title: Speed control of induction motors
heading: Variable frequency with constant volts per hertz, the constant-torque region below base speed and the constant-power region above it, low-speed voltage boost, and the older methods (pole changing, rotor resistance, slip-power recovery) with their efficiencies
eyebrow: S12 · Lesson 27 · Speed control of induction motors
xp: 50
---

::: hook
An induction motor on a fixed 60 Hz supply runs at nearly fixed speed. For most of the twentieth century, varying it meant wasting power in rotor resistors or building complicated machine sets. Then the inverter of S11 made frequency adjustable, and today most new industrial motors run from a variable-frequency drive. The rule that makes it work is simple: change voltage in proportion to frequency, and the motor's whole torque–speed curve slides along the speed axis unchanged.
:::

::: play
- The 460 V motor's torque–speed curve at drive frequency f, with constant volts per hertz up to 60 Hz and constant voltage above (dashed: the 60 Hz curve).
- Below 60 Hz the curve shifts left, keeping its shape near synchronous speed, so rated torque is available at any speed. At low frequency the stator resistance takes a bigger share of the voltage and the peak sags.
- Above 60 Hz the voltage can't rise, the flux falls as 1/f, and the breakdown torque falls roughly as $1/f^2$.
:::

```sim plot
view: graph
x: n = 0..3000 rpm
y: T = 0..500 N·m
slider: f = 5..100 step 1 = 30 Hz
plot: 3*(259.09*(f/60 + 1 - abs(f/60 - 1))/2)^2*(0.15*1800*f/60/(1800*f/60 - n))/(188.496*f/60*((0.19034 + 0.15*1800*f/60/(1800*f/60 - n))^2 + (0.98966*f/60)^2)) | samples: 900 | label: at f
plot: 3*259.09^2*(0.15*1800/(1800 - n))/(188.496*((0.19034 + 0.15*1800/(1800 - n))^2 + 0.98966^2)) | dashed | color: ch3 | samples: 900 | label: 60 Hz
readout: synchronous speed, rpm = 30*f | digits: 4
readout: breakdown torque, N·m = 1.5*(259.09*(f/60 + 1 - abs(f/60 - 1))/2)^2/(188.496*f/60*(0.19034 + sqrt(0.19034^2 + (0.98966*f/60)^2))) | digits: 4
```

::: predict
## The 4-pole motor runs at 1764 rpm at full load on 60 Hz. With a drive at 30 Hz and half the voltage, about how fast does it run at the same torque?

- [ ] 882 rpm
- [x] About 864 rpm
- [ ] 900 rpm
- [ ] 1764 rpm

::: reveal
With constant volts per hertz the air-gap flux is unchanged, and the rotor needs the same slip frequency, and so the same slip speed, to carry the same current and make the same torque: 36 rpm below the new synchronous speed of 900 rpm, so about 864 rpm. (The equivalent circuit gives 127 N·m at 864 rpm against 133 N·m at 60 Hz, since the stator resistance matters more at low frequency.)
:::
:::

::: nameit
## Constant volts per hertz

The air-gap flux is proportional to $V/f$. Holding $V/f$ at its rated value keeps the flux, and with it the torque per ampere, constant. The slip speed needed for a given torque, $n_s - n$, is then roughly independent of frequency, so the torque–speed curve shifts with $n_s = 120f/P$.

- **Below base speed** (rated frequency): constant torque capability.
- **Low frequencies:** the $I R_1$ drop is no longer negligible against the shrinking voltage, so drives add a **voltage boost** to restore the flux.
- **Above base speed:** voltage is held at its maximum, flux falls as $1/f$, and the available torque at rated current falls as $1/f$, so power stays constant (**field weakening**). Breakdown torque falls as $1/f^2$, which eventually limits the speed range.

## Other methods

- **Pole changing:** windings reconnected for, say, 4 or 8 poles: two fixed speeds.
- **Rotor resistance** (wound rotor): raising $R_2$ raises the slip at a given torque. The rotor can be no more than $1 - s$ efficient, so running at half speed wastes half the air-gap power.
- **Slip-power recovery:** a converter in the rotor circuit returns slip power to the line instead of burning it. The doubly fed induction generator of most wind turbines uses this, with a converter rated only for the slip power, typically ±30% of the machine.
:::

::: example
## A drive runs the motor at 90 Hz with voltage held at 460 V. How does its torque capability change?

