title: Laser linewidth and noise
heading: Why a laser's frequency wanders, the Lorentzian linewidth and the coherence time and length it implies, measuring it by delayed self-heterodyne, relative intensity noise and the signal-to-noise ratio it allows, and the linewidths coherent links can tolerate
eyebrow: S13 · Lesson 29 · Laser linewidth and noise
xp: 50
---

::: hook
Lesson 28 treated a laser's output as a clean sinusoid at one frequency. It isn't quite: every spontaneously emitted photon that joins the lasing mode nudges its phase a little, so the phase random-walks and the spectrum has a width. In a DFB laser that width is a few megahertz; in a stabilized laser for an optical clock, under a hertz. The intensity flickers too. Both set limits: on interferometers' reach, on coherent receivers' formats, and on the signal-to-noise ratio of every analog optical link.
:::

::: play
- The curve is a Lorentzian line shape, normalized to its peak, against frequency offset from the line center, for the full width at half maximum on the slider (in MHz).
- A random walk of phase with a constant diffusion rate gives exactly this shape.
- Its wings fall only as the square of the offset, so a Lorentzian line has more power far from center than a Gaussian of the same width.
:::

```sim plot
view: graph
x: f = -20..20
y: S = 0..1
slider: w = 0.1..10 = 2
plot: 1/(1 + (2*f/w)^2) | label: Lorentzian, normalized
plot: exp(-4*ln(2)*(f/w)^2) | dashed | label: Gaussian of the same width
```

::: predict
## A DFB laser has a 1 MHz Lorentzian linewidth. Over what path difference can it still make high-contrast interference fringes?

- [ ] About 1 mm
- [ ] About 1 m
- [x] Tens of meters (its coherence length is about 95 m)
- [ ] Hundreds of kilometers

::: reveal
For a Lorentzian line the coherence time is $\tau_c = 1/(\pi\Delta\nu)$ = 318 ns, and the coherence length $c\tau_c$ = 95 m, the path difference at which fringe visibility falls to 1/e. A 1 kHz fiber laser stretches that to 95 km, which is why such lasers serve fiber sensors and long interferometers.
:::
:::

::: nameit
## Phase noise and linewidth

Spontaneous emission into the lasing mode adds randomly phased photons, so the optical phase diffuses. With a constant diffusion rate the spectrum is a **Lorentzian** of full width Δν, and the field's coherence decays as $e^{-\pi\Delta\nu|\tau|}$. The fundamental (Schawlow–Townes) linewidth falls in inverse proportion to the output power and grows with the cavity's loss; semiconductor lasers are broadened further by a factor $1 + \alpha^2$, where Henry's α factor (3 to 6) couples gain and index.

## Coherence

For a Lorentzian line:
$$\tau_c = \frac{1}{\pi\Delta\nu}, \qquad l_c = \frac{c}{\pi\Delta\nu}$$

## Measuring linewidth

Beating the laser against a copy of itself delayed by more than several coherence times and frequency-shifted (delayed self-heterodyne) gives a Lorentzian of twice the laser's width, since two uncorrelated copies' phase noises add. The delay fiber must be several $l_c/n$ long.

## Intensity noise

**Relative intensity noise** (RIN) is the spectral density of the power fluctuations divided by the square of the mean power, in dB/Hz. Over a detection bandwidth B, RIN alone limits the electrical signal-to-noise ratio to
$$\text{SNR} = \frac{1}{\text{RIN}\cdot B}$$
for a fully modulated signal (RIN as a linear ratio per hertz).

## Linewidth in coherent links

A coherent receiver must track the carrier's phase. For QPSK the combined linewidth of transmitter and local oscillator should stay below about $10^{-4}$ of the symbol rate: 3.2 MHz at 32 GBd, easy for DFB lasers, while 64-QAM needs lasers ten times narrower.
:::

::: example
## Find the coherence time and length of lasers with 1 MHz, 100 kHz and 1 kHz Lorentzian linewidths.

::: solution
1. **Coherence times.**
   $$\tau_c = \frac{1}{\pi\Delta\nu}$$
   gives 318 ns, 3.18 µs and 318 µs.
2. **Coherence lengths.**
   $$l_c = c\tau_c$$
   gives 95 m, 954 m and 95 km.
3. **Use in lidar.** The echo must still be coherent with the outgoing light when it returns. A target 1 km away means a 2 km round trip, about twice the 100 kHz laser's coherence length, so a coherent lidar at that range needs the 1 kHz laser.

**Answer:** 318 ns and 95 m at 1 MHz, 3.18 µs and 954 m at 100 kHz, and 318 µs and 95 km at 1 kHz.
:::
:::

::: example
## How long a fiber delay (n = 1.468) does a delayed self-heterodyne measurement of a 100 kHz laser need, if the delay must be six coherence times?

::: solution
1. **Six coherence times.**
   $$\begin{aligned} 6\tau_c &= \frac{6}{\pi \times 100\ \text{kHz}} \\ &= 19.1\ \mu\text{s} \end{aligned}$$
2. **Fiber length.** Light travels $c/n$ = 204 m per microsecond in the fiber, so the delay line is
   $$19.1 \times 204\ \text{m} = 3.9\ \text{km}$$
3. **The beat note.** It's 200 kHz wide, twice the laser's linewidth.
4. **Narrower lasers.** They need impractically long delays, so they're measured against a reference cavity or a second, independent laser instead.

**Answer:** the delay needs about 3.9 km of fiber.
:::
:::

::: example
## A laser with a RIN of −150 dB/Hz drives an analog link with 10 GHz of bandwidth. What signal-to-noise ratio does its intensity noise allow?

::: solution
1. **RIN as a ratio.** −150 dB/Hz is
   $$10^{-15}\ \text{per hertz}$$
2. **Noise over the bandwidth.**
   $$10^{-15} \times 10^{10}\ \text{Hz} = 10^{-5}$$
   of the signal power, so SNR = 50 dB.
3. **Is that enough?** For a cable-television or radio-over-fiber link needing 50 to 60 dB, that leaves no margin, and such links use lasers with RIN of −155 dB/Hz or better.

**Answer:** the laser's intensity noise allows an SNR of 50 dB.
:::
:::

::: check
kind: parts
given: w = 0.01 | 1 | 100 | 5000

## A laser has a Lorentzian linewidth of {w} kHz.

::: part
answer: 1/(pi*w*1e3)*1e6
unit: µs
tolerance: 0.5%

### What is its coherence time?

::: misses
- [1/(w*1e3)*1e6] For a Lorentzian, $1/(\pi\Delta\nu)$.
- [any] $1/(\pi\Delta\nu)$.
:::
:::

::: part
answer: 299792458/(pi*w*1e3)
unit: m
tolerance: 0.5%

### What is its coherence length?

::: misses
- [any] $c/(\pi\Delta\nu)$.
:::
:::
:::

::: check
kind: parts
given: R = -140 | -150 | -160; B = 0.1 | 1 | 10

## A laser's relative intensity noise is {R} dB/Hz, detected over {B} GHz.

::: part
answer: -(R + 10*log(B*1e9))
unit: dB
tolerance: 0.5%

### What signal-to-noise ratio does it allow?

::: misses
- [-R] Integrate over the bandwidth.
- [any] $-(\text{RIN}_\text{dB} + 10\log B)$.
:::
:::
:::

::: check
kind: parts
given: w = 10 | 100 | 1000; k = 5 | 10

## A delayed self-heterodyne setup measures a laser of {w} kHz linewidth with a delay of {k} coherence times in fiber of index 1.468.

::: part
answer: k/(pi*w*1e3)*299792458/1.468/1e3
unit: km
tolerance: 0.5%

### How long is the delay fiber?

::: misses
- [any] $k\tau_c \cdot c/n$.
:::
:::

::: part
answer: 2*w
unit: kHz
tolerance: 0.5%

### How wide is the beat note?

::: misses
- [w] Two uncorrelated copies' phase noises add.
- [any] Twice the laser's linewidth.
:::
:::
:::

::: check
kind: parts
given: S = 8 | 32 | 64 | 96; k = 1 | 0.1

## A coherent receiver runs at {S} GBd and tolerates a combined linewidth of {k} × 10⁻⁴ of the symbol rate.

::: part
answer: S*1e9*k*1e-4/1e6
unit: MHz
tolerance: 0.5%

### What combined linewidth can its lasers have?

::: misses
- [any] The fraction times the symbol rate.
:::
:::
:::

::: check
kind: parts
given: w = 0.5 | 2 | 8; a = 3 | 5

## A semiconductor laser's linewidth is {w} MHz, with a linewidth enhancement factor α = {a}.

::: part
answer: w/(1 + a^2)*1e3
unit: kHz
tolerance: 0.5%

### What would its linewidth be without the α factor's broadening?

::: misses
- [w/a*1e3] The broadening factor is $1 + \alpha^2$.
- [any] Divide by $1 + \alpha^2$.
:::
:::
:::

::: check
kind: choice

## Why does a laser's linewidth narrow as its output power rises?

- [ ] The cavity gets longer
- [x] The phase is pushed around by spontaneous photons joining the mode at a nearly fixed rate; with more stimulated photons in the mode, each random photon moves the total field's phase less, so the phase diffuses more slowly
- [ ] Higher power cools the laser
- [ ] The gain bandwidth narrows

::: misses
- [1] The cavity is unchanged.
- [3] Higher power usually heats it.
- [4] The gain bandwidth isn't what sets the linewidth above threshold.
:::
:::

::: check
kind: derivation
vars: w = 1..100000000, R = -170..-110, B = 1000..100000000000

## A laser has Lorentzian linewidth w and relative intensity noise R dB/Hz, detected over bandwidth B.

::: step
answer: 299792458/(pi*w)

### What is its coherence length?
:::

::: step
answer: -(R + 10*log(B))

### What signal-to-noise ratio in dB does its RIN allow?
:::

::: right
Right. Linewidth limits coherent reach; RIN limits analog signal quality.
:::
:::

::: check
kind: python

## Write `phase_walk(dnu, T, dt, n, seed)`: simulate n independent random walks of a laser's phase (each step a Gaussian of variance $2\pi\Delta\nu\,dt$) for time T, and return the average of $\cos(\phi(T) - \phi(0))$ over the walks, which should approach $e^{-\pi\Delta\nu T}$; and `coherence_length(dnu)`.

```python starter
def phase_walk(dnu, T, dt, n, seed):
    return 1.0

def coherence_length(dnu):
    return 0.0
```

```python solution
import math, random

def phase_walk(dnu, T, dt, n, seed):
    rnd = random.Random(seed)
    sd = math.sqrt(2 * math.pi * dnu * dt)
    steps = int(round(T / dt))
    total = 0.0
    for _ in range(n):
        phi = 0.0
        for _ in range(steps):
            phi += rnd.gauss(0, sd)
        total += math.cos(phi)
    return total / n

def coherence_length(dnu):
    return 299792458 / (math.pi * dnu)
```

```python tests
import math
g = phase_walk(1e6, 318e-9, 2e-9, 4000, 1)
assert abs(g - math.exp(-1)) < 0.03, "After one coherence time the coherence has fallen to about 1/e."
assert abs(phase_walk(1e6, 30e-9, 1e-9, 2000, 2) - math.exp(-math.pi * 1e6 * 30e-9)) < 0.02, "A short delay keeps it near 1."
assert abs(coherence_length(1e6) - 95.4) < 0.1, "1 MHz: 95 m."
```

::: right
Right. A random walk of phase is all it takes to produce a Lorentzian line and an exponential loss of coherence.
:::
:::

::: explain
## How can a laser that oscillates at a single frequency still have a measurable linewidth?

::: model
A laser's output is the stimulated emission of one cavity mode, but spontaneous emission keeps adding a few photons to that mode with random phases. Each one shifts the phase of the total field by a tiny random amount, so over time the phase wanders in a random walk while the amplitude stays nearly constant. A wave whose phase drifts randomly is no longer a pure sinusoid: its spectrum spreads into a Lorentzian whose width equals the rate of that phase diffusion. Lasers with more power in the mode, longer cavities, or lower loss diffuse more slowly and have narrower lines.
:::
:::

::: practice
::: check
given: w = 0.5 | 50 | 2000
answer: 299792458/(pi*w*1e3)
unit: m
tolerance: 0.5%

## Coherence length at {w} kHz linewidth?

::: misses
- [any] $c/(\pi\Delta\nu)$.
:::
:::

::: check
given: R = -145 | -155; B = 0.5 | 5
answer: -(R + 10*log(B*1e9))
unit: dB
tolerance: 0.5%

## SNR from RIN {R} dB/Hz over {B} GHz?

::: misses
- [any] $-(\text{RIN} + 10\log B)$.
:::
:::

::: check
given: S = 16 | 64; k = 1 | 0.2
answer: S*1e9*k*1e-4/1e6
unit: MHz
tolerance: 0.5%

## Tolerable linewidth: {S} GBd, {k} × 10⁻⁴?

::: misses
- [any] Fraction times symbol rate.
:::
:::
:::