S13 · Lesson 31 · Coherent detection and lidar
Mixing a weak signal with a strong local oscillator on a photodiode, the beat note and its shot-noise-limited signal-to-noise ratio, heterodyne and homodyne detection, and coherent and FMCW lidar's range resolution and Doppler measurement
A photodiode measures power, so it throws away the light's phase and frequency. Add a strong, steady laser beam, the local oscillator, to the weak signal before the detector, and the photocurrent picks up a beat at their difference frequency whose amplitude grows with the oscillator's strength. The signal now rides far above the receiver's thermal noise, and its phase and frequency are recovered. Coherent detection lets long-haul links use QPSK and QAM, and lets lidars measure distance and velocity at once.
- The curve is a heterodyne receiver's signal-to-noise ratio against the received signal power, for a 1550 nm signal, a detector of quantum efficiency 0.8 and the detection bandwidth on the slider, in the shot-noise limit: SNR = .
- A nanowatt over 1 GHz gives about 8 dB; the SNR rises one decibel for each decibel of signal.
- The dashed line is a direct-detection receiver with the same detector and 1.8 µA of thermal noise current (a 50 Ω load over 10 GHz, as in lesson 36's example), whose SNR falls twice as fast because it goes as the square of the signal.
Predict
A 1 nW signal at 1550 nm is detected coherently with a strong local oscillator over 1 GHz, using a detector of quantum efficiency 0.8. What signal-to-noise ratio can the receiver reach?
With a strong local oscillator the only noise left is the oscillator's own shot noise, and the SNR becomes , 8 dB: about six signal photons per detection interval. Direct detection of a nanowatt would be buried hundreds of times below a typical thermal noise floor.
Name it
Mixing on a photodiode
A signal of power and a local oscillator , matched in polarization, on a detector of responsivity produce
with the intermediate frequency and φ the phase difference. The beat's amplitude grows with , lifting the weak signal above thermal noise.
Heterodyne and homodyne
- Heterodyne (): the signal moves to an intermediate frequency where electronics recover its amplitude, phase and frequency. With a strong oscillator the noise is its shot noise, and
- Homodyne ( = 0, phase-locked): 3 dB better for a single quadrature. Modern coherent receivers use a 90° optical hybrid and balanced detectors to recover both quadratures at once, with digital phase tracking replacing the phase lock.
Lidar
- Pulsed time of flight: range = , resolution for pulse width τ.
- FMCW: a chirp of bandwidth B over time T, mixed with its echo from range R, beats at , and the range resolution is : 1 GHz gives 15 cm.
- Doppler: a target moving at radial speed v shifts the echo by , which a coherent receiver measures directly: 38.7 MHz at 30 m/s and 1550 nm.
The laser's coherence length (lesson 29) must exceed twice the range for the echo to beat cleanly with the oscillator.
Worked example
A 1550 nm heterodyne receiver with η = 0.8 and 1 GHz of bandwidth receives 1 nW. Find its shot-noise-limited SNR, and the local oscillator power needed to beat a 1.8 µA thermal noise current by 10 dB.
Show the solution
- Shot-noise-limited SNR. or 8.0 dB.
- Noise current to reach. The oscillator's shot noise must beat the 1.8 µA thermal noise by 10 dB:
- Oscillator power. Its shot noise is with = 1.0 A/W, so
- In practice. That's an uncomfortably large oscillator, so practical receivers balance their detectors and use low-noise amplifiers to need only a few milliwatts.
Answer the shot-noise-limited SNR is 6.24 (8.0 dB), and beating the thermal noise by 10 dB takes a 0.1 W local oscillator.
Worked example
An FMCW lidar sweeps 1 GHz in 10 µs at 1550 nm. Find its range resolution, the beat frequency from a target 100 m away, and the Doppler shift if the target approaches at 30 m/s.
Show the solution
- Range resolution.
- Beat frequency from 100 m.
- Doppler shift.
- Separating range and speed. The shift moves the beat up on the falling half of a triangular chirp and down on the rising half; averaging the two gives range, differencing them gives speed.
Answer the range resolution is 15 cm, the beat from 100 m is 66.7 MHz, and the Doppler shift is 38.7 MHz.
Worked example
A pulsed lidar uses 5 ns pulses. What range resolution does it have, and how long must it wait for an echo from 300 m?
Show the solution
- Range resolution.
- Echo delay. so it can fire at most 500 000 pulses a second without ambiguity.
- The trade-off. Shorter pulses improve resolution but need more detection bandwidth, which brings more noise; FMCW gets fine resolution with a low-bandwidth detector by spreading the sweep in time.
Answer the resolution is 0.75 m, and an echo from 300 m takes 2.0 µs to return.
Check
A shot-noise-limited heterodyne receiver at 1550 nm (η = 0.6) detects 1 nW over 10 GHz.
(a)
What is its signal-to-noise ratio (linear)?
(b)
What would homodyne detection of one quadrature give, in dB?
Check
An FMCW lidar sweeps 1 GHz in 1 µs and sees a target at 1000 m.
(a)
What is its range resolution?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
(b)
At what frequency does the echo beat?
Check
A target approaches a coherent lidar at 30 m/s; the lidar works at 905 nm.
(a)
What Doppler shift does the echo carry?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
Check
A pulsed lidar uses 5 ns pulses to reach targets up to 50 m.
(a)
What is its range resolution?
Write units the way you normally would: 1.5 m, 1500 mm and 0.0015 km are the same answer.
(b)
What is the highest pulse rate without range ambiguity?
Check
A 10 nW signal and a 1 mW local oscillator fall on a detector of 1 A/W.
(a)
What is the beat note's peak amplitude?
Write units the way you normally would: 1.5 µA, 1500 nA and 0.0015 mA are the same answer.
Check
Why does a strong local oscillator make a coherent receiver shot-noise limited, however noisy its electronics?
Check
A heterodyne receiver (η = e, wavelength l, bandwidth B) detects power P; separately, an FMCW lidar sweeps W hertz in T seconds to a target at R meters.
Step 1
What is the receiver's shot-noise-limited SNR?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What beat frequency does the lidar see?
Check
Write fmcw_beat(R, B, T, v, lam, up): the beat frequency of an FMCW lidar (sweep B over T) for a target at range R approaching at speed v, on the rising (up = True) or falling half of a triangular chirp (the Doppler shift lowers the rising-half beat and raises the falling-half one); and range_speed(f_up, f_down, B, T, lam): recover (R, v) from the two beats.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
How does an FMCW lidar measure distance with a slow photodetector, when a pulsed lidar with the same resolution needs a fast one?
A pulsed lidar measures the echo's delay directly, so its resolution is set by how short a pulse the detector can follow. An FMCW lidar instead sweeps its laser's frequency linearly in time and mixes the returning echo with the light it's sending at that moment. Because the echo left earlier, it's at a slightly different frequency, and the difference is proportional to the delay, so range becomes a beat frequency of megahertz that slow electronics can measure precisely. The resolution comes from the total swept bandwidth, not from the detector's speed, and the coherent mixing also measures the target's velocity from its Doppler shift.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.