title: Laser amplifiers
heading: Pumping to inversion, small-signal gain, gain saturation and the saturation intensity, the large-signal gain of a homogeneously broadened amplifier and its 3 dB compression point, the erbium-doped fiber amplifier, quantum-defect efficiency, and the noise figure set by spontaneous emission
eyebrow: S13 · Lesson 26 · Laser amplifiers
xp: 50
---

::: hook
Before 1990 every few tens of kilometers of fiber needed a repeater that detected the light, cleaned up the electrical signal and sent it again. The erbium-doped fiber amplifier changed that: a few meters of doped fiber, pumped by a semiconductor laser, amplifies every wavelength channel at once, by a factor of a thousand, directly as light. Its behavior comes down to how gain falls as the signal grows strong enough to use up the inversion, and to the noise that spontaneous emission inevitably adds.
:::

::: play
- A homogeneously broadened amplifier with small-signal gain $G_0$ and saturation power $P_\text{sat}$: the input power at which the gain has dropped to G, from $\ln(G_0/G) = (G - 1)P_\text{in}/P_\text{sat}$ (both axes logarithmic, in dB and dBm).
- For weak inputs the gain stays at $G_0$; around $P_\text{sat}/G_0$ at the input, it begins to compress.
- A strong signal leaves less inversion for itself: output power grows more slowly than input, approaching a ceiling set by the pump.
:::

```sim plot
view: graph
x: g = 0.5..40 dB
y: p = -50..20 dBm
slider: G = 15..40 step 0.5 = 30 dB
slider: s = 1..100 step 1 = 10 mW
plot: 10*log(s*ln(10^(G/10)/10^(g/10))/(10^(g/10) - 1)) | samples: 400 | label: input power giving gain g
readout: input at 3 dB compression, dBm = 10*log(s*ln(2)/(10^(G/10)/2 - 1)) | digits: 3
readout: output at 3 dB compression, mW = s*ln(2)*10^(G/10)/(10^(G/10) - 2) | digits: 3
```

::: predict
## An amplifier has 30 dB of small-signal gain and a 10 mW saturation power. What's its gain for a 100 µW input?

- [ ] 30 dB
- [ ] 27 dB
- [x] About 22 dB
- [ ] 10 dB

::: reveal
Solving $\ln(1000/G) = (G - 1) \times 0.1/10$ gives G = 175, 22.4 dB: the output, 17.5 mW, is well above the saturation power, so the signal itself has depleted much of the inversion. A 1 µW input sees 29.6 dB and a 1 mW input only 15.4 dB.
:::
:::

::: nameit
## Small-signal gain

A pumped medium with gain coefficient $\gamma_0$ over length L amplifies weak signals by $G_0 = e^{\gamma_0L}$, or $4.343\gamma_0L$ dB.

## Saturation

Stimulated emission by the signal drains the inversion. For a homogeneously broadened medium,

$$\gamma = \frac{\gamma_0}{1 + I/I_\text{sat}}, \qquad I_\text{sat} = \frac{h\nu}{\sigma\tau}$$

with τ the upper level's lifetime. Integrating through the amplifier, with $P_\text{sat} = I_\text{sat}A$,

$$\ln\frac{G_0}{G} = (G - 1)\frac{P_\text{in}}{P_\text{sat}}$$

The gain falls to half (3 dB compression) at an output power of $P_\text{sat}\ln 2\,\frac{G_0}{G_0 - 2}$.

## The erbium-doped fiber amplifier

Er³⁺ in silica, pumped at 980 or 1480 nm, amplifies across 1530 to 1565 nm (the C band). Its long lifetime (about 10 ms) means saturation responds only to average power, so it doesn't distort fast data. Signal photons can never outnumber pump photons, so the power conversion efficiency is at most the **quantum defect** ratio $\lambda_p/\lambda_s$.

## Noise

Spontaneous emission amplified along the fiber (ASE) adds noise. At high gain the noise figure is $F \approx 2n_\text{sp}$, with $n_\text{sp} = N_2/(N_2 - N_1) \ge 1$: at least 3 dB, the quantum limit for a phase-insensitive amplifier.
:::

::: example
## Find the saturation intensities of Nd:YAG (σ = 2.8 × 10⁻¹⁹ cm², τ = 230 µs, 1064 nm) and erbium (σ ≈ 7 × 10⁻²¹ cm², τ = 10 ms, 1550 nm).

