title: Generated voltage and torque in AC machines
heading: Flux per pole of a sinusoidal air-gap field, the induced voltage of a distributed winding, harmonic voltages and how pitch removes them, torque from the interaction of two fields and their angle, and sizing a machine from its air-gap shear stress
eyebrow: S12 · Lesson 9 · Generated voltage and torque in AC machines
xp: 50
---

::: hook
Turn lesson 8 around: if a rotating field sweeps past a stationary winding, it induces a voltage in it, and if a winding's current sets up a field in the presence of another, the two pull on each other. These two results give the voltage rating and the torque rating of every AC machine, and with them a rule of thumb that sizes a motor from little more than its torque: the tangential stress its air gap can sustain.
:::

::: play
- The voltage induced in one phase by a rotating field whose flux density contains a 5th harmonic, b times the fundamental's peak, for a winding of coil pitch ρ.
- At full pitch the voltage carries the field's full 5th harmonic; at ρ = 0.8 the 5th harmonic's pitch factor is zero and the voltage is a clean sine, at the cost of 5% of the fundamental.
- The readout gives the 5th harmonic's share of the voltage.
:::

```sim plot
view: graph
x: x = 0..360 °
y: e = -1.4..1.4
slider: b = 0..0.3 step 0.01 = 0.15
slider: r = 0.6..1 step 0.01 = 1
plot: sin(r*pi/2)*cos(x*pi/180) + b*sin(5*r*pi/2)*cos(5*x*pi/180) | samples: 600 | label: phase voltage
plot: cos(x*pi/180) | dashed | color: ch3 | label: pure fundamental, full pitch
readout: 5th harmonic / fundamental = abs(b*sin(5*r*pi/2)/sin(r*pi/2)) | digits: 3
```

::: predict
## A 4-pole, 60 Hz generator has a rotor 0.3 m in diameter and 0.25 m long, with a sinusoidal gap field of 0.9 T peak. Each phase has 48 series turns with winding factor 0.927. What's the phase voltage?

- [ ] About 40 V
- [x] About 400 V
- [ ] About 4 kV
- [ ] It depends on the load

::: reveal
The flux per pole is $\frac{4}{P}B_\text{peak}lr$ = 1 × 0.9 × 0.25 × 0.15 = 0.0338 Wb, and $E = \sqrt{2}\pi fk_wN_\text{ph}\Phi_p$ = 4.44 × 60 × 0.927 × 48 × 0.0338 = 400 V RMS, 693 V line to line in Y.
:::
:::

::: nameit
## Flux per pole

A sinusoidal air-gap field of peak $B_\text{peak}$ in a P-pole machine with rotor radius r and length l carries, under each pole,

$$\Phi_p = \frac{4}{P}B_\text{peak}lr$$

## Induced voltage

As the field rotates past a phase with $N_\text{ph}$ series turns and winding factor $k_w$, the induced voltage has RMS value

$$E = \sqrt{2}\pi fk_wN_\text{ph}\Phi_p \approx 4.44fk_wN_\text{ph}\Phi_p$$

A space harmonic h of the field induces a voltage harmonic h with relative size $(B_h/B_1)(k_{wh}/k_{w1})$; pitch and distribution suppress them as they suppress MMF harmonics.

## Torque from two fields

A stator MMF and a rotor MMF, or a resultant flux and a rotor MMF, pull toward alignment. For a machine with resultant flux per pole $\Phi_{sr}$ and rotor MMF $F_r$ at an angle $\delta_r$ (electrical) between them,

$$T = \frac{\pi}{2}\left(\frac{P}{2}\right)^2\Phi_{sr}F_r\sin\delta_r$$

Torque peaks at 90°; every machine in this course is a particular way of creating and holding that angle.

## Sizing by shear stress

The average tangential force per unit area of rotor surface, σ, is about 10 to 30 kPa for air-cooled industrial machines and up to 100 kPa with liquid cooling. The torque is σ times the surface area times the radius:

$$T = 2\sigma V_r, \qquad V_r = \pi r^2l$$

so a machine's size is set by its torque, and a faster machine of the same size delivers proportionally more power.
:::

::: example
## Size a machine from shear stress: 20 kPa on a rotor 0.3 m in diameter and 0.25 m long, at 1800 rpm.

