S1249 of 55
0 XP
  1. Hook
  2. Problems

S12 · Problem set 9

Problem set 9: dq0 quantities, synchronous machine transients and fault currents, field-oriented and PM motor control, reflected waves and bearing voltages, heating, ratings and efficiency

These problems cover lessons 39 to 48: machines in the rotating frame, in transients and under control, and the practical effects of feeding them from inverters. As in a drive's commissioning, the numbers come from nameplates and test data, and several problems end with a decision: whether the motor will overheat, whether the insulation will survive, whether the drive can reach the speed.

Check

At one instant ia = 8 A and ib = −3 A in a three-wire machine, with the rotor's d axis at θ = 60°.

(a)

What is id?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What is iq?

Check

A controller commands id = 0 A and iq = 10 A with the rotor at θ = 110°.

(a)

What is ia?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What is ib?

Check

A machine's d axis has Xl = 0.15, Xad = 1.2, Xfl = 0.25 and Xkdl = 0.08 pu.

(a)

What is X′d?

(b)

What is X′′d?

Check

A generator shorted from 1 pu has Xd = 1.5, X′d = 0.25, X′′d = 0.22 pu, T′d = 1.6 s and T′′d = 0.03 s.

(a)

What is its symmetrical current 0.05 s after the fault, in per unit?

(b)

What does it settle to?

Check

A generator (X′′d = 0.2 pu, armature time constant 0.1 s, on 60 Hz) is shorted at the instant that gives the largest offset. Treat the AC component as still at its subtransient value half a cycle later.

(a)

What is the initial DC offset, in per unit?

(b)

Roughly how high is the first peak?

Check

A 4-pole induction motor (Lr = 1.03Lm, Rr = 0.15 Ω) runs under field orientation at 1 Wb rotor flux with iqs = 60 A.

(a)

What torque does it make?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

(b)

What slip frequency must the drive impose?

Check

A field-oriented drive makes 200 N·m at base speed with 0.6 Wb of rotor flux, then runs at 1.5 times base speed with its flux weakened in proportion and the same iqs.

(a)

What rotor flux does it use?

Write units the way you normally would: 1.5 Wb, 1500 mWb and 0.0015 kWb are the same answer.

(b)

What torque does it make?

Check

A 6-pole interior PM motor (λm = 0.05 Wb, Ld = 0.1 mH, Lq = 0.7 mH) runs under MTPA at 200 A.

(a)

What is id?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What torque does it make?

Check

A 4-pole surface PM motor (λm = 0.06 Wb, L = 0.4 mH) is rated 120 A on a drive limited to 350 V peak per phase.

(a)

What is its base speed?

(b)

What is its characteristic current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A drive's 800 V edges rise in 60 ns on a cable carrying waves at 140 m/µs to a motor that reflects with Γ = 0.95.

(a)

What is the critical cable length?

Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.

(b)

What peak reaches the motor on a cable much longer than that?

Check

A two-level drive on 650 V feeds a motor with a 2% bearing voltage ratio; its bearings' film breaks down at about 15 V.

(a)

How large are the bearing voltage steps?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(b)

What is their ratio to the breakdown voltage?

Check

A winding's resistance rises by a factor of 1.2 from its value at 20 °C, and its hot spot runs 15 K above the average; its insulation is rated 180 °C.

(a)

How hot is the hot spot?

(b)

What relative life does that give the insulation?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.