::: solution
1. **Nd:YAG.**
   $$\begin{aligned} I_s &= \frac{h\nu}{\sigma\tau} \\ &= \frac{1.87 \times 10^{-19}\ \text{J}}{2.8 \times 10^{-23}\ \text{m}^2 \times 230\ \mu\text{s}} \\ &= 2.9\ \text{kW/cm}^2 \end{aligned}$$
2. **Erbium.**
   $$\begin{aligned} I_s &= \frac{1.28 \times 10^{-19}\ \text{J}}{7 \times 10^{-25}\ \text{m}^2 \times 10\ \text{ms}} \\ &= 1.8\ \text{kW/cm}^2 \end{aligned}$$
3. **In a fiber core.** In a core of 50 µm² that's about 1 mW for erbium, which is why EDFAs saturate at milliwatt powers.

**Answer:** the saturation intensity is 2.9 kW/cm² for Nd:YAG and 1.8 kW/cm² for erbium.
:::
:::

::: example
## For the 30 dB, 10 mW amplifier, where is the 3 dB compression point? And what's the best efficiency of a 980 nm pumped EDFA at 1550 nm?

::: solution
1. **Output at 3 dB compression.** There the gain has fallen from 1000 to 500, so
   $$\begin{aligned} P_\text{out} &= P_\text{sat}\ln 2 \times \frac{1000}{998} \\ &= 6.95\ \text{mW} \end{aligned}$$
   from an input of 13.9 µW.
2. **Quantum defect.**
   $$\frac{980}{1550} = 0.632$$
   so at most 63% of pump power becomes signal.
3. **Pumping at 1480 nm.** It raises the limit to 95%, at the cost of a noisier, less complete inversion.

**Answer:** the 3 dB compression point is at 6.95 mW of output (13.9 µW in), and a 980 nm pumped EDFA can turn at most 63% of its pump power into signal.
:::
:::

::: example
## The 30 dB amplifier with $P_\text{sat}$ = 10 mW receives 100 µW. How much gain does it actually give, and what comes out?

::: solution
1. **The saturated gain equation.**
   $$\ln\frac{1000}{G} = (G - 1) \times \frac{100\ \mu\text{W}}{10\ \text{mW}}$$
2. **Solve it.** Bisection gives G = 175, or 22.4 dB.
3. **Output.**
   $$175 \times 100\ \mu\text{W} = 17.5\ \text{mW}$$
   rather than the 100 mW the small-signal gain would promise.
4. **Why links run saturated.** Saturation trades gain for output power: EDFAs in long-haul links run deep in saturation on purpose, which makes their output nearly independent of input and keeps a chain of them stable.

**Answer:** the amplifier gives a gain of 175 (22.4 dB), and 17.5 mW comes out.
:::
:::

::: check
given: l = 0.8 | 1.064 | 1.55; s = 0.5 | 3 | 30; t = 0.01 | 0.23 | 10
answer: 6.62607015e-34*299792458/(l*1e-6)/(s*1e-23*t*1e-3)/1e4
unit: W/cm²
tolerance: 0.5%

## A transition at {l} µm has cross section {s} × 10⁻¹⁹ cm² and lifetime {t} ms. What's its saturation intensity?

::: right
Right. $h\nu/\sigma\tau$ = {answer} W/cm².
:::

::: misses
- [any] Not yet. Photon energy over cross section times lifetime.
:::
:::

::: check
given: g = 0.002 | 0.01 | 0.05; L = 10 | 50 | 200
answer: 10*log(exp(g*L))
unit: dB
tolerance: 0.5%

## A medium with small-signal gain coefficient {g} cm⁻¹ is {L} cm long. What's its small-signal gain?

::: right
Right. $4.343\gamma_0L$ = {answer} dB.
:::

::: misses
- [g*L] That's in nepers.
- [any] Not yet. $G_0 = e^{\gamma_0L}$.
:::
:::

::: check
given: G = 20 | 30 | 40; s = 5 | 20 | 100
answer: s*ln(2)*10^(G/10)/(10^(G/10) - 2)
unit: mW
tolerance: 0.5%

## An amplifier with {G} dB small-signal gain has a {s} mW saturation power. What's its output power at 3 dB gain compression?