::: solution
1. **Rotor volume.**
   $$\begin{aligned} V_r &= \pi \times 0.15^2 \times 0.25 \\ &= 0.0177\ \text{m}^3 \end{aligned}$$
2. **Torque.**
   $$\begin{aligned} T &= 2\sigma V_r \\ &= 2 \times 20\,000 \times 0.01767 \\ &= 707\ \text{N·m} \end{aligned}$$
3. **Power.** At 1800 rpm (188.5 rad/s) that's 133 kW.
4. **Doubling the speed.** The same frame at 3600 rpm could deliver about 266 kW, which is why high-speed machines are so compact, and why low-speed direct-drive wind generators are so large.

**Answer:** about 707 N·m, which is 133 kW at 1800 rpm.
:::
:::

::: example
## The 4-pole machine has a resultant flux of 0.0338 Wb per pole and a rotor MMF of 600 A·turns per pole at 30° to it. What torque does it make?

::: solution
1. **Torque at 30°.**
   $$\begin{aligned} T &= \frac{\pi}{2} \times 2^2 \times 0.0338 \\ &\quad \times 600 \times \sin 30° \\ &= 63.7\ \text{N·m} \end{aligned}$$
2. **At 90°.** The same fields would give twice that, 127 N·m.
3. **Beyond 90°.** The torque falls, and a synchronous machine would pull out of step.

**Answer:** 63.7 N·m.
:::
:::

::: example
## A 4-pole, 60 Hz machine has a rotor 0.2 m in diameter and 0.2 m long, a peak air-gap field of 0.8 T, and 96 series turns per phase with $k_w$ = 0.927. What voltage does each phase generate?

::: solution
1. **Flux per pole.**
   $$\begin{aligned} \Phi_p &= \frac{4}{P}B_\text{peak}lr \\ &= 1 \times 0.8 \times 0.2 \times 0.1 \\ &= 0.016\ \text{Wb} \end{aligned}$$
2. **Phase voltage.**
   $$\begin{aligned} E &= \sqrt2\pi fk_wN_\text{ph}\Phi_p \\ &= 4.443 \times 60 \times 0.927 \\ &\quad \times 96 \times 0.016 \\ &= 380\ \text{V} \end{aligned}$$
   per phase, 657 V line to line in Y.
3. **Designing for 460 V.** To make a 460 V machine the designer would use 67 turns per phase, or a shorter stack.

**Answer:** each phase generates 380 V, 657 V line to line in Y.
:::
:::

::: check
given: P = 2 | 4 | 6; B = 0.6 | 0.9; l = 0.1 | 0.4; r = 0.05 | 0.2
answer: 4/P*B*l*r
unit: Wb
tolerance: 0.5%

## A {P}-pole machine with rotor radius {r} m and length {l} m has a sinusoidal gap field of {B} T peak. What's the flux per pole?

::: right
Right. $\frac{4}{P}B_\text{peak}lr$ = {answer} Wb.
:::

::: misses
- [2/P*B*l*r] Integrate the cosine over a pole: the average of a half sine is 2/π of its peak, over a pole arc of $2\pi r/P$.
- [any] Not yet. Integrate $B$ over one pole's area.
:::
:::

::: check
given: f = 50 | 60; k = 0.9 | 0.95; N = 20 | 60 | 150; F = 0.01 | 0.05
answer: sqrt(2)*pi*f*k*N*F
unit: V
tolerance: 0.5%

## A phase with {N} series turns and winding factor {k} sees {F} Wb per pole at {f} Hz. What RMS voltage is induced?

::: right
Right. $\sqrt{2}\pi fk_wN\Phi_p$ = {answer} V.
:::

::: misses
- [2*pi*f*k*N*F] That's the peak voltage; divide by √2 for RMS.
- [any] Not yet. $E = 4.44fk_wN\Phi$.
:::
:::

::: check
given: b = 0.05 | 0.15 | 0.25; r = 0.75 | 0.833 | 0.9
answer: abs(b*sin(5*r*pi/2)/sin(r*pi/2))
tolerance: 0.5%

## A field's 5th space harmonic is {b} of its fundamental. With concentrated coils of {r} pitch, how large is the 5th harmonic of the phase voltage relative to the fundamental?

::: right
Right. $(B_5/B_1)(k_{p5}/k_{p1})$ = {answer}.
:::

::: misses
- [b] Include the pitch factors.
- [any] Not yet. Scale by the ratio of pitch factors.
:::
:::

::: check
given: s = 10 | 20 | 40; D = 0.1 | 0.3 | 0.6; l = 0.1 | 0.4
answer: 2*s*1e3*pi*(D/2)^2*l
unit: N·m
tolerance: 0.5%

## A rotor of diameter {D} m and length {l} m runs at an air-gap shear stress of {s} kPa. What torque does it produce?

::: right
Right. $2\sigma\pi r^2l$ = {answer} N·m.
:::

::: misses
- [s*1e3*pi*(D/2)^2*l] The surface area is $2\pi rl$, times the radius.
- [any] Not yet. Stress × rotor surface × radius.
:::
:::

::: check
given: P = 2 | 4 | 6; F = 0.02 | 0.08; R = 300 | 1200; d = 20 | 45 | 70
answer: pi/2*(P/2)^2*F*R*sin(d*pi/180)
unit: N·m
tolerance: 0.5%

## A {P}-pole machine has resultant flux {F} Wb per pole and rotor MMF {R} A·turns per pole at {d}° electrical. What torque does it produce?

