S138 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S13 · Lesson 8 · Imaging, resolution and spatial filtering

The 4f system and filtering in the Fourier plane, coherent imaging's sharp frequency cutoff at NA/λ, incoherent imaging's modulation transfer function reaching 2NA/λ, Rayleigh and Abbe resolution, depth of field, lithography's half-pitch, and cleaning a laser beam with a pinhole

Lesson 4 showed that a lens puts an object's spatial-frequency spectrum in its back focal plane. Put a second lens after it and the spectrum is transformed back into an image. Everything that happens in between, a finite aperture cutting off high frequencies, a deliberate mask blocking some, decides what the image contains. That's why every imaging system, from a phone camera to the lithography scanners that print chips, has a resolution set by its numerical aperture and wavelength, and why they're designed in frequency terms.

  • The transfer functions of a diffraction-limited imaging system with a circular pupil of numerical aperture NA at wavelength λ, against spatial frequency in the object.
  • Coherent illumination passes every frequency up to NA/λ with full contrast, and nothing above.
  • Incoherent illumination passes frequencies up to twice that, 2NA/λ, but with contrast falling steadily: the modulation transfer function (MTF).

Predict

A microscope objective has NA = 0.9 and images in 550 nm light. Roughly what's the smallest separation at which two point sources can still be told apart?

Name it

The 4f system

Lens 1 (focal length f1) transforms the object; at its back focal plane, a distance f1 further on, lies the spectrum; lens 2 (f2) transforms it back to an image of magnification −f2/f1. A mask in the Fourier plane filters the spectrum: a pinhole passes only low frequencies (blurring), a central stop blocks them (edges only, dark-field), a slit passes one direction.

Coherent imaging

The pupil of numerical aperture NA passes object spatial frequencies up to the coherent cutoff νc=NA/λ, with no attenuation below it. The system is linear in field amplitude.

Incoherent imaging

With incoherent light the system is linear in intensity, and its transfer function, the optical transfer function, is the pupil's autocorrelation. For a circular pupil the MTF reaches zero at 2NA/λ:

MTF(ν)=2π[cos−1⁡u−u1−u2],u=νλ2NA

Resolution and depth

  • Rayleigh: two points resolved at 0.61λ/NA.
  • Abbe: the finest grating period imaged is λ/(2NA) (with oblique illumination).
  • Depth of field: about ±λ/(2NA2), so λ/NA2 in all.
  • Lithography: printed half-pitch k1λ/NA, with k1 down to about 0.25 using every resolution-enhancement trick.

Spatial filtering a laser

Focusing a beam onto a pinhole about 1.5 times the focused spot's diameter passes the clean Gaussian and blocks the high-frequency speckle and scatter that ride on it.

Worked example

Compare the 0.9 NA microscope at 550 nm in coherent and incoherent light.

Show the solution
  1. Coherent cutoff. NAλ=0.9550nm=1636lines/mm a period of 611 nm.
  2. Incoherent cutoff. It's twice as high, 3273 lines/mm, but with falling contrast: at half that frequency the MTF is 0.39.
  3. Rayleigh resolution. 0.61×550nm0.9=373nm
  4. Depth of field. DOF≈550nm0.81=679nm

Answer the cutoff is 1636 lines/mm in coherent light and 3273 lines/mm in incoherent light (with an MTF of 0.39 at half that); the Rayleigh resolution is 373 nm and the depth of field about 679 nm.

Worked example

What half-pitch can a 193 nm immersion scanner with NA 1.35 print at k1 = 0.25? And what pinhole cleans a 1 mm, 633 nm beam focused by a 20 mm lens?

Show the solution
  1. Half-pitch. HP=k1λNA=0.25×193nm1.35=35.7nm Smaller features need multiple patterning or 13.5 nm extreme ultraviolet.
  2. Focused spot. w=λfπw0=4.03μm in radius, 8.06 µm in diameter.
  3. Pinhole size. A pinhole of about 12 µm passes the beam and blocks the rest.

Answer the scanner prints a 35.7 nm half-pitch, and a pinhole of about 12 µm cleans the beam.

Worked example

A 10× microscope objective has NA 0.25 and is used at 550 nm. Find its Rayleigh resolution, depth of field and cutoffs, and say whether it can show a grating of 2 µm period.

Show the solution
  1. Rayleigh resolution. r=0.61×550nm0.25=1.34μm
  2. Depth of field. DOF≈λNA2=8.8μm
  3. Coherent cutoff. NAλ=455lines/mm a period of 2.2 µm, so with coherent on-axis light the 2 µm grating (500 lines/mm) vanishes from the image.
  4. Incoherent cutoff. It doubles to 909 lines/mm, and the grating appears, at reduced contrast.
  5. In practice. Condenser settings that fill the objective's aperture show finer detail.

Answer 1.34 µm resolution, about 8.8 µm depth of field, and cutoffs of 455 lines/mm (coherent) and 909 lines/mm (incoherent); the 2 µm grating shows only in incoherent light, at reduced contrast.

Check

A diffraction-limited system with NA = 0.25 images at 550 nm. What's its Rayleigh resolution?

Write units the way you normally would: 1.5 nm, 1500 pm and 0.0015 µm are the same answer.

Check

What's the coherent cutoff frequency of a system with NA = 0.25 at 550 nm?

Check

What's the highest spatial frequency an incoherent system with NA = 0.25 at 550 nm can image at all?

Check

A lithography tool at 13.5 nm with NA 1.35 runs at k1 = 0.3. What half-pitch does it print?

Write units the way you normally would: 1.5 nm, 1500 pm and 0.0015 µm are the same answer.

Check

At 0.5 of the incoherent cutoff frequency, what's a circular pupil's MTF?

Check

About how deep is the depth of field of a system with NA = 0.25 at 550 nm?

Write units the way you normally would: 1.5 nm, 1500 pm and 0.0015 µm are the same answer.

Check

An imaging system has NA 0.5 at 405 nm.

(a)

What is its Rayleigh resolution?

Write units the way you normally would: 1.5 nm, 1500 pm and 0.0015 µm are the same answer.

(b)

What is its coherent cutoff frequency?

(c)

About how deep is its field?

Check

An incoherent system has NA N at wavelength l (mm); consider spatial frequency v (lines/mm) below its cutoff.

Step 1

What is the normalized frequency u?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why can incoherent imaging resolve finer detail than coherent imaging with the same lens?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.