::: solution
1. **Flux.** With the voltage held at 460 V, the flux falls to 60/90 of rated.
2. **Torque at rated current.** The torque falls in proportion, so a motor rated 133 N·m at 60 Hz can carry about
   $$\begin{aligned} T &\approx 133 \times \frac{60}{90} \\ &= 89\ \text{N·m} \end{aligned}$$
   at 2700 rpm: the same power.
3. **Breakdown torque.** It falls further, to about
   $$\begin{aligned} T_\max &\approx \left(\frac{60}{90}\right)^2 \times 446 \\ &= 198\ \text{N·m} \end{aligned}$$
   ignoring resistance; the equivalent circuit gives 211 N·m.

**Answer:** at rated current it carries about 89 N·m at 2700 rpm, the same power as at 60 Hz, and its breakdown torque falls to about 198 N·m (211 N·m from the equivalent circuit).
:::
:::

::: example
## A wound-rotor motor (4-pole, 60 Hz) is slowed to 1200 rpm with rotor resistors while delivering 20 kW. Where does the power go?

::: solution
1. **Slip.**
   $$\begin{aligned} s &= \frac{1800 - 1200}{1800} \\ &= 1/3 \end{aligned}$$
2. **Air-gap power.** The mechanical power is $(1 - s)P_\text{ag}$, so $P_\text{ag}$ = 30 kW.
3. **Rotor loss.** The rotor circuit dissipates 10 kW, a third of the air-gap power, mostly in the external resistors.
4. **Compare with a drive.** A drive at 40 Hz would deliver the same 20 kW at 1200 rpm with roughly rated slip.

**Answer:** of the 30 kW crossing the air gap, 20 kW reaches the shaft and 10 kW is burned in the rotor circuit, mostly in the external resistors.
:::
:::

::: example
## The 460 V motor is driven at 6 Hz with its rated slip speed of 36 rpm. What voltage holds its air-gap flux at the rated value, compared with strict V/f?

::: solution
1. **Air-gap voltage.** At 60 Hz and rated load the air-gap voltage is 251 V per phase, so at 6 Hz it must be 25.1 V.
2. **Rotor branch at 6 Hz.** Every reactance shrinks tenfold, and the slip is
   $$\begin{aligned} s &= \frac{36}{180} \\ &= 0.2 \end{aligned}$$
   so $R_2/s$ = 0.75 Ω: the rotor carries the same 33.4 A and makes the same 133 N·m.
3. **Terminal voltage.** The stator's 0.2 Ω now drops a large share of the voltage: the terminals need 32.5 V per phase, 56.4 V line to line.
4. **Compare with strict V/f.** A constant 460/60 V/Hz would give 46.0 V. That 23% extra is the drive's low-speed voltage boost.

**Answer:** 56.4 V line to line (32.5 V per phase), 23% more than the 46.0 V that strict V/f would give.
:::
:::

::: check
given: f = 20 | 40 | 50; P = 2 | 4 | 6; d = 20 | 40 | 60
answer: 120*f/P - d
unit: rpm
tolerance: 0.5%

## A {P}-pole motor needs {d} rpm of slip speed at its load. With constant V/f at {f} Hz, how fast does it run?

::: right
Right. $120f/P - \Delta n$ = {answer} rpm.
:::

::: misses
- [120*f/P] Subtract the slip speed.
- [any] Not yet. The slip speed stays about the same at constant V/f.
:::
:::

::: check
given: V = 230 | 460 | 690; f = 10 | 25 | 45; b = 50 | 60
answer: V*f/b
unit: V
tolerance: 0.5%

## A {V} V, {b} Hz motor runs from a drive at {f} Hz with constant volts per hertz (no boost). What voltage does the drive apply?

::: right
Right. $V_\text{rated}f/f_\text{rated}$ = {answer} V.
:::

::: misses
- [any] Not yet. Scale voltage with frequency.
:::
:::

::: check
given: T = 100 | 400 | 1500; b = 50 | 60; f = 75 | 90 | 120
answer: T*(b/f)^2
unit: N·m
tolerance: 0.5%

## A motor's breakdown torque is {T} N·m at its base frequency of {b} Hz. Above base speed the voltage is held constant. About what is its breakdown torque at {f} Hz (ignoring resistance)?

::: right
Right. $T_\max(f_b/f)^2$ = {answer} N·m.
:::

::: misses
- [T*b/f] Breakdown torque falls as the square of the flux.
- [any] Not yet. Flux falls as 1/f, breakdown torque as $1/f^2$.
:::
:::

::: check
given: T = 50 | 200 | 800; b = 50 | 60; f = 75 | 90 | 120
answer: T*b/f
unit: N·m
tolerance: 0.5%

## At base speed ({b} Hz) a motor is rated {T} N·m. In field weakening at {f} Hz, what torque can it carry at rated current?

