S12 Electric machines · Practice
Starting, rotor design and induction generators
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
Direct on line, a motor draws 6.5 times rated current with 1.2 times rated torque. Started wye–delta, what line current (times rated) does it draw?
Check
A motor that draws 6.5 times rated current direct on line starts through an autotransformer on its 0.5 tap. What line current (times rated) flows?
Check
A motor's direct-on-line starting torque is 1.8 times rated. With a soft starter at 0.4 of rated voltage, what's its starting torque?
Check
How deep does 2 Hz current penetrate a rotor bar of resistivity 2.8 × 10⁻⁸ Ω·m?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A wind turbine drives a 4-pole, 50 Hz induction generator at 1545 rpm. What's its slip?
Check
An induction generator's magnetizing reactance is 20 Ω per phase at 50 Hz. What capacitance per phase lets it self-excite?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
A motor starts at 6 times rated current and 1.2 times rated torque. It's started through an autotransformer on its 0.8 tap.
(a)
What starting current does the motor draw, in multiples of rated?
(b)
What does the line supply?
(c)
What starting torque results, in multiples of rated?
Check
Line current, autotransformer tap 0.5, 4× DOL?
Check
Skin depth: 0.5 Hz, ρ = 1.7 × 10⁻⁸ Ω·m?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
Self-excitation capacitance: = 5 Ω, 50 Hz?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in S12