S12 · Lesson 13 · Windings lab
Winding factors for any harmonic, the MMF of a real winding built up slot by slot and checked against the formula, forward and backward fields from any set of phase currents, and the harmonic content of the voltage a winding generates
Lessons 7 to 9 described windings with formulas: distribution and pitch factors, a fundamental MMF of , voltage harmonics scaled by their winding factors. In this lab you'll compute the winding factors for any layout, then build the MMF of an actual winding from its slot currents, staircase and all, and check that its fundamental matches the formula to many digits. You'll finish with the fields of unbalanced currents and the harmonics a winding passes into its voltage.
- The stems are the winding factors of a three-phase winding with 2 slots per pole per phase and the coil pitch on the slider, for harmonics 1 to 19 (odd).
- Full pitch passes the 5th and 7th; 5/6 pitch suppresses both to about 0.07.
- The 11th and 13th, at , keep the fundamental's distribution factor whatever the pitch: the slot harmonics.
Predict
A 36-slot, 4-pole, single-layer, full-pitch winding with 10 conductors per slot carries 10 A peak in phase a and −5 A in phases b and c. The formula predicts a fundamental MMF of 275 A·turns per pole. What does adding up the slot currents give?
The staircase has harmonics, but its fundamental is exactly the sum of each slot's contribution, which is what the distribution factor computes. Task 2 builds the staircase slot by slot and extracts its fundamental numerically: 274.96 A·turns against the formula's 274.96.
Name it
What the lab computes
- Winding factors: for Q slots, P poles and a coil pitch of y slots, , slot angle γ = 60°/q (electrical), pitch fraction ρ = yP/Q, and for harmonic h
- MMF from slots: in a single-layer, full-pitch winding the slots form phase belts in the order a, −c, b, −a, c, −b, each q slots wide. With Z conductors per slot and instantaneous currents, each slot carries Z times its phase's current (with the belt's sign). The MMF just past any point of the gap is the running sum of slot currents, less its mean. Its fundamental, at P/2 cycles per revolution, should be for balanced currents of peak I, with .
- Forward and backward fields: the positive- and negative-sequence currents, and , scale the forward and backward MMFs.
- Voltage harmonics: a field harmonic induces ; line-to-line voltages lose the triplen harmonics.
Check
Write winding_factor(Q, P, y, h) returning as magnitudes for harmonic h.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Write slot_mmf(Q, P, Z, ia, ib, ic, M=7200): the zero-mean MMF of a single-layer, full-pitch winding at M points around the gap (slot k centered at angle (k + ½)·2π/Q), and fundamental(F, P): the amplitude of its P/2-cycle component.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Write forward_backward(Ia, Ib, Ic): from complex phase currents, the magnitudes of the positive- and negative-sequence currents, which scale the forward and backward fields.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Write voltage_thd(B, Q, P, y): given a dict of air-gap field harmonics relative to the fundamental, {h: Bh/B1}, return the phase-voltage THD and the line-to-line THD (triplen harmonics removed) for the winding.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why can't a winding's pitch or distribution suppress its slot harmonics?
Harmonics of order have a wavelength such that adjacent slots are displaced by an angle that differs from the fundamental's by a whole multiple of 360° (electrically, for that harmonic), so the coils in a phase belt add for those harmonics exactly as they add for the fundamental, and the distribution factor is the same. The pitch factor likewise repeats, because the pitch angle for those harmonics differs from the fundamental's by a whole number of half-turns. Anything that reduced them would reduce the fundamental equally, so designers suppress slot harmonics by other means: skewing the slots, using fractional slots per pole per phase, or shaping the magnet or pole face.