S13 · Lesson 28 · Lasers
Gain inside a resonator, the threshold condition and threshold inversion, the cavity photon lifetime, output power above threshold and slope efficiency, choosing the output coupler, and how many longitudinal modes fit under the gain curve
Put lesson 26's amplifier inside lesson 18's resonator and feedback does the rest. Spontaneous emission seeds the cavity, the round trip amplifies it, and if the gain beats the losses the light grows until saturation pins the gain exactly at the loss. That balance, the threshold condition, sets how hard the laser must be pumped, how much power it delivers above that, and how much of it can be extracted through the output mirror.
- Output power against pump power for a laser with 2% round-trip internal loss and an output coupler that transmits T. Below threshold there's no laser output; above it the output grows linearly with the slope efficiency.
- A larger T raises the threshold (more loss to overcome) but extracts a larger share of the light (steeper slope). At a given pump power there's a best T.
- The readout gives the optimum for 10 W of pump.
Predict
A 10 cm laser cavity has a perfect mirror, a 98% output mirror and 0.001 cm⁻¹ of distributed loss. What gain coefficient does the medium need to reach threshold?
At threshold the round-trip gain balances the round-trip loss: = 0.001 + (1/20 cm) × ln(1/0.98) = 0.001 + 0.00101 = 0.00201 cm⁻¹. The mirror's 2% and the medium's own loss contribute about equally.
Name it
Threshold
A wave making a round trip (length 2d) through a medium with gain γ and loss , reflecting off mirrors and , must return at least as strong as it started:
The threshold inversion is .
Photon lifetime
Light in the cavity decays at the rate (in a medium of index 1), so
the round-trip time divided by the fractional loss per round trip.
Above threshold
Saturation clamps the gain at ; extra pump power goes into stimulated emission. The output rises linearly, . Of the light generated, the output coupler takes the fraction , with the other round-trip losses; but a larger T also raises the threshold. For a threshold proportional to the total loss, , the best coupling at pump is .
Longitudinal modes
The laser oscillates on cavity modes spaced by wherever the gain exceeds the loss. A gain bandwidth Δν holds about of them.
Worked example
For the 10 cm cavity above, find the photon lifetime, and the threshold inversion if σ = 2.8 × 10⁻¹⁹ cm².
Show the solution
- Round-trip loss.
- Photon lifetime. The round trip takes 0.667 ns, so