title: Windings and the air-gap MMF
heading: The square-wave MMF of a concentrated coil and its fundamental, multipole machines and electrical degrees, distributing and short-pitching coils to approach a sinusoidal MMF, pitch, distribution and winding factors for the fundamental and the harmonics, and the air-gap flux density they produce
eyebrow: S12 · Lesson 7 · Windings and the air-gap MMF
xp: 50
---

::: hook
A single coil in a slot produces a magnetomotive force around the air gap that jumps abruptly at the coil sides: a square wave, full of harmonics that would make a machine noisy, lossy and jerky. Real AC machines spread each phase over several slots and shorten each coil's span. The resulting staircase is close to a sine, and two numbers, the pitch factor and the distribution factor, say how much of the fundamental survives and how much of each harmonic is left.
:::

::: play
- The winding factor of a three-phase winding against coil pitch ρ (the coil's span as a fraction of a pole pitch), for the fundamental and the 5th and 7th harmonics, with q slots per pole per phase.
- At ρ = 5/6 the 5th and 7th harmonics fall to about a quarter of their full-pitch values while the fundamental loses only 3.4%.
- Raising q (spreading each phase over more slots) lowers the harmonics further; the fundamental's distribution factor approaches 3/π = 0.955.
:::

```sim plot
view: graph
x: r = 0.5..1
y: k = 0..1
slider: q = 1..6 step 1 = 3
plot: abs(sin(r*pi/2)*sin(pi/6)/(q*sin(pi/(6*q)))) | samples: 300 | label: fundamental
plot: abs(sin(5*r*pi/2)*sin(5*pi/6)/(q*sin(5*pi/(6*q)))) | samples: 300 | color: ch3 | label: 5th
plot: abs(sin(7*r*pi/2)*sin(7*pi/6)/(q*sin(7*pi/(6*q)))) | samples: 300 | color: ch4 | label: 7th
readout: distribution factor = sin(pi/6)/(q*sin(pi/(6*q))) | digits: 4
readout: fundamental winding factor at 5/6 pitch = sin(5*pi/12)*sin(pi/6)/(q*sin(pi/(6*q))) | digits: 4
```

::: predict
## A three-phase winding with 3 slots per pole per phase uses coils of 5/6 pitch. What fraction of the fundamental MMF does it keep, compared with full-pitch concentrated coils?

- [ ] 0.50
- [ ] 0.81
- [x] 0.93
- [ ] 1.00

::: reveal
The pitch factor is $\sin(\frac{5}{6} \cdot 90°)$ = 0.966 and the distribution factor $\frac{\sin(30°)}{3\sin(10°)}$ = 0.960, so the winding factor is 0.927. For that 7% loss of fundamental, the 5th harmonic falls to 0.056 and the 7th to 0.046 of what full-pitch concentrated coils would give.
:::
:::

::: nameit
## The MMF of a coil

N turns carrying current i, with sides 180° apart, produce an MMF around the gap that is +Ni/2 over one half and −Ni/2 over the other. Its fundamental has amplitude $\frac{4}{\pi}\frac{Ni}{2}$, and the square wave also contains every odd harmonic h at 1/h of that.

## Poles and electrical degrees

A machine with P poles repeats its pattern P/2 times around the gap. Angles measured in **electrical degrees** are P/2 times mechanical degrees; all winding geometry is described electrically.

## Distribution and pitch

With q slots per pole per phase, the coils of a phase sit γ = 60°/q apart electrically, and their MMFs add as phasors:

$$k_d = \frac{\sin(q\gamma/2)}{q\sin(\gamma/2)}, \qquad k_p = \sin\left(\rho\frac{\pi}{2}\right)$$

with ρ the coil pitch as a fraction of a pole pitch. For harmonic h replace γ by hγ and $\rho\pi/2$ by $h\rho\pi/2$. The **winding factor** is $k_w = k_pk_d$. A 5/6 pitch reduces the 5th and 7th harmonics, which are the most troublesome in three-phase machines.

## The fundamental MMF

A phase with $N_\text{ph}$ series turns spread over P poles, carrying i, has a fundamental MMF of peak

$$F_1 = \frac{4}{\pi}\frac{k_wN_\text{ph}}{P}i$$

per pole, and across a uniform gap g it produces a flux density $B = \mu_0F/g$.
:::

::: example
## Find the winding factors of a winding with q = 3 and 5/6 pitch for the fundamental, 5th and 7th harmonics.

::: solution
1. **Slot angle.** With q = 3, γ = 20°.
2. **Fundamental.**
   $$\begin{aligned} k_p &= \sin 75° \\ &= 0.966 \\ k_d &= \frac{0.5}{3\sin 10°} \\ &= 0.960 \\ k_w &= 0.927 \end{aligned}$$
3. **5th harmonic.**
   $$\begin{aligned} k_p &= |\sin 375°| \\ &= 0.259 \\ k_d &= \left|\frac{\sin 150°}{3\sin 50°}\right| \\ &= 0.218 \\ k_w &= 0.056 \end{aligned}$$
4. **7th harmonic.**
   $$\begin{aligned} k_w &= 0.259 \times 0.177 \\ &= 0.046 \end{aligned}$$
5. **The 5th against the fundamental.** After accounting for the 1/h of the square wave, the 5th harmonic is
   $$\frac{0.056}{5 \times 0.927} = 1.2\%$$
   of the fundamental.

