S12 · Lesson 35 · Single-phase induction motors
Why a single-phase winding produces no starting torque, the double revolving-field model with its forward and backward halves, torque as the difference between them, split-phase, capacitor-start and permanent-split-capacitor motors, and choosing the capacitor for a 90° split
Most homes have only single-phase power, yet refrigerators, washing machines and furnace blowers all run on induction motors. A single winding makes only a pulsating field, which lesson 8 split into two equal fields rotating in opposite directions. At standstill they pull equally both ways and the rotor stays put. Once it's turning, though, the forward field wins. Every single-phase motor is a scheme for getting it started.
- Torque against speed for a single-phase induction motor: the forward field's torque, the backward field's (negative), and their sum, using the double revolving-field circuit.
- At standstill the two cancel exactly: no starting torque. Spun either way, the motor accelerates in that direction.
- The net torque falls to zero slightly below synchronous speed, at a larger slip than a three-phase motor's, because the backward field always drags.
Predict
A single-phase induction motor is connected at standstill with its auxiliary winding open. What happens?
The pulsating field is two equal rotating fields, and at standstill they produce equal and opposite torques, so the motor draws a large current and hums. Once the rotor turns, the field it moves with sees a small slip and makes much more torque than the one it moves against, so it accelerates in whatever direction it was pushed.
Name it
Two revolving fields
The main winding's pulsating MMF is two fields of half amplitude rotating at . A rotor at slip s relative to the forward field has slip relative to the backward one. The equivalent circuit puts two half-circuits in series with the stator:
Torque and power
With main-winding current I, the forward and backward air-gap powers are and (the real parts of and ), and
At s = 1, and the torque is zero.
Starting
An auxiliary winding 90° away in space, carrying a current out of phase with the main winding's, makes the field partly rotate.
- Split-phase: a high-resistance auxiliary winding; modest phase shift, switched out by a centrifugal switch near 75% speed.
- Capacitor-start: a capacitor in the auxiliary winding brings its current near 90° ahead: high starting torque.
- Permanent split capacitor: a smaller capacitor left in, for smoother, quieter running (fans).
For a 90° split at standstill between a main winding and an auxiliary , the capacitor's reactance must be .
Worked example
A 120 V, 4-pole, 60 Hz motor: = 2.0, = 2.5, = 60, = 4.0, = 2.0 Ω, at s = 0.05. Find its current, torque and output.
Show the solution
- Forward and backward impedances. = 14.06 + j19.11 Ω and = 0.96 + j1.00 Ω, so the total impedance is 17.02 + j22.61 Ω.
- Current and input. I = 4.24 A at 0.60 power factor, an input of 306 W.
- Air-gap powers. The forward field takes 252.8 W and the backward 17.3 W.
- Torque.
- Output. which is 0.30 hp.
Answer it draws 4.24 A at 0.60 power factor and makes 1.25 N·m, an output of 224 W (0.30 hp).
Worked example
At standstill the main winding is 4 + j6 Ω and the auxiliary 9 + j3 Ω. What capacitor puts their currents 90° apart on 60 Hz?
Show the solution
- Capacitor reactance.
- Capacitance.
- Check. The auxiliary branch is then 9 − j6 Ω, at −33.7°, exactly 90° ahead of the main winding's +56.3°.
Answer a 295 µF capacitor.
Worked example
Where do the 120 V motor's 306 W of input go at s = 0.05?
Show the solution
- Stator copper.
- Across the gap. The forward field takes 252.8 W and the backward field 17.3 W.
- Rotor losses. The rotor loses of the forward power, 12.6 W, but of the backward, 33.7 W, because the rotor slips nearly twice synchronous speed against the backward field.
- Mechanical power. What's left is mechanical:
- Cost of the backward field. It costs almost three times the rotor loss of the forward one while subtracting torque, which is why single-phase motors are larger and less efficient than three-phase motors of the same rating.
Answer 36.0 W goes to stator copper, 12.6 W and 33.7 W to rotor loss from the forward and backward fields, and 223.8 W to mechanical power.
Check
A single-phase motor runs at slip 0.05 relative to its forward field. What's its slip relative to the backward field?
Check
At standstill a main winding is 4 + j\given8 Ω and an auxiliary winding 2 + j\given5 Ω. What series capacitor reactance in the auxiliary winding makes their currents 90° apart?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What capacitance has 9 Ω of reactance at 50 Hz?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
A 4-pole, 50 Hz single-phase motor draws 4.5 A, with = 8 Ω and = 1.2 Ω. What torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A single-phase motor at slip 0.06 draws 4.5 A with = 8 Ω and = 1.2 Ω. What's its mechanical power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
For the same motor (slip 0.06, 4.5 A, = 8 Ω, = 1.2 Ω), what's the rotor copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A 4-pole, 60 Hz single-phase motor runs at slip 0.03 with 5 A in its main winding; the real parts of its forward and backward impedances are 12 and 1.2 Ω.
(a)
What torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What is its rotor copper loss?
Check
At standstill a motor's main winding is R + jX and its auxiliary winding a + jx, on f hertz.
Step 1
What capacitor reactance puts their currents 90° apart?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What capacitance?
Explain why
Why does a single-phase induction motor, once turning, keep running in that direction even without its starting winding?
The main winding's pulsating field is equivalent to two equal fields rotating in opposite directions. At standstill each sees the same slip, 1, and their torques cancel. Once the rotor turns, say forward, it moves with the forward field (small slip) and against the backward field (slip near 2). The rotor currents induced by the backward field are at nearly twice line frequency, where the rotor's leakage reactance dominates, so they mostly cancel the backward field rather than produce torque. The forward field meets a rotor at small slip, the normal running condition, and produces nearly all the torque. The difference keeps the rotor going forward, at the cost of extra losses and a 120 Hz torque pulsation that makes single-phase motors noisier.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.