::: right
Right. $T(f_b/f)$ = {answer} N·m: constant power.
:::

::: misses
- [T*(b/f)^2] At rated current, torque follows flux, which falls as 1/f.
- [any] Not yet. Flux falls as 1/f.
:::
:::

::: check
given: P = 4 | 6; f = 50 | 60; r = 0.2 | 0.35 | 0.5; let n = 120*f/P*(1 - r)
answer: 100*n/(120*f/P)
unit: %
tolerance: 0.5%

## A {P}-pole, {f} Hz wound-rotor motor is slowed to {n} rpm with rotor resistance. What's the highest possible rotor efficiency?

::: right
Right. $1 - s$ = {answer}%.
:::

::: misses
- [any] Not yet. $P_\text{mech} = (1 - s)P_\text{ag}$.
:::
:::

::: check
given: P = 1.5 | 3 | 5; r = 0.2 | 0.3
answer: P*r
unit: MW
tolerance: 0.5%

## A {P} MW doubly fed induction generator runs over a slip range of ±{r}. About what power must its rotor converter handle?

::: right
Right. The slip power, about $|s|P$ = {answer} MW.
:::

::: misses
- [P] Only the slip power passes through the rotor converter.
- [any] Not yet. The rotor circuit carries the slip's share.
:::
:::

::: check
kind: parts
given: f = 75 | 90 | 120; T = 50 | 100; m = 300 | 450; b = 60 | 50

## A motor rated {T} N·m at its {b} Hz base frequency, with {m} N·m of breakdown torque, is driven at {f} Hz with its voltage held at rated.

::: part
answer: T*b/f
unit: N·m
tolerance: 0.5%

### About how much torque can it carry at rated current?

::: misses
- [T*(b/f)^2] At rated current, torque falls as the flux: 1/f.
- [any] Flux falls as $b/f$.
:::
:::

::: part
answer: m*(b/f)^2
unit: N·m
tolerance: 0.5%

### About what breakdown torque does it have, ignoring stator resistance?

::: misses
- [m*b/f] Breakdown torque falls as the square.
- [any] $(b/f)^2$ times.
:::
:::
:::

::: check
kind: derivation
vars: n = 500..3600, P = 2..8, f = 10..120, A = 1000..100000

## A wound-rotor induction motor with P poles on f hertz runs at n rpm, with air-gap power A.

::: step
answer: (120*f/P - n)/(120*f/P)

### What is its slip?
:::

::: step
answer: (120*f/P - n)/(120*f/P)*A

### How much power does the rotor circuit dissipate?
:::

::: right
Right. Rotor resistance control wastes the slip fraction of the air-gap power.
:::
:::

::: explain
## Why does keeping volts per hertz constant give an induction motor the same torque capability at any speed below base speed?

::: model
The induced voltage in the stator is proportional to the frequency times the air-gap flux, so with the stator resistance neglected the flux is set by V/f. Holding V/f constant holds the flux constant. The torque is the flux times the rotor current that it acts on, and the rotor current depends on the slip frequency, the rate at which the field sweeps past the rotor bars, not on the supply frequency itself. So at any supply frequency, the same slip speed gives the same rotor current and the same torque, and the torque–speed curve just slides along the speed axis. Below a few hertz the stator resistance's drop becomes a large fraction of the reduced voltage and the flux sags, so drives boost the voltage there.
:::
:::

::: practice

::: check
given: f = 10 | 55; P = 4 | 8; d = 15 | 80
answer: 120*f/P - d
unit: rpm
tolerance: 0.5%

## Speed: {P} poles, {f} Hz, {d} rpm slip?

::: misses
- [any] $120f/P - \Delta n$.
:::
:::

::: check
given: T = 40 | 2000; b = 50 | 60; f = 70 | 150
answer: T*(b/f)^2
unit: N·m
tolerance: 0.5%

## Breakdown torque at {f} Hz: {T} N·m at {b} Hz?

::: misses
- [any] $T(f_b/f)^2$.
:::
:::

::: check
given: P = 2 | 8; r = 0.15 | 0.35
answer: P*r
unit: MW
tolerance: 0.5%

## DFIG converter rating: {P} MW, slip ±{r}?

::: misses
- [any] $|s|P$.
:::
:::
:::