S13 · Lesson 46 · Optical fiber communication links
Power budgets in decibels, loss-limited and dispersion-limited reach for broad and narrow sources, the Q factor and bit error rate, wavelength-division multiplexing on the ITU grid, and how amplifiers and coherent detection extend a link
A fiber link is a chain of everything in this course: a laser diode or modulator, fiber with its loss, dispersion and nonlinearity, amplifiers, and a photodetector with its noise. Designing one means checking two budgets. The power budget asks whether enough light arrives for the receiver to decide each bit correctly; the dispersion budget asks whether the bits are still distinct when they get there. Whichever runs out first sets the reach.
- The reach of a single-span link against bit rate: the loss limit (flat, set by the power budget) and the dispersion limit for a narrow-linewidth source, (falling as ).
- At low bit rates, loss limits the reach; at high bit rates, dispersion takes over, which is why 10 Gb/s and faster links need dispersion compensation or coherent detection.
- Adjust the budget and the fiber's dispersion.
Predict
A link launches 0 dBm into fiber losing 0.2 dB/km, with 1 dB of connectors and a 3 dB margin, and the receiver needs −28 dBm. How long can it be?
The budget is 0 − (−28) = 28 dB. Take off 3 dB of margin and 1 dB for connectors, leaving 24 dB for fiber: 24/0.2 = 120 km. Decibels make the budget a subtraction.
Name it
The power budget
In dBm (decibels above 1 mW), the received power is the launched power minus every loss:
and it must exceed the receiver's sensitivity plus a margin.
The dispersion budget
- Broad source (spectral width Δλ larger than the modulation): pulses spread by ; keep it under a quarter of a bit: .
- Narrow source (externally modulated laser): the modulation's own bandwidth spreads; a common criterion is , so .
Q and bit error rate
With Gaussian noise on the ones and zeros, the error rate at the optimum threshold depends on the Q factor (the separation of the levels over the sum of their noise standard deviations):
Q = 6 gives 10⁻⁹; Q = 7 gives about 10⁻¹².
Wavelength-division multiplexing
Many channels share one fiber at different wavelengths, on the ITU grid (100, 50 or finer GHz spacing around 193.1 THz). The erbium C band, 1530 to 1565 nm, spans about 4.4 THz. Amplifiers boost every channel at once, and coherent receivers with digital signal processing undo dispersion electronically, which together let one fiber carry tens of terabits per second across oceans.
Worked example
How far can 10 Gb/s and 40 Gb/s externally modulated signals go on standard fiber (|β₂| = 21.7 ps²/km) before dispersion limits them? And a 1 Gb/s signal from a laser with 1 nm of spectral width (D = 17)?
Show the solution
- 10 Gb/s.
- 40 Gb/s. Four times the bit rate goes 16 times less far, 1.8 km.
- The broad source at 1 Gb/s. With D = 17 ps/(nm·km) and 1 nm,
- Compare. That's worse than the narrow source at ten times the bit rate: source linewidth matters as much as bit rate.
Answer 28.8 km at 10 Gb/s, 1.8 km at 40 Gb/s, and 14.7 km for the broad source at 1 Gb/s.
Worked example
How many 50 GHz channels fit in the C band, and what error rate does Q = 7 give?
Show the solution
- Width of the C band.
- Channel count. At 50 GHz that's about 87 channels (the standard grid allots 88 or 96 by extending the edges).
- Error rate at Q = 7.
Answer about 87 channels of 50 GHz fit in the C band, and Q = 7 gives an error rate of 1.3 × 10⁻¹².
Worked example
A 0 dBm transmitter feeds 80 km of 0.22 dB/km fiber with four 0.5 dB connectors and a 1 dB dispersion penalty, into a receiver that needs −28 dBm. What margin does the link have?
Show the solution
- Losses. The fiber takes 17.6 dB, the connectors 2 dB and the penalty 1 dB.
- Received power.
- Margin. above the receiver's sensitivity.
- Is that enough? Designers usually want 3 to 6 dB of margin for aging, repairs and temperature, so this link has room for a few more splices or about 15 km more fiber.
Answer the link has 7.4 dB of margin.
Check
A link launches 0 dBm; the receiver needs −35 dBm; allow a 6 dB margin and 2 dB of connectors on fiber losing 0.2 dB/km. What's the longest span?
Write units the way you normally would: 1.5 km and 1500 m are the same answer.
Check
0 dBm is launched into 20 km of fiber losing 0.35 dB/km, with 3 dB of connectors. What arrives?
Check
A 1 Gb/s link uses a source 3 nm wide over fiber with |D| = 3 ps/(nm·km). What's its dispersion-limited reach?
Write units the way you normally would: 1.5 km and 1500 m are the same answer.
Check
An externally modulated 10 Gb/s signal crosses fiber with |β₂| = 5 ps²/km. What's its dispersion-limited reach?
Write units the way you normally would: 1.5 km and 1500 m are the same answer.
Check
A receiver's Q factor is 5. What's its bit error rate?
Check
How many channels spaced 100 GHz fit between 1530 nm and 1580 nm?
Check
A transmitter launches 0 dBm into 120 km of 0.2 dB/km fiber with 6 connectors of 0.5 dB, toward a receiver needing −28 dBm.
(a)
What power arrives?
(b)
What margin is left?
Check
A link runs at B bits per second on fiber with |β₂| = b s²/m and |D| = D s/m² (so that |D| times a length in meters and a width in meters gives seconds).
Step 1
How long can it be with a narrow, externally modulated source, in meters?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
And with a source of spectral width w meters?
Explain why
Why is reach limited by loss at low bit rates and by dispersion at high ones?
The power budget depends only weakly on bit rate: a receiver needs a certain number of photons per bit, so its sensitivity in watts rises in proportion to bit rate, a modest effect in decibels. The fiber's loss is fixed per kilometer, so the loss-limited reach is nearly constant. Dispersion is different: a faster signal has shorter bits and a wider spectrum, so it spreads faster in time and has less time to spare; for a narrow source the tolerable length falls as the square of the bit rate. At low rates the dispersion limit is thousands of kilometers, far beyond the loss limit; at 10 Gb/s and above it drops below it, so dispersion sets the reach unless compensated.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.