S1217 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S12 · Lesson 17 · Salient-pole machines

Why a rotor with projecting poles has different reactances along and across its poles, two-reaction theory with the direct- and quadrature-axis reactances, finding the excitation voltage, the power-angle curve with its reluctance term, and measuring the two reactances with the slip test

Hydro generators turn slowly, so they need many poles, and many poles are easiest to build as separate pole pieces bolted to a hub, with wide air spaces between them. Flux crosses the gap easily along a pole and poorly between poles, so the armature's reaction depends on where its MMF points relative to the rotor. A single synchronous reactance can't describe that. Splitting the armature current into a part along the poles and a part between them, each with its own reactance, can.

  • The power-angle curve of a salient-pole machine on a 1 pu bus: the field term VEfXdsin⁡δ, the reluctance term V2(Xd−Xq)2XdXqsin⁡2δ, and their sum.
  • The reluctance term exists even with no field current at all; it pulls the peak to an angle below 90° and raises it.
  • With Xq=Xd the machine is cylindrical and the curve is a pure sine.

Predict

A salient-pole machine has Xd = 1.0 pu and Xq = 0.6 pu. With its field switched off, can it still produce torque on a 1 pu bus?

Name it

Two axes

The direct axis (d) lies along the rotor's poles; the quadrature axis (q) is 90° electrical ahead, between them. Split the armature current into Id along d and Iq along q. Each produces armature reaction through its own path, so each has its own reactance: Xd (large, low-reluctance path) and Xq (smaller).

The phasor equation

For a generator, with Ra neglected:

E^f=V^+jXdI^d+jXqI^q

Ef lies on the q axis. To find δ, first compute E^′=V^+jXqI^, which points along Ef. Then Id=Isin⁡(δ+ϕ) (with φ the power factor angle, lagging positive), and

Ef=|E′|+(Xd−Xq)Id

Power

P=VEfXdsin⁡δ+V2(Xd−Xq)2XdXqsin⁡2δ

The second, reluctance term peaks at 45°. Together they peak below 90°, where cos⁡δ=−a+a2+32b28b with a and b the two coefficients.

The slip test

Drive the unexcited rotor slightly off synchronous speed with reduced voltage on the armature. As the rotor slips past the stator field, the impedance swings between Xd (largest voltage, smallest current) and Xq: Xd=Vmax/Imin and Xq=Vmin/Imax per phase.

Worked example

A salient-pole generator (Xd = 1.0, Xq = 0.6 pu) delivers 1 pu current at 0.8 power factor lagging on a 1 pu bus. Find Ef and δ.

Show the solution
  1. Current. I = 0.8 − j0.6.
  2. Voltage behind Xq. E′=1+j0.6(0.8−j0.6)=1.36+j0.48 so |E'| = 1.442 at δ = 19.44°.
  3. Direct-axis current. The current lags Ef by 36.87° + 19.44° = 56.31°, so Id=sin⁡56.31°=0.832
  4. Excitation voltage. Ef=1.442+0.4×0.832=1.775pu
  5. Check. The power comes back to 0.8 pu: P=1.775sin⁡19.44°+0.333sin⁡38.88°=0.591+0.209=0.800pu

Answer Ef = 1.775 pu at δ = 19.44°.

Worked example

At that excitation, what's the generator's maximum power, and where?

Show the solution
  1. Angle of maximum power. With a = 1.775 and b = 0.333, cos⁡δ=−a+a2+32b28b=0.305 so δ = 72.2°.
  2. Maximum power. Pmax = 1.884 pu.
  3. Compare with a round rotor. A round-rotor machine with Xs=Xd and the same Ef would peak at 1.775 pu at 90°: saliency adds 6% and makes the machine stiffer at small angles.

Answer the maximum power is 1.884 pu, at δ = 72.2°.

Worked example

A slip test on a 50 kVA, 480 V, Y-connected salient-pole machine reads 120 V and 40 A per phase at the voltage maximum, and 110 V and 60 A at the current maximum. Find Xd and Xq, and the power it can carry if its field fails.

Show the solution
  1. Direct-axis reactance. Xd=Vmax⁡Imin⁡=12040=3.0Ω
  2. Quadrature-axis reactance. Xq=Vmin⁡Imax⁡=11060=1.83Ω
  3. In per unit. The base impedance is Zb=480250000=4.61Ω so they're 0.651 and 0.398 pu.
  4. Power with no field. Only the reluctance term remains, peaking at 45°: P=V2(Xd−Xq)2XdXq=0.2532×0.651×0.398=0.49pu
  5. Running on reluctance torque. A salient-pole motor that loses its excitation can keep running at light load on reluctance torque alone, though it draws a large lagging current.

Answer Xd = 3.0 Ω (0.651 pu) and Xq = 1.83 Ω (0.398 pu), and with its field failed it can still carry 0.49 pu.

Check

A salient-pole machine with Xd = 0.9 pu and Xq = 0.7 pu sits on a 1 pu bus with no field current. What's its largest reluctance power?

Check

A salient-pole machine (Xd = 0.9, Xq = 0.7 pu, Ef = 1.2 pu, 1 pu bus) runs at δ = 50°. What power does it deliver?

Check

A salient-pole generator (Xd = 0.9, Xq = 0.5 pu) delivers 1 pu at power factor 0.9 lagging on a 1 pu bus. What's its load angle?

Check

The same generator (Xd = 0.9, Xq = 0.5 pu, 1 pu at power factor 0.9 lagging). What's Ef?

Check

In a slip test the phase voltage swings between 10 V and 20 V while the current swings between 12 A and 16 A. What's Xq?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

At what load angle does a salient-pole machine (Xd = 0.9, Xq = 0.7 pu, Ef = 1.2 pu, 1 pu bus) reach its maximum power?

Check

A salient-pole generator (Xd = 0.9, Xq = 0.5 pu) delivers 1 pu current at power factor 0.9 lagging to a 1 pu bus.

(a)

What is its load angle?

(b)

What is its excitation voltage, in per unit?

Check

A salient-pole machine (Xd = x, Xq = y) on a 1 pu bus has excitation E and load angle d degrees.

Step 1

What is its excitation power term?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why is the direct-axis reactance of a salient-pole machine larger than the quadrature-axis one?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.