S12 · Problem set 9
Problem set 9: dq0 quantities, synchronous machine transients and fault currents, field-oriented and PM motor control, reflected waves and bearing voltages, heating, ratings and efficiency
These problems cover lessons 39 to 48: machines in the rotating frame, in transients and under control, and the practical effects of feeding them from inverters. As in a drive's commissioning, the numbers come from nameplates and test data, and several problems end with a decision: whether the motor will overheat, whether the insulation will survive, whether the drive can reach the speed.
Check
At one instant = 8 A and = −3 A in a three-wire machine, with the rotor's d axis at θ = 60°.
(a)
What is ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is ?
Check
A controller commands = 0 A and = 10 A with the rotor at θ = 110°.
(a)
What is ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is ?
Check
A machine's d axis has = 0.15, = 1.2, = 0.25 and = 0.08 pu.
(a)
What is ?
(b)
What is ?
Check
A generator shorted from 1 pu has = 1.5, = 0.25, = 0.22 pu, = 1.6 s and = 0.03 s.
(a)
What is its symmetrical current 0.05 s after the fault, in per unit?
(b)
What does it settle to?
Check
A generator ( = 0.2 pu, armature time constant 0.1 s, on 60 Hz) is shorted at the instant that gives the largest offset. Treat the AC component as still at its subtransient value half a cycle later.
(a)
What is the initial DC offset, in per unit?
(b)
Roughly how high is the first peak?
Check
A 4-pole induction motor ( = 1.03, = 0.15 Ω) runs under field orientation at 1 Wb rotor flux with = 60 A.
(a)
What torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What slip frequency must the drive impose?
Check
A field-oriented drive makes 200 N·m at base speed with 0.6 Wb of rotor flux, then runs at 1.5 times base speed with its flux weakened in proportion and the same .
(a)
What rotor flux does it use?
Write units the way you normally would: 1.5 Wb, 1500 mWb and 0.0015 kWb are the same answer.
(b)
What torque does it make?
Check
A 6-pole interior PM motor ( = 0.05 Wb, = 0.1 mH, = 0.7 mH) runs under MTPA at 200 A.
(a)
What is ?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What torque does it make?
Check
A 4-pole surface PM motor ( = 0.06 Wb, L = 0.4 mH) is rated 120 A on a drive limited to 350 V peak per phase.
(a)
What is its base speed?
(b)
What is its characteristic current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A drive's 800 V edges rise in 60 ns on a cable carrying waves at 140 m/µs to a motor that reflects with Γ = 0.95.
(a)
What is the critical cable length?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
(b)
What peak reaches the motor on a cable much longer than that?
Check
A two-level drive on 650 V feeds a motor with a 2% bearing voltage ratio; its bearings' film breaks down at about 15 V.
(a)
How large are the bearing voltage steps?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is their ratio to the breakdown voltage?
Check
A winding's resistance rises by a factor of 1.2 from its value at 20 °C, and its hot spot runs 15 K above the average; its insulation is rated 180 °C.
(a)
How hot is the hot spot?
(b)
What relative life does that give the insulation?
Check
A motor's cycle repeats: 30 N·m for 5 s, 20 N·m for 40 s, 0 N·m for 10 s.
(a)
What RMS torque must it be rated for?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 30 kW motor runs at 0.6 of rated output for 8000 hours a year. Replacing its 0.91-efficient model with a 0.92-efficient one costs extra; electricity is 0.1 dollars per kWh.
(a)
How much energy does the better motor save per year?
Write units the way you normally would: 1.5 kWh, 1500 Wh and 0.0015 MWh are the same answer.
(b)
What is that worth?
Check
A PM motor ( = 0.05 Wb, = 0.2 mH, = 0.9 mH, R = 0.08 Ω) runs steadily at 800 rad/s electrical with = −40 A and = 60 A.
(a)
What is ?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is ?
(c)
What peak phase voltage must the inverter supply?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.