S1326 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S13 · Lesson 26 · Laser amplifiers

Pumping to inversion, small-signal gain, gain saturation and the saturation intensity, the large-signal gain of a homogeneously broadened amplifier and its 3 dB compression point, the erbium-doped fiber amplifier, quantum-defect efficiency, and the noise figure set by spontaneous emission

Before 1990 every few tens of kilometers of fiber needed a repeater that detected the light, cleaned up the electrical signal and sent it again. The erbium-doped fiber amplifier changed that: a few meters of doped fiber, pumped by a semiconductor laser, amplifies every wavelength channel at once, by a factor of a thousand, directly as light. Its behavior comes down to how gain falls as the signal grows strong enough to use up the inversion, and to the noise that spontaneous emission inevitably adds.

  • A homogeneously broadened amplifier with small-signal gain G0 and saturation power Psat: the input power at which the gain has dropped to G, from ln⁡(G0/G)=(G−1)Pin/Psat (both axes logarithmic, in dB and dBm).
  • For weak inputs the gain stays at G0; around Psat/G0 at the input, it begins to compress.
  • A strong signal leaves less inversion for itself: output power grows more slowly than input, approaching a ceiling set by the pump.

Predict

An amplifier has 30 dB of small-signal gain and a 10 mW saturation power. What's its gain for a 100 µW input?

Name it

Small-signal gain

A pumped medium with gain coefficient γ0 over length L amplifies weak signals by G0=eγ0L, or 4.343γ0L dB.

Saturation

Stimulated emission by the signal drains the inversion. For a homogeneously broadened medium,

γ=γ01+I/Isat,Isat=hνστ

with τ the upper level's lifetime. Integrating through the amplifier, with Psat=IsatA,

ln⁡G0G=(G−1)PinPsat

The gain falls to half (3 dB compression) at an output power of Psatln⁡2G0G0−2.

The erbium-doped fiber amplifier

Er³⁺ in silica, pumped at 980 or 1480 nm, amplifies across 1530 to 1565 nm (the C band). Its long lifetime (about 10 ms) means saturation responds only to average power, so it doesn't distort fast data. Signal photons can never outnumber pump photons, so the power conversion efficiency is at most the quantum defect ratio λp/λs.

Noise

Spontaneous emission amplified along the fiber (ASE) adds noise. At high gain the noise figure is F≈2nsp, with nsp=N2/(N2−N1)≥1: at least 3 dB, the quantum limit for a phase-insensitive amplifier.

Worked example

Find the saturation intensities of Nd:YAG (σ = 2.8 × 10⁻¹⁹ cm², τ = 230 µs, 1064 nm) and erbium (σ ≈ 7 × 10⁻²¹ cm², τ = 10 ms, 1550 nm).

Show the solution
  1. Nd:YAG. Is=hνστ=1.87×10−19J2.8×10−23m2×230μs=2.9kW/cm2
  2. Erbium. Is=1.28×10−19J7×10−25m2×10ms=1.8kW/cm2
  3. In a fiber core. In a core of 50 µm² that's about 1 mW for erbium, which is why EDFAs saturate at milliwatt powers.

Answer the saturation intensity is 2.9 kW/cm² for Nd:YAG and 1.8 kW/cm² for erbium.

Worked example

For the 30 dB, 10 mW amplifier, where is the 3 dB compression point? And what's the best efficiency of a 980 nm pumped EDFA at 1550 nm?

Show the solution
  1. Output at 3 dB compression. There the gain has fallen from 1000 to 500, so Pout=Psatln⁡2×1000998=6.95mW from an input of 13.9 µW.
  2. Quantum defect. 9801550=0.632 so at most 63% of pump power becomes signal.
  3. Pumping at 1480 nm. It raises the limit to 95%, at the cost of a noisier, less complete inversion.

Answer the 3 dB compression point is at 6.95 mW of output (13.9 µW in), and a 980 nm pumped EDFA can turn at most 63% of its pump power into signal.

Worked example

The 30 dB amplifier with Psat = 10 mW receives 100 µW. How much gain does it actually give, and what comes out?

Show the solution
  1. The saturated gain equation. ln⁡1000G=(G−1)×100μW10mW
  2. Solve it. Bisection gives G = 175, or 22.4 dB.
  3. Output. 175×100μW=17.5mW rather than the 100 mW the small-signal gain would promise.
  4. Why links run saturated. Saturation trades gain for output power: EDFAs in long-haul links run deep in saturation on purpose, which makes their output nearly independent of input and keeps a chain of them stable.

Answer the amplifier gives a gain of 175 (22.4 dB), and 17.5 mW comes out.

Check

A transition at 1.064 µm has cross section 0.5 × 10⁻¹⁹ cm² and lifetime 10 ms. What's its saturation intensity?

Write units the way you normally would: 1.5 W/cm², 1500 mW/cm² and 0.0015 kW/cm² are the same answer.

Check

A medium with small-signal gain coefficient 0.01 cm⁻¹ is 10 cm long. What's its small-signal gain?

Check

An amplifier with 30 dB small-signal gain has a 5 mW saturation power. What's its output power at 3 dB gain compression?

Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.

Check

A 915 nm pump amplifies a 1064 nm signal. What's the largest possible power conversion efficiency?

Check

A high-gain optical amplifier has spontaneous-emission factor nsp = 1.4. What's its noise figure?

Check

A medium's small-signal gain coefficient is 0.01 cm⁻¹. At an intensity 0.5 times the saturation intensity, what is it?

Check

A gain medium at 1550 nm has a cross section of 7 × 10⁻²¹ cm² and an upper-level lifetime of 0.23 ms; it fills an 80 µm² core.

(a)

What is its saturation intensity?

Write units the way you normally would: 1.5 kW/cm^2, 1500 W/cm^2 and 0.0015 MW/cm^2 are the same answer.

(b)

What saturation power does the core give?

Check

An amplifier has small-signal gain coefficient g over length L, with population factor nsp = n.

Step 1

What is its small-signal gain in dB?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does an optical amplifier have a noise figure of at least 3 dB even when perfectly inverted?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.