title: Imaging, resolution and spatial filtering
heading: The 4f system and filtering in the Fourier plane, coherent imaging's sharp frequency cutoff at NA/λ, incoherent imaging's modulation transfer function reaching 2NA/λ, Rayleigh and Abbe resolution, depth of field, lithography's half-pitch, and cleaning a laser beam with a pinhole
eyebrow: S13 · Lesson 8 · Imaging, resolution and spatial filtering
xp: 50
---

::: hook
Lesson 4 showed that a lens puts an object's spatial-frequency spectrum in its back focal plane. Put a second lens after it and the spectrum is transformed back into an image. Everything that happens in between, a finite aperture cutting off high frequencies, a deliberate mask blocking some, decides what the image contains. That's why every imaging system, from a phone camera to the lithography scanners that print chips, has a resolution set by its numerical aperture and wavelength, and why they're designed in frequency terms.
:::

::: play
- The transfer functions of a diffraction-limited imaging system with a circular pupil of numerical aperture NA at wavelength λ, against spatial frequency in the object.
- Coherent illumination passes every frequency up to $\text{NA}/\lambda$ with full contrast, and nothing above.
- Incoherent illumination passes frequencies up to twice that, $2\text{NA}/\lambda$, but with contrast falling steadily: the modulation transfer function (MTF).
:::

```sim plot
view: graph
x: v = 0..4000 mm^-1
y: m = 0..1.05
slider: a = 0.1..1.4 step 0.05 = 0.9
slider: l = 193..1000 step 1 = 550 nm
plot: step(a/(l*1e-6) - v) | samples: 600 | label: coherent
plot: 2/pi*(acos((v/(2*a/(l*1e-6)) + 1 - abs(v/(2*a/(l*1e-6)) - 1))/2) - (v/(2*a/(l*1e-6)) + 1 - abs(v/(2*a/(l*1e-6)) - 1))/2*sqrt(1 - ((v/(2*a/(l*1e-6)) + 1 - abs(v/(2*a/(l*1e-6)) - 1))/2)^2)) | samples: 600 | color: ch3 | label: incoherent MTF
readout: coherent cutoff, lines/mm = a/(l*1e-6) | digits: 4
readout: Rayleigh resolution, nm = 0.61*l/a | digits: 4
```

::: predict
## A microscope objective has NA = 0.9 and images in 550 nm light. Roughly what's the smallest separation at which two point sources can still be told apart?

- [ ] 55 nm
- [x] About 370 nm
- [ ] About 1 µm
- [ ] 550 nm exactly

::: reveal
Each point images to an Airy pattern whose first zero is at $0.61\lambda/\text{NA}$ in the object plane. By Rayleigh's criterion two points are resolved when one's peak sits on the other's first zero: 0.61 × 550/0.9 = 373 nm. Finer detail needs a shorter wavelength, a larger NA, or tricks like structured illumination.
:::
:::

::: nameit
## The 4f system

Lens 1 (focal length $f_1$) transforms the object; at its back focal plane, a distance $f_1$ further on, lies the spectrum; lens 2 ($f_2$) transforms it back to an image of magnification $-f_2/f_1$. A mask in the Fourier plane filters the spectrum: a pinhole passes only low frequencies (blurring), a central stop blocks them (edges only, dark-field), a slit passes one direction.

## Coherent imaging

The pupil of numerical aperture NA passes object spatial frequencies up to the **coherent cutoff** $\nu_c = \text{NA}/\lambda$, with no attenuation below it. The system is linear in field amplitude.

## Incoherent imaging

With incoherent light the system is linear in intensity, and its transfer function, the **optical transfer function**, is the pupil's autocorrelation. For a circular pupil the MTF reaches zero at $2\text{NA}/\lambda$:

$$\text{MTF}(\nu) = \frac{2}{\pi}\left[\cos^{-1}u - u\sqrt{1 - u^2}\right], \qquad u = \frac{\nu\lambda}{2\,\text{NA}}$$

## Resolution and depth

- **Rayleigh:** two points resolved at $0.61\lambda/\text{NA}$.
- **Abbe:** the finest grating period imaged is $\lambda/(2\text{NA})$ (with oblique illumination).
- **Depth of field:** about $\pm\lambda/(2\,\text{NA}^2)$, so $\lambda/\text{NA}^2$ in all.
- **Lithography:** printed half-pitch $k_1\lambda/\text{NA}$, with $k_1$ down to about 0.25 using every resolution-enhancement trick.

## Spatial filtering a laser

Focusing a beam onto a pinhole about 1.5 times the focused spot's diameter passes the clean Gaussian and blocks the high-frequency speckle and scatter that ride on it.
:::

::: example
## Compare the 0.9 NA microscope at 550 nm in coherent and incoherent light.

