60 | 90; m = 20 | 45

## A duty cycle: {a} N·m for {t} s, {b} N·m for {u} s; a motor with {d} K steady rise and {m} min thermal time constant.

::: part
answer: sqrt((a^2*t + b^2*u)/(t + u))
unit: N·m
tolerance: 0.5%

### RMS torque?

::: misses
- [any] $\sqrt{\sum T^2t/\sum t}$.
:::
:::

::: part
answer: d*(1 - exp(-15/m))
unit: K
tolerance: 0.5%

### Rise after 15 min from cold?

::: misses
- [any] $\Delta T(1 - e^{-t/\tau})$.
:::
:::
:::

::: check
kind: parts
given: P = 7.5 | 45; x = 0.7 | 0.9; h = 3000 | 7000; e = 0.89 | 0.92; f = 0.015 | 0.03; c = 0.1 | 0.2

## A {P} kW motor at {x} load for {h} h a year; efficiency rises from {e} by {f}; energy costs {c} dollars per kWh.

::: part
answer: P*x*h*(1/e - 1/(e + f))
unit: kWh
tolerance: 0.5%

### Energy saved?

::: misses
- [any] Output energy × $(1/\eta_1 - 1/\eta_2)$.
:::
:::

::: part
answer: P*x*h*(1/e - 1/(e + f))*c
tolerance: 0.5%

### Dollars saved per year?

::: misses
- [any] Energy × price.
:::
:::
:::

::: check
kind: parts
given: a = 3 | 9; b = -4 | 2; c = -6.5 | -1.5; t = 0.2 | 1; p = 0.9 | 0.95

## Instantaneous phase currents {a}, {b}, {c} A; a rotor time constant of {t} s.

::: part
answer: (a + b + c)/3
unit: A
tolerance: 0.5%

### Zero-sequence current?

::: misses
- [any] The average.
:::
:::

::: part
answer: -t*ln(1 - p)
unit: s
tolerance: 0.5%

### Time for the flux to reach {p} of final?

::: misses
- [any] $-\tau\ln(1 - p)$.
:::
:::
:::

::: check
kind: parts
given: t = 40 | 100 | 250; v = 150 | 190; l = 5 | 25 | 80

## A drive's edges rise in {t} ns; its cable carries waves at {v} m/µs and is {l} m long.

::: part
answer: v*t*1e-3/2
unit: m
tolerance: 0.5%

### What is the critical length?

::: misses
- [any] $vt_r/2$.
:::
:::

::: part
answer: 2*l/(v*1e6)*1e6
unit: µs
tolerance: 0.5%

### How long does a reflection take to return to the motor?

::: misses
- [any] The round trip, $2l/v$.
:::
:::
:::

::: check
kind: parts
given: m = 0.06 | 0.1; x = 0.15 | 0.25; y = 0.5 | 0.7; I = 120 | 250

## An 8-pole interior PM motor ($\lambda_m$ = {m} Wb, $L_d$ = {x} mH, $L_q$ = {y} mH) runs at {I} A.

::: part
answer: (m - sqrt(m^2 + 8*((y - x)*1e-3)^2*I^2))/(4*(y - x)*1e-3)
unit: A
tolerance: 0.5%

### What $i_d$ gives maximum torque per ampere?

::: misses
- [any] The MTPA formula.
:::
:::
:::

::: check
kind: parts
given: s = 0.15 | 0.22; T = 0.08 | 0.2; f = 50 | 60

## A generator with $X''_d$ = {s} pu and armature time constant {T} s on {f} Hz is shorted at the worst instant.

::: part
answer: sqrt(2)/s*exp(-1/(2*f*T))
tolerance: 0.5%

### How much DC offset remains half a cycle later, in per unit?

::: misses
- [any] $(\sqrt2/X''_d)e^{-t/T_a}$.
:::
:::
:::

::: check
kind: parts
given: n = 1500 | 3600; p = 2 | 4; f = 50 | 60; s = 0.02 | 0.04

## A motor drive watches a {p}-pole-pair machine.

::: part
answer: n*p/60
unit: Hz
tolerance: 0.5%

### At {n} rpm, what electrical frequency must a sensorless observer track?

::: misses
- [n/60] Multiply by the pole pairs.
- [any] Not yet. $np/60$.
:::
:::

::: part
answer: f*(1 - 2*s)
unit: Hz
tolerance: 0.5%

### On a {f} Hz supply at slip {s}, where is the lower broken-bar sideband?

::: misses
- [f*(1 - s)] It's at $2s$ from the supply.
- [any] Not yet. $(1 - 2s)f$.
:::
:::

::: right
Right. Both diagnostics are frequencies set by the machine's speed and poles.
:::
:::
:::