S13 · Lesson 29 · Laser linewidth and noise
Why a laser's frequency wanders, the Lorentzian linewidth and the coherence time and length it implies, measuring it by delayed self-heterodyne, relative intensity noise and the signal-to-noise ratio it allows, and the linewidths coherent links can tolerate
Lesson 28 treated a laser's output as a clean sinusoid at one frequency. It isn't quite: every spontaneously emitted photon that joins the lasing mode nudges its phase a little, so the phase random-walks and the spectrum has a width. In a DFB laser that width is a few megahertz; in a stabilized laser for an optical clock, under a hertz. The intensity flickers too. Both set limits: on interferometers' reach, on coherent receivers' formats, and on the signal-to-noise ratio of every analog optical link.
- The curve is a Lorentzian line shape, normalized to its peak, against frequency offset from the line center, for the full width at half maximum on the slider (in MHz).
- A random walk of phase with a constant diffusion rate gives exactly this shape.
- Its wings fall only as the square of the offset, so a Lorentzian line has more power far from center than a Gaussian of the same width.
Predict
A DFB laser has a 1 MHz Lorentzian linewidth. Over what path difference can it still make high-contrast interference fringes?
For a Lorentzian line the coherence time is = 318 ns, and the coherence length = 95 m, the path difference at which fringe visibility falls to 1/e. A 1 kHz fiber laser stretches that to 95 km, which is why such lasers serve fiber sensors and long interferometers.
Name it
Phase noise and linewidth
Spontaneous emission into the lasing mode adds randomly phased photons, so the optical phase diffuses. With a constant diffusion rate the spectrum is a Lorentzian of full width Δν, and the field's coherence decays as . The fundamental (Schawlow–Townes) linewidth falls in inverse proportion to the output power and grows with the cavity's loss; semiconductor lasers are broadened further by a factor , where Henry's α factor (3 to 6) couples gain and index.
Coherence
For a Lorentzian line:
Measuring linewidth
Beating the laser against a copy of itself delayed by more than several coherence times and frequency-shifted (delayed self-heterodyne) gives a Lorentzian of twice the laser's width, since two uncorrelated copies' phase noises add. The delay fiber must be several long.
Intensity noise
Relative intensity noise (RIN) is the spectral density of the power fluctuations divided by the square of the mean power, in dB/Hz. Over a detection bandwidth B, RIN alone limits the electrical signal-to-noise ratio to
for a fully modulated signal (RIN as a linear ratio per hertz).
Linewidth in coherent links
A coherent receiver must track the carrier's phase. For QPSK the combined linewidth of transmitter and local oscillator should stay below about of the symbol rate: 3.2 MHz at 32 GBd, easy for DFB lasers, while 64-QAM needs lasers ten times narrower.
Worked example
Find the coherence time and length of lasers with 1 MHz, 100 kHz and 1 kHz Lorentzian linewidths.
Show the solution
- Coherence times. gives 318 ns, 3.18 µs and 318 µs.
- Coherence lengths. gives 95 m, 954 m and 95 km.
- Use in lidar. The echo must still be coherent with the outgoing light when it returns. A target 1 km away means a 2 km round trip, about twice the 100 kHz laser's coherence length, so a coherent lidar at that range needs the 1 kHz laser.
Answer 318 ns and 95 m at 1 MHz, 3.18 µs and 954 m at 100 kHz, and 318 µs and 95 km at 1 kHz.
Worked example
How long a fiber delay (n = 1.468) does a delayed self-heterodyne measurement of a 100 kHz laser need, if the delay must be six coherence times?
Show the solution
- Six coherence times.
- Fiber length. Light travels = 204 m per microsecond in the fiber, so the delay line is
- The beat note. It's 200 kHz wide, twice the laser's linewidth.
- Narrower lasers. They need impractically long delays, so they're measured against a reference cavity or a second, independent laser instead.
Answer the delay needs about 3.9 km of fiber.
Worked example
A laser with a RIN of −150 dB/Hz drives an analog link with 10 GHz of bandwidth. What signal-to-noise ratio does its intensity noise allow?
Show the solution
- RIN as a ratio. −150 dB/Hz is
- Noise over the bandwidth. of the signal power, so SNR = 50 dB.
- Is that enough? For a cable-television or radio-over-fiber link needing 50 to 60 dB, that leaves no margin, and such links use lasers with RIN of −155 dB/Hz or better.
Answer the laser's intensity noise allows an SNR of 50 dB.
Check
A laser has a Lorentzian linewidth of 1 kHz.
(a)
What is its coherence time?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
(b)
What is its coherence length?
Check
A laser's relative intensity noise is −150 dB/Hz, detected over 0.1 GHz.
(a)
What signal-to-noise ratio does it allow?
Check
A delayed self-heterodyne setup measures a laser of 100 kHz linewidth with a delay of 5 coherence times in fiber of index 1.468.
(a)
How long is the delay fiber?
Write units the way you normally would: 1.5 km and 1500 m are the same answer.
(b)
How wide is the beat note?
Check
A coherent receiver runs at 32 GBd and tolerates a combined linewidth of 1 × 10⁻⁴ of the symbol rate.
(a)
What combined linewidth can its lasers have?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
Check
A semiconductor laser's linewidth is 2 MHz, with a linewidth enhancement factor α = 3.
(a)
What would its linewidth be without the α factor's broadening?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
Why does a laser's linewidth narrow as its output power rises?
Check
A laser has Lorentzian linewidth w and relative intensity noise R dB/Hz, detected over bandwidth B.
Step 1
What is its coherence length?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What signal-to-noise ratio in dB does its RIN allow?
Check
Write phase_walk(dnu, T, dt, n, seed): simulate n independent random walks of a laser's phase (each step a Gaussian of variance ) for time T, and return the average of over the walks, which should approach ; and coherence_length(dnu).
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
How can a laser that oscillates at a single frequency still have a measurable linewidth?
A laser's output is the stimulated emission of one cavity mode, but spontaneous emission keeps adding a few photons to that mode with random phases. Each one shifts the phase of the total field by a tiny random amount, so over time the phase wanders in a random walk while the amplitude stays nearly constant. A wave whose phase drifts randomly is no longer a pure sinusoid: its spectrum spreads into a Lorentzian whose width equals the rate of that phase diffusion. Lasers with more power in the mode, longer cavities, or lower loss diffuse more slowly and have narrower lines.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.