**Answer:** $k_w$ is 0.927 for the fundamental, 0.056 for the 5th and 0.046 for the 7th. With the square wave's 1/h, the 5th harmonic comes to 1.2% of the fundamental.
:::
:::

::: example
## A 4-pole phase winding has 96 series turns with $k_w$ = 0.927 and carries 10 A RMS. Find its peak fundamental MMF and the flux density across a 1 mm gap when all three phases act together.

::: solution
1. **Peak current.** 10 A RMS peaks at 14.14 A.
2. **Fundamental MMF.**
   $$\begin{aligned} F_1 &= \frac{4}{\pi} \times \frac{0.927 \times 96}{4} \\ &\quad \times 14.14 \\ &= 401\ \text{A·turns} \end{aligned}$$
   per pole.
3. **All three phases.** Lesson 8 shows that three phases together produce a rotating MMF of 3/2 that peak:
   $$\begin{aligned} F &= \tfrac{3}{2}F_1 \\ &= 601\ \text{A·turns} \end{aligned}$$
4. **Gap flux density.** Across 1 mm,
   $$\begin{aligned} B &= \frac{\mu_0 \times 601}{0.001} \\ &= 0.755\ \text{T} \end{aligned}$$

**Answer:** the peak fundamental MMF is 401 A·turns per pole. All three phases together give 601 A·turns, which drives 0.755 T across the 1 mm gap.
:::
:::

::: example
## A 6-pole stator has 36 slots and coils pitched 5 slots (5/6 of the 6-slot pole pitch). Find its winding factors for the fundamental, the 5th, 7th, 11th and 13th harmonics.

::: solution
1. **Slots per pole per phase.**
   $$\begin{aligned} q &= \frac{36}{6 \times 3} \\ &= 2 \end{aligned}$$
   and γ = 30°.
2. **Fundamental.**
   $$\begin{aligned} k_d &= \frac{\sin 30°}{2\sin 15°} \\ &= 0.966 \\ k_p &= \sin 75° \\ &= 0.966 \\ k_w &= 0.933 \end{aligned}$$
3. **5th and 7th.** They get 0.259 from each factor, 0.067 overall.
4. **11th and 13th.** At $6q \pm 1$, they get 0.966 from each factor, the same 0.933 as the fundamental.
5. **Slot harmonics.** These are the **slot harmonics**, which no choice of pitch or distribution can reduce without also reducing the fundamental. Skewing the slots by one slot pitch or using more slots per pole per phase is the usual remedy.

**Answer:** $k_w$ is 0.933 for the fundamental, 0.067 for the 5th and 7th, and 0.933 again for the 11th and 13th, which are slot harmonics.
:::
:::

::: check
given: r = 0.667 | 0.8 | 0.833 | 0.9
answer: sin(r*pi/2)
tolerance: 0.5%

## A coil spans {r} of a pole pitch. What's its pitch factor for the fundamental?

::: right
Right. $\sin(\rho\pi/2)$ = {answer}.
:::

::: misses
- [r] The pitch factor is a sine, not the fraction itself.
- [any] Not yet. The coil's two sides see voltages $\rho \times 180°$ apart.
:::
:::

::: check
given: q = 2 | 3 | 4 | 5
answer: sin(pi/6)/(q*sin(pi/(6*q)))
tolerance: 0.2%

## A three-phase winding has {q} slots per pole per phase in a 60° phase belt. What's its distribution factor?

::: right
Right. With γ = 60°/q, $\sin(q\gamma/2)/(q\sin(\gamma/2))$ = {answer}.
:::

::: misses
- [any] Not yet. The q coil voltages add as phasors γ apart.
:::
:::

::: check
given: h = 5 | 7; r = 0.8 | 0.833
answer: abs(sin(h*r*pi/2))
tolerance: 0.5%

## A winding uses coils of {r} pitch. What's its pitch factor for the {h}th harmonic?

::: right
Right. $|\sin(h\rho\pi/2)|$ = {answer}.
:::

::: misses
- [sin(r*pi/2)] That's the fundamental's; for harmonic h the angle is h times larger.
- [any] Not yet. Multiply the angle by h.
:::
:::

::: check
given: q = 2 | 3 | 4; r = 0.8 | 0.833 | 0.889
answer: sin(r*pi/2)*sin(pi/6)/(q*sin(pi/(6*q)))
tolerance: 0.5%

## A winding has q = {q} slots per pole per phase and {r} pitch. What's its fundamental winding factor?

::: right
Right. $k_pk_d$ = {answer}.
:::

::: misses
- [sin(r*pi/2)] Include the distribution factor.
- [any] Not yet. Pitch factor times distribution factor.
:::
:::

::: check
given: N = 48 | 120 | 240; k = 0.9 | 0.93; P = 2 | 4 | 6; i = 5 | 20
answer: 4/pi*k*N/P*i*sqrt(2)
unit: A
tolerance: 0.5%

## A {P}-pole phase winding has {N} series turns with winding factor {k} and carries {i} A RMS. What's the peak of its fundamental MMF per pole (in ampere-turns)?