::: right
Right. $P_\text{sat}\ln 2\,\frac{G_0}{G_0 - 2}$ = {answer} mW.
:::

::: misses
- [s] Compression to half gain happens at $P_\text{sat}\ln 2$, not $P_\text{sat}$.
- [any] Not yet. Set $G = G_0/2$ in the saturation equation.
:::
:::

::: check
given: p = 808 | 915 | 980; s = 1064 | 1550
answer: p/s
tolerance: 0.5%

## A {p} nm pump amplifies a {s} nm signal. What's the largest possible power conversion efficiency?

::: right
Right. $\lambda_p/\lambda_s$ = {answer}.
:::

::: misses
- [s/p] Each pump photon yields at most one signal photon of lower energy.
- [any] Not yet. The quantum defect.
:::
:::

::: check
given: n = 1 | 1.4 | 2
answer: 10*log(2*n)
unit: dB
tolerance: 0.5%

## A high-gain optical amplifier has spontaneous-emission factor $n_\text{sp}$ = {n}. What's its noise figure?

::: right
Right. $10\log_{10}(2n_\text{sp})$ = {answer} dB.
:::

::: misses
- [10*log(n)] The high-gain limit is $2n_\text{sp}$, at least 3 dB.
- [any] Not yet. $F \approx 2n_\text{sp}$.
:::
:::

::: check
given: g = 0.01 | 0.05; r = 0.5 | 2 | 10
answer: g/(1 + r)
unit: cm^-1
tolerance: 0.5%

## A medium's small-signal gain coefficient is {g} cm⁻¹. At an intensity {r} times the saturation intensity, what is it?

::: right
Right. $\gamma_0/(1 + I/I_\text{sat})$ = {answer} cm⁻¹.
:::

::: misses
- [g*exp(-r)] Homogeneous saturation follows $1/(1 + I/I_\text{sat})$.
- [any] Not yet. Saturation of the inversion.
:::
:::

::: check
kind: parts
given: s = 3 | 7 | 28; t = 0.23 | 1 | 10; l = 980 | 1064 | 1550; A = 10 | 50 | 80

## A gain medium at {l} nm has a cross section of {s} × 10⁻²¹ cm² and an upper-level lifetime of {t} ms; it fills a {A} µm² core.

::: part
answer: 6.62607015e-34*299792458/(l*1e-9)/(s*1e-25*t*1e-3)/1e7
unit: kW/cm^2
tolerance: 0.5%

### What is its saturation intensity?

::: misses
- [any] $h\nu/(\sigma\tau)$.
:::
:::

::: part
answer: 6.62607015e-34*299792458/(l*1e-9)/(s*1e-25*t*1e-3)*A*1e-12*1e3
unit: mW
tolerance: 0.5%

### What saturation power does the core give?

::: misses
- [any] $I_\text{sat}A$.
:::
:::
:::

::: check
kind: derivation
vars: g = 0.0001..1, L = 0.1..100, n = 1..5

## An amplifier has small-signal gain coefficient g over length L, with population factor $n_\text{sp}$ = n.

::: step
answer: 4.343*g*L

### What is its small-signal gain in dB?
:::

::: step
answer: 10*log(2*n)

### What is its high-gain noise figure in dB?
:::

::: right
Right. Full inversion ($n_\text{sp}$ = 1) gives the 3 dB quantum limit.
:::
:::

::: explain
## Why does an optical amplifier have a noise figure of at least 3 dB even when perfectly inverted?

::: model
An amplifier with gain G must also emit spontaneously: the same excited atoms that provide stimulated emission decay on their own at a rate tied to it, and those spontaneous photons, amplified along with the signal, add random noise. Even with all atoms inverted, the added noise referred to the input amounts to about one photon per mode, the same as the signal's own shot noise. Since the output then carries the amplified input noise plus an equal amount of spontaneous emission, the signal-to-noise ratio is halved: a 3 dB noise figure. Incomplete inversion adds absorption from the lower level, which raises it further. Only phase-sensitive amplifiers, which amplify one quadrature and squeeze the other, can avoid it.
:::
:::

::: practice

::: check
given: G = 15 | 45; s = 1 | 200
answer: s*ln(2)*10^(G/10)/(10^(G/10) - 2)
unit: mW
tolerance: 0.5%

## 3 dB compression output: {G} dB, {s} mW?

::: misses
- [any] $P_\text{sat}\ln 2\,G_0/(G_0 - 2)$.
:::
:::

::: check
given: p = 790 | 1000; s = 1030 | 2100
answer: p/s
tolerance: 0.5%

## Quantum-defect limit: {p} nm pump, {s} nm signal?

::: misses
- [any] $\lambda_p/\lambda_s$.
:::
:::

::: check
given: n = 1 | 1.1 | 1.3 | 1.5 | 2 | 3
answer: 10*log(2*n)
unit: dB
tolerance: 0.5%

## Noise figure: $n_\text{sp}$ = {n}?

::: misses
- [any] $10\log(2n_\text{sp})$.
:::
:::
:::