S12 · Lesson 9 · Generated voltage and torque in AC machines
Flux per pole of a sinusoidal air-gap field, the induced voltage of a distributed winding, harmonic voltages and how pitch removes them, torque from the interaction of two fields and their angle, and sizing a machine from its air-gap shear stress
Turn lesson 8 around: if a rotating field sweeps past a stationary winding, it induces a voltage in it, and if a winding's current sets up a field in the presence of another, the two pull on each other. These two results give the voltage rating and the torque rating of every AC machine, and with them a rule of thumb that sizes a motor from little more than its torque: the tangential stress its air gap can sustain.
- The voltage induced in one phase by a rotating field whose flux density contains a 5th harmonic, b times the fundamental's peak, for a winding of coil pitch ρ.
- At full pitch the voltage carries the field's full 5th harmonic; at ρ = 0.8 the 5th harmonic's pitch factor is zero and the voltage is a clean sine, at the cost of 5% of the fundamental.
- The readout gives the 5th harmonic's share of the voltage.
Predict
A 4-pole, 60 Hz generator has a rotor 0.3 m in diameter and 0.25 m long, with a sinusoidal gap field of 0.9 T peak. Each phase has 48 series turns with winding factor 0.927. What's the phase voltage?
The flux per pole is = 1 × 0.9 × 0.25 × 0.15 = 0.0338 Wb, and = 4.44 × 60 × 0.927 × 48 × 0.0338 = 400 V RMS, 693 V line to line in Y.
Name it
Flux per pole
A sinusoidal air-gap field of peak in a P-pole machine with rotor radius r and length l carries, under each pole,
Induced voltage
As the field rotates past a phase with series turns and winding factor , the induced voltage has RMS value
A space harmonic h of the field induces a voltage harmonic h with relative size ; pitch and distribution suppress them as they suppress MMF harmonics.
Torque from two fields
A stator MMF and a rotor MMF, or a resultant flux and a rotor MMF, pull toward alignment. For a machine with resultant flux per pole and rotor MMF at an angle (electrical) between them,
Torque peaks at 90°; every machine in this course is a particular way of creating and holding that angle.
Sizing by shear stress
The average tangential force per unit area of rotor surface, σ, is about 10 to 30 kPa for air-cooled industrial machines and up to 100 kPa with liquid cooling. The torque is σ times the surface area times the radius:
so a machine's size is set by its torque, and a faster machine of the same size delivers proportionally more power.
Worked example
Size a machine from shear stress: 20 kPa on a rotor 0.3 m in diameter and 0.25 m long, at 1800 rpm.
Show the solution
- Rotor volume.
- Torque.
- Power. At 1800 rpm (188.5 rad/s) that's 133 kW.
- Doubling the speed. The same frame at 3600 rpm could deliver about 266 kW, which is why high-speed machines are so compact, and why low-speed direct-drive wind generators are so large.
Answer about 707 N·m, which is 133 kW at 1800 rpm.
Worked example
The 4-pole machine has a resultant flux of 0.0338 Wb per pole and a rotor MMF of 600 A·turns per pole at 30° to it. What torque does it make?
Show the solution
- Torque at 30°.
- At 90°. The same fields would give twice that, 127 N·m.
- Beyond 90°. The torque falls, and a synchronous machine would pull out of step.
Answer 63.7 N·m.
Worked example
A 4-pole, 60 Hz machine has a rotor 0.2 m in diameter and 0.2 m long, a peak air-gap field of 0.8 T, and 96 series turns per phase with = 0.927. What voltage does each phase generate?
Show the solution
- Flux per pole.
- Phase voltage. per phase, 657 V line to line in Y.
- Designing for 460 V. To make a 460 V machine the designer would use 67 turns per phase, or a shorter stack.
Answer each phase generates 380 V, 657 V line to line in Y.
Check
A 4-pole machine with rotor radius 0.2 m and length 0.4 m has a sinusoidal gap field of 0.6 T peak. What's the flux per pole?
Write units the way you normally would: 1.5 Wb, 1500 mWb and 0.0015 kWb are the same answer.
Check
A phase with 150 series turns and winding factor 0.9 sees 0.05 Wb per pole at 50 Hz. What RMS voltage is induced?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A field's 5th space harmonic is 0.15 of its fundamental. With concentrated coils of 0.75 pitch, how large is the 5th harmonic of the phase voltage relative to the fundamental?
Check
A rotor of diameter 0.1 m and length 0.4 m runs at an air-gap shear stress of 20 kPa. What torque does it produce?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 4-pole machine has resultant flux 0.02 Wb per pole and rotor MMF 1200 A·turns per pole at 70° electrical. What torque does it produce?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A motor delivers 50 kW at 900 rpm. What torque?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 4-pole machine has a peak air-gap field of 0.7 T, rotor radius 0.15 m and length 0.3 m, and 40 series turns per phase with = 0.92, at 50 Hz.
(a)
What is its flux per pole?
Write units the way you normally would: 1.5 Wb, 1500 mWb and 0.0015 kWb are the same answer.
(b)
What RMS voltage does each phase generate?
Check
A machine's rotor has radius r and length l, with an average shear stress s on its surface, turning at n rpm.
Step 1
What torque does it make?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What power?
Explain why
Why does a machine's physical size depend on its torque rather than its power?
The force a machine can make is limited by how hard its air gap can be pulled tangentially: the product of the flux density the iron can carry before saturating and the current per unit of circumference the conductors can carry before overheating. Both are set by materials and cooling, not by speed, so the torque per unit of rotor volume is roughly fixed, about 2σ with σ in the tens of kilopascals. Power is torque times speed, so a machine that turns faster delivers more power from the same volume. That's why aircraft generators and high-speed spindles are small for their rating, and why a slow wind turbine generator or a ship's propulsion motor is enormous.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.