::: solution
1. **Coherent cutoff.**
   $$\begin{aligned} \frac{\text{NA}}{\lambda} &= \frac{0.9}{550\ \text{nm}} \\ &= 1636\ \text{lines/mm} \end{aligned}$$
   a period of 611 nm.
2. **Incoherent cutoff.** It's twice as high, 3273 lines/mm, but with falling contrast: at half that frequency the MTF is 0.39.
3. **Rayleigh resolution.**
   $$\frac{0.61 \times 550\ \text{nm}}{0.9} = 373\ \text{nm}$$
4. **Depth of field.**
   $$\begin{aligned} \text{DOF} &\approx \frac{550\ \text{nm}}{0.81} \\ &= 679\ \text{nm} \end{aligned}$$

**Answer:** the cutoff is 1636 lines/mm in coherent light and 3273 lines/mm in incoherent light (with an MTF of 0.39 at half that); the Rayleigh resolution is 373 nm and the depth of field about 679 nm.
:::
:::

::: example
## What half-pitch can a 193 nm immersion scanner with NA 1.35 print at $k_1$ = 0.25? And what pinhole cleans a 1 mm, 633 nm beam focused by a 20 mm lens?

::: solution
1. **Half-pitch.**
   $$\begin{aligned} \text{HP} &= \frac{k_1\lambda}{\text{NA}} \\ &= \frac{0.25 \times 193\ \text{nm}}{1.35} \\ &= 35.7\ \text{nm} \end{aligned}$$
   Smaller features need multiple patterning or 13.5 nm extreme ultraviolet.
2. **Focused spot.**
   $$\begin{aligned} w &= \frac{\lambda f}{\pi w_0} \\ &= 4.03\ \mu\text{m} \end{aligned}$$
   in radius, 8.06 µm in diameter.
3. **Pinhole size.** A pinhole of about 12 µm passes the beam and blocks the rest.

**Answer:** the scanner prints a 35.7 nm half-pitch, and a pinhole of about 12 µm cleans the beam.
:::
:::

::: example
## A 10× microscope objective has NA 0.25 and is used at 550 nm. Find its Rayleigh resolution, depth of field and cutoffs, and say whether it can show a grating of 2 µm period.

::: solution
1. **Rayleigh resolution.**
   $$\begin{aligned} r &= \frac{0.61 \times 550\ \text{nm}}{0.25} \\ &= 1.34\ \mu\text{m} \end{aligned}$$
2. **Depth of field.**
   $$\begin{aligned} \text{DOF} &\approx \frac{\lambda}{\text{NA}^2} \\ &= 8.8\ \mu\text{m} \end{aligned}$$
3. **Coherent cutoff.**
   $$\frac{\text{NA}}{\lambda} = 455\ \text{lines/mm}$$
   a period of 2.2 µm, so with coherent on-axis light the 2 µm grating (500 lines/mm) vanishes from the image.
4. **Incoherent cutoff.** It doubles to 909 lines/mm, and the grating appears, at reduced contrast.
5. **In practice.** Condenser settings that fill the objective's aperture show finer detail.

**Answer:** 1.34 µm resolution, about 8.8 µm depth of field, and cutoffs of 455 lines/mm (coherent) and 909 lines/mm (incoherent); the 2 µm grating shows only in incoherent light, at reduced contrast.
:::
:::

::: check
given: l = 405 | 550 | 1064; a = 0.25 | 0.65 | 1.4
answer: 0.61*l/a
unit: nm
tolerance: 0.5%

## A diffraction-limited system with NA = {a} images at {l} nm. What's its Rayleigh resolution?

::: right
Right. $0.61\lambda/\text{NA}$ = {answer} nm.
:::

::: misses
- [1.22*l/a] With NA defined as the half-angle's sine, Rayleigh's limit is $0.61\lambda/\text{NA}$.
- [any] Not yet. The Airy pattern's first zero in object space.
:::
:::

::: check
given: l = 405 | 550 | 1064; a = 0.25 | 0.65 | 1.4
answer: a/(l*1e-6)
unit: mm^-1
tolerance: 0.5%

## What's the coherent cutoff frequency of a system with NA = {a} at {l} nm?

::: right
Right. $\text{NA}/\lambda$ = {answer} lines/mm.
:::

::: misses
- [2*a/(l*1e-6)] That's the incoherent cutoff.
- [any] Not yet. The pupil's edge in frequency.
:::
:::

::: check
given: l = 405 | 550 | 1064; a = 0.25 | 0.65 | 1.4
answer: 2*a/(l*1e-6)
unit: mm^-1
tolerance: 0.5%

## What's the highest spatial frequency an incoherent system with NA = {a} at {l} nm can image at all?

::: right
Right. $2\text{NA}/\lambda$ = {answer} lines/mm.
:::

