S12 · Lesson 17 · Salient-pole machines
Why a rotor with projecting poles has different reactances along and across its poles, two-reaction theory with the direct- and quadrature-axis reactances, finding the excitation voltage, the power-angle curve with its reluctance term, and measuring the two reactances with the slip test
Hydro generators turn slowly, so they need many poles, and many poles are easiest to build as separate pole pieces bolted to a hub, with wide air spaces between them. Flux crosses the gap easily along a pole and poorly between poles, so the armature's reaction depends on where its MMF points relative to the rotor. A single synchronous reactance can't describe that. Splitting the armature current into a part along the poles and a part between them, each with its own reactance, can.
- The power-angle curve of a salient-pole machine on a 1 pu bus: the field term , the reluctance term , and their sum.
- The reluctance term exists even with no field current at all; it pulls the peak to an angle below 90° and raises it.
- With the machine is cylindrical and the curve is a pure sine.
Predict
A salient-pole machine has = 1.0 pu and = 0.6 pu. With its field switched off, can it still produce torque on a 1 pu bus?
The rotor's poles are easier paths for flux than the spaces between them, so the stator field pulls them into line, like the reluctance torque of lesson 4. The power is , peaking at 0.4/1.2 = 0.333 pu at 45°. Reluctance motors run on this alone.
Name it
Two axes
The direct axis (d) lies along the rotor's poles; the quadrature axis (q) is 90° electrical ahead, between them. Split the armature current into along d and along q. Each produces armature reaction through its own path, so each has its own reactance: (large, low-reluctance path) and (smaller).
The phasor equation
For a generator, with neglected:
lies on the q axis. To find δ, first compute , which points along . Then (with φ the power factor angle, lagging positive), and
Power
The second, reluctance term peaks at 45°. Together they peak below 90°, where with a and b the two coefficients.
The slip test
Drive the unexcited rotor slightly off synchronous speed with reduced voltage on the armature. As the rotor slips past the stator field, the impedance swings between (largest voltage, smallest current) and : and per phase.
Worked example
A salient-pole generator ( = 1.0, = 0.6 pu) delivers 1 pu current at 0.8 power factor lagging on a 1 pu bus. Find and δ.
Show the solution
- Current. I = 0.8 − j0.6.
- Voltage behind . so |E'| = 1.442 at δ = 19.44°.
- Direct-axis current. The current lags by 36.87° + 19.44° = 56.31°, so
- Excitation voltage.
- Check. The power comes back to 0.8 pu:
Answer = 1.775 pu at δ = 19.44°.
Worked example
At that excitation, what's the generator's maximum power, and where?
Show the solution
- Angle of maximum power. With a = 1.775 and b = 0.333, so δ = 72.2°.
- Maximum power. = 1.884 pu.
- Compare with a round rotor. A round-rotor machine with and the same would peak at 1.775 pu at 90°: saliency adds 6% and makes the machine stiffer at small angles.
Answer the maximum power is 1.884 pu, at δ = 72.2°.
Worked example
A slip test on a 50 kVA, 480 V, Y-connected salient-pole machine reads 120 V and 40 A per phase at the voltage maximum, and 110 V and 60 A at the current maximum. Find and , and the power it can carry if its field fails.
Show the solution
- Direct-axis reactance.
- Quadrature-axis reactance.
- In per unit. The base impedance is so they're 0.651 and 0.398 pu.
- Power with no field. Only the reluctance term remains, peaking at 45°:
- Running on reluctance torque. A salient-pole motor that loses its excitation can keep running at light load on reluctance torque alone, though it draws a large lagging current.
Answer = 3.0 Ω (0.651 pu) and = 1.83 Ω (0.398 pu), and with its field failed it can still carry 0.49 pu.
Check
A salient-pole machine with = 0.9 pu and = 0.7 pu sits on a 1 pu bus with no field current. What's its largest reluctance power?
Check
A salient-pole machine ( = 0.9, = 0.7 pu, = 1.2 pu, 1 pu bus) runs at δ = 50°. What power does it deliver?
Check
A salient-pole generator ( = 0.9, = 0.5 pu) delivers 1 pu at power factor 0.9 lagging on a 1 pu bus. What's its load angle?
Check
The same generator ( = 0.9, = 0.5 pu, 1 pu at power factor 0.9 lagging). What's ?
Check
In a slip test the phase voltage swings between 10 V and 20 V while the current swings between 12 A and 16 A. What's ?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
At what load angle does a salient-pole machine ( = 0.9, = 0.7 pu, = 1.2 pu, 1 pu bus) reach its maximum power?
Check
A salient-pole generator ( = 0.9, = 0.5 pu) delivers 1 pu current at power factor 0.9 lagging to a 1 pu bus.
(a)
What is its load angle?
(b)
What is its excitation voltage, in per unit?
Check
A salient-pole machine ( = x, = y) on a 1 pu bus has excitation E and load angle d degrees.
Step 1
What is its excitation power term?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is its reluctance power term?
Explain why
Why is the direct-axis reactance of a salient-pole machine larger than the quadrature-axis one?
Each reactance measures how much flux, and hence how much voltage, a given armature current sets up. Armature MMF along the direct axis drives flux straight into the rotor's poles across a short air gap, an easy path with low reluctance, so it produces a lot of flux per ampere: a large reactance. MMF along the quadrature axis drives flux into the wide spaces between the poles, a path that's mostly air, so it produces much less flux per ampere: a smaller reactance. In a round-rotor machine the gap is the same everywhere and the two are nearly equal.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.