::: right
Right. $\frac{\pi}{2}(P/2)^2\Phi_{sr}F_r\sin\delta_r$ = {answer} N·m.
:::

::: misses
- [any] Not yet. The torque grows with both fields and the sine of the angle between them.
:::
:::

::: check
given: P = 5 | 50 | 500; n = 900 | 1800 | 3600
answer: P*1000/(2*pi*n/60)
unit: N·m
tolerance: 0.5%

## A motor delivers {P} kW at {n} rpm. What torque?

::: right
Right. $P/\omega$ = {answer} N·m.
:::

::: misses
- [P*1000/n] Convert rpm to rad/s: $\omega = 2\pi n/60$.
- [any] Not yet. Power over angular speed.
:::
:::

::: check
kind: parts
given: P = 2 | 4 | 6; B = 0.7 | 0.9; l = 0.1 | 0.3; r = 0.05 | 0.15; f = 50 | 60; N = 40 | 120; k = 0.92 | 0.95

## A {P}-pole machine has a peak air-gap field of {B} T, rotor radius {r} m and length {l} m, and {N} series turns per phase with $k_w$ = {k}, at {f} Hz.

::: part
answer: 4/P*B*l*r
unit: Wb
tolerance: 0.5%

### What is its flux per pole?

::: misses
- [2/P*B*l*r] The pole area is $2\pi rl/P$ and the average of a sine's half cycle is $2/\pi$ of its peak.
- [any] $\Phi_p = (4/P)B_\text{peak}lr$.
:::
:::

::: part
answer: sqrt(2)*pi*f*k*N*4/P*B*l*r
unit: V
tolerance: 0.5%

### What RMS voltage does each phase generate?

::: misses
- [any] $\sqrt2\pi fk_wN_\text{ph}\Phi_p$.
:::
:::
:::

::: check
kind: derivation
vars: s = 5000..100000, r = 0.02..1, l = 0.02..2, n = 100..20000

## A machine's rotor has radius r and length l, with an average shear stress s on its surface, turning at n rpm.

::: step
answer: 2*s*pi*r^2*l

### What torque does it make?
:::

::: step
answer: 2*s*pi*r^2*l*2*pi*n/60

### What power?
:::

::: right
Right. Torque scales with rotor volume; power with volume times speed.
:::
:::

::: explain
## Why does a machine's physical size depend on its torque rather than its power?

::: model
The force a machine can make is limited by how hard its air gap can be pulled tangentially: the product of the flux density the iron can carry before saturating and the current per unit of circumference the conductors can carry before overheating. Both are set by materials and cooling, not by speed, so the torque per unit of rotor volume is roughly fixed, about 2σ with σ in the tens of kilopascals. Power is torque times speed, so a machine that turns faster delivers more power from the same volume. That's why aircraft generators and high-speed spindles are small for their rating, and why a slow wind turbine generator or a ship's propulsion motor is enormous.
:::
:::

::: practice

::: check
given: f = 50 | 400; k = 0.88 | 0.96; N = 10 | 200; F = 0.002 | 0.08
answer: sqrt(2)*pi*f*k*N*F
unit: V
tolerance: 0.5%

## EMF: {f} Hz, $k_w$ = {k}, {N} turns, {F} Wb?

::: misses
- [any] $4.44fk_wN\Phi$.
:::
:::

::: check
given: s = 8 | 50; D = 0.05 | 1; l = 0.05 | 0.8
answer: 2*s*1e3*pi*(D/2)^2*l
unit: N·m
tolerance: 0.5%

## Torque: σ = {s} kPa, D = {D} m, l = {l} m?

::: misses
- [any] $2\sigma\pi r^2l$.
:::
:::

::: check
given: P = 0.5 | 200; n = 750 | 3000
answer: P*1000/(2*pi*n/60)
unit: N·m
tolerance: 0.5%

## Torque: {P} kW at {n} rpm?

::: misses
- [any] $P/\omega$.
:::
:::
:::