::: misses
- [a/(l*1e-6)] Incoherent imaging reaches twice the coherent cutoff.
- [any] Not yet. The pupil's autocorrelation is twice as wide.
:::
:::

::: check
given: k = 0.25 | 0.3 | 0.4; l = 13.5 | 193 | 248; a = 0.33 | 0.93 | 1.35
answer: k*l/a
unit: nm
tolerance: 0.5%

## A lithography tool at {l} nm with NA {a} runs at $k_1$ = {k}. What half-pitch does it print?

::: right
Right. $k_1\lambda/\text{NA}$ = {answer} nm.
:::

::: misses
- [any] Not yet. $k_1\lambda/\text{NA}$.
:::
:::

::: check
given: u = 0.2 | 0.5 | 0.8
answer: 2/pi*(acos(u) - u*sqrt(1 - u^2))
tolerance: 0.5%

## At {u} of the incoherent cutoff frequency, what's a circular pupil's MTF?

::: right
Right. $\frac{2}{\pi}[\cos^{-1}u - u\sqrt{1 - u^2}]$ = {answer}.
:::

::: misses
- [1 - u] The MTF isn't a straight line.
- [any] Not yet. The overlap area of two shifted circles.
:::
:::

::: check
given: l = 405 | 550 | 1064; a = 0.25 | 0.65 | 1.4
answer: l/a^2
unit: nm
tolerance: 0.5%

## About how deep is the depth of field of a system with NA = {a} at {l} nm?

::: right
Right. $\lambda/\text{NA}^2$ = {answer} nm in all.
:::

::: misses
- [l/a] Depth goes as $1/\text{NA}^2$.
- [any] Not yet. $\pm\lambda/(2\text{NA}^2)$.
:::
:::

::: check
kind: parts
given: N = 0.1 | 0.5 | 0.95; l = 405 | 550 | 633

## An imaging system has NA {N} at {l} nm.

::: part
answer: 0.61*l/N
unit: nm
tolerance: 0.5%

### What is its Rayleigh resolution?

::: misses
- [l/(2*N)] That's the Abbe limit for a grating.
- [any] $0.61\lambda/\text{NA}$.
:::
:::

::: part
answer: N/(l*1e-6)
unit: lines/mm
tolerance: 0.5%

### What is its coherent cutoff frequency?

::: misses
- [2*N/(l*1e-6)] That's the incoherent cutoff.
- [any] $\text{NA}/\lambda$.
:::
:::

::: part
answer: l/N^2/1e3
unit: µm
tolerance: 0.5%

### About how deep is its field?

::: misses
- [any] $\lambda/\text{NA}^2$.
:::
:::
:::

::: check
kind: derivation
vars: v = 1..3000, l = 0.0002..0.002, N = 0.05..1.4

## An incoherent system has NA N at wavelength l (mm); consider spatial frequency v (lines/mm) below its cutoff.

::: step
answer: v*l/(2*N)

### What is the normalized frequency u?
:::

::: step
answer: 2/pi*(acos(v*l/(2*N)) - v*l/(2*N)*sqrt(1 - (v*l/(2*N))^2))

### What is the MTF there?
:::

::: right
Right. The MTF falls smoothly from 1 to zero at $2\text{NA}/\lambda$.
:::
:::

::: explain
## Why can incoherent imaging resolve finer detail than coherent imaging with the same lens?

::: model
In coherent illumination every point of the object radiates in step, the system is linear in field, and a spatial frequency reaches the image only if its diffracted wave fits through the pupil: frequencies above NA/λ are simply lost. In incoherent illumination the points are independent and the system is linear in intensity. An intensity pattern of a given frequency arises from pairs of field components whose frequencies differ by that amount, and those pairs can sit on opposite edges of the pupil, so intensity frequencies up to twice the coherent cutoff get through. They come through with reduced contrast, since fewer pairs span such wide separations, which is what the falling MTF describes.
:::
:::

::: practice

::: check
given: l = 300 | 1100; a = 0.1 | 1.3
answer: 0.61*l/a
unit: nm
tolerance: 0.5%

## Rayleigh resolution: {l} nm, NA {a}?

::: misses
- [any] $0.61\lambda/\text{NA}$.
:::
:::

::: check
given: l = 300 | 1100; a = 0.1 | 1.3
answer: a/(l*1e-6)
unit: mm^-1
tolerance: 0.5%

## Coherent cutoff: {l} nm, NA {a}?

::: misses
- [any] $\text{NA}/\lambda$.
:::
:::

::: check
given: u = 0.1 | 0.25 | 0.4 | 0.5 | 0.75 | 0.9
answer: 2/pi*(acos(u) - u*sqrt(1 - u^2))
tolerance: 0.5%

## MTF at {u} of cutoff?

::: misses
- [any] The circular-pupil MTF.
:::
:::
:::