::: right
Right. $\frac{4}{\pi}\frac{k_wN_\text{ph}}{P}\sqrt{2}I$ = {answer} A·turns.
:::

::: misses
- [4/pi*k*N/P*i] Use the current's peak, √2 times its RMS value.
- [any] Not yet. $F_1 = \frac{4}{\pi}\frac{k_wN}{P}i$ at the current's peak.
:::
:::

::: check
given: F = 200 | 800 | 2000; g = 0.5 | 1 | 2
answer: 4e-7*pi*F/(g*1e-3)
unit: T
tolerance: 0.5%

## An MMF of {F} ampere-turns per pole acts across a {g} mm air gap (ideal iron). What flux density does it produce?

::: right
Right. $\mu_0F/g$ = {answer} T.
:::

::: misses
- [any] Not yet. All the MMF drops across the gap.
:::
:::

::: check
kind: parts
given: Q = 24 | 36 | 48 | 72; P = 2 | 4; r = 0.8 | 0.833 | 0.9

## A three-phase, {P}-pole stator has {Q} slots, with coils pitched at {r} of a pole pitch.

::: part
answer: Q/(3*P)
tolerance: 0.5%

### How many slots per pole per phase?

::: misses
- [any] Slots over poles times phases.
:::
:::

::: part
answer: sin(Q/(3*P)*(60/(Q/(3*P)))/2*pi/180)/(Q/(3*P)*sin(60/(Q/(3*P))/2*pi/180))
tolerance: 0.5%

### What is the fundamental distribution factor?

::: misses
- [any] $\sin(q\gamma/2)/(q\sin(\gamma/2))$ with $\gamma = 60°/q$.
:::
:::

::: part
answer: sin(Q/(3*P)*(60/(Q/(3*P)))/2*pi/180)/(Q/(3*P)*sin(60/(Q/(3*P))/2*pi/180))*sin(r*pi/2)
tolerance: 0.5%

### What is the fundamental winding factor?

::: misses
- [any] $k_pk_d$ with $k_p = \sin(\rho\pi/2)$.
:::
:::
:::

::: check
kind: derivation
vars: q = 1..8, r = 0.6..1, h = 1..15

## A winding has q slots per pole per phase and pitch ρ = r. Consider harmonic h.

::: step
answer: abs(sin(h*q*(pi/(3*q))/2)/(q*sin(h*(pi/(3*q))/2)))

### What is its distribution factor (magnitude)?
:::

::: step
answer: abs(sin(h*r*pi/2))

### What is its pitch factor (magnitude)?
:::

::: right
Right. Both factors depend on h; slot harmonics at $h = 6q \pm 1$ keep the fundamental's distribution factor.
:::
:::

::: explain
## Why do machine designers short-pitch their coils, giving up some of the fundamental?

::: model
A full-pitch coil's sides sit exactly a pole pitch apart, so its MMF is a square wave with every odd harmonic at 1/h of the fundamental's strength. Those space harmonics produce extra losses, torque ripple, noise and voltage harmonics in a generator. Shortening the coil's span by a fraction of a pole pitch shifts its two sides so that, for a chosen harmonic, their contributions nearly cancel, while for the fundamental they still almost add. A 5/6 pitch, for example, cuts the 5th and 7th harmonics, the largest in a three-phase machine since the triplen ones cancel between phases, to about a quarter, while reducing the fundamental by only 3.4%. A slightly larger machine is a cheap price for a much cleaner field.
:::
:::

::: practice

::: check
given: r = 0.7 | 0.75 | 0.8 | 0.833 | 0.875 | 0.9 | 0.95
answer: sin(r*pi/2)
tolerance: 0.5%

## Pitch factor at {r} pitch?

::: misses
- [any] $\sin(\rho\pi/2)$.
:::
:::

::: check
given: q = 2 | 6; r = 0.78 | 0.92
answer: sin(r*pi/2)*sin(pi/6)/(q*sin(pi/(6*q)))
tolerance: 0.5%

## Winding factor: q = {q}, pitch {r}?

::: misses
- [any] $k_pk_d$.
:::
:::

::: check
given: N = 60 | 300; k = 0.88 | 0.95; P = 4 | 8; i = 3 | 30
answer: 4/pi*k*N/P*i*sqrt(2)
unit: A
tolerance: 0.5%

## Peak MMF per pole: {N} turns, $k_w$ = {k}, {P} poles, {i} A RMS?

::: misses
- [any] $\frac{4}{\pi}\frac{k_wN}{P}\sqrt{2}I$.
:::
:::
:::