S13 · Lesson 27 · Amplified links and optical noise
How amplified spontaneous emission accumulates along a chain of amplifiers, optical signal-to-noise ratio and its 58 dB rule, how span loss, noise figure and span count trade against reach, and why launch power can't simply be raised
A transoceanic cable has an amplifier every 50 to 100 km, each restoring the signal's power and each adding a little amplified spontaneous emission (lesson 26). The signal is never weaker at an amplifier's input than the span loss allows, but the noise only grows. After a hundred amplifiers, the optical signal-to-noise ratio decides whether the bits can be read. A single formula, with a constant of 58 dB, lets a designer estimate it on the back of an envelope.
- The line is the optical signal-to-noise ratio (in a 0.1 nm reference bandwidth) at the end of a chain of identical spans, against the number of spans, for the span loss on the slider, 0 dBm per channel launched and amplifiers with a 5 dB noise figure: .
- Each doubling of the span count costs 3 dB.
- Each extra decibel of span loss costs a decibel at every amplifier, which is why shorter spans reach farther.
Predict
A link has 10 spans of 80 km at 0.22 dB/km, launches 0 dBm per channel and uses amplifiers with a 5 dB noise figure. What OSNR reaches the receiver?
Each span loses 17.6 dB, so each amplifier sees −17.6 dBm. One amplifier alone would give 58 − 17.6 − 5 = 35.4 dB; ten add ten times the noise, 10 dB more: 25.4 dB. Comfortable for 10 Gb/s on-off keying; higher-order formats need more.
Name it
One amplifier's noise
An amplifier with gain G and noise figure NF adds amplified spontaneous emission at its output. Referred to its input, the noise in an optical bandwidth Δν is about . Taking the standard 0.1 nm reference bandwidth at 1550 nm (12.5 GHz), = 1.6 nW, −58 dBm, so
with the signal power at the amplifier's input.
A chain of spans
When every amplifier makes up exactly its span's loss, each sees the same input power, , and the noise of N amplifiers adds:
For unequal spans, add the noise contributions in linear units: .
The trade-offs
- Span length: span loss enters in decibels, the span count only logarithmically, so halving the spacing (losing 10 log 2 = 3 dB in count but gaining, say, 8.8 dB per span) improves OSNR.
- Launch power: raising it improves OSNR decibel for decibel until the fiber's Kerr nonlinearity (lesson 42) distorts the signal. Every link has an optimum launch power.
- Preamplifier: in a two-stage amplifier the first stage's noise figure dominates, as in Friis's formula for electronics.
Worked example
Find the OSNR of the 10-span, 80 km link at 0 dBm launch, and what it would be with 40 km spans covering the same 800 km.
Show the solution
- With 80 km spans.
- With 40 km spans. The loss per span is 8.8 dB, but there are 20 of them, which costs 13.0 dB: 5.8 dB better.
- The cost. It takes twice as many amplifiers, which is why terrestrial links use 80 to 100 km spans and submarine cables, where repairs are expensive and the distances enormous, about 50 to 70 km.
Answer the OSNR is 25.4 dB with 80 km spans and 31.2 dB with 40 km spans, 5.8 dB better.
Worked example
A system needs 18 dB of OSNR. With 100 km spans of 22 dB loss, 0 dBm launch and 5 dB noise figures, how many spans can it have?
Show the solution
- Set up the budget.
- Solve for N. so 19 spans, 1900 km.
- More launch power. Raising the launch power to 3 dBm would allow 39 spans if the fiber's nonlinearity didn't intervene; in practice the optimum launch for dense WDM on standard fiber is around 0 to 3 dBm per channel.
Answer the system can have 19 spans, 1900 km.
Worked example
One span in an otherwise uniform 10-span link (17.6 dB each, 0 dBm launch, NF 5 dB) has an extra 6 dB of loss from a repair. What does it do to the end-to-end OSNR?
Show the solution
- The normal spans. Each of the nine normal amplifiers gives an OSNR of 35.4 dB, a linear ratio of 3470.
- The lossy span. The amplifier after it gives 29.4 dB, a ratio of 871.
- Add the reciprocals.
- End-to-end OSNR. which is 24.3 dB: a single bad span costs more than a decibel of the whole link's margin.
Answer the end-to-end OSNR falls to 24.3 dB.
Check
A link of 80 identical spans of 16 dB loss launches 0 dBm per channel into amplifiers with a 7 dB noise figure.
(a)
What OSNR would one amplifier give?
(b)
What OSNR reaches the end?
Check
A system needs 18 dB of OSNR, with spans of 26 dB loss, 0 dBm launch and 6 dB noise figures.
(a)
How many spans can it have?
Check
A long link on 0.2 dB/km fiber is built with amplifier spacing reduced by a factor of 3 from 100 km.
(a)
How much less does each span lose?
(b)
How much does the end-to-end OSNR improve?
Check
A link has 9 amplifiers each giving an OSNR of 30 dB, plus one more giving 25 dB.
(a)
What is the end-to-end OSNR?
Check
An OSNR is quoted in a 0.1 nm reference bandwidth at 1310 nm.
(a)
What is that bandwidth in frequency?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
(b)
What constant replaces 58 dB in the OSNR formula?
Check
Why can't a long-haul link's OSNR be raised indefinitely by launching more power?
Check
A chain of N spans of loss L dB with launch power P dBm and noise figure F dB.
Step 1
What power reaches each amplifier, in dBm?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What end-to-end OSNR results?
Check
Write chain_osnr(launch_dbm, span_losses_db, nf_db): the end-to-end OSNR in dB of a chain where each amplifier exactly restores the launch power after its span, adding the amplifiers' noise in linear units.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why does halving the amplifier spacing improve a link's OSNR even though it doubles the number of noisy amplifiers?
Each amplifier's added noise is fixed by its noise figure, so the OSNR it delivers depends on the signal power arriving at its input. Span loss in decibels grows linearly with span length, so halving the spacing raises every amplifier's input power by half the span loss, typically 8 to 10 dB. Doubling the number of amplifiers only doubles the total noise, a 3 dB penalty. The gain in input power outweighs the extra noise, until amplifiers become so closely spaced that their cost, and not the OSNR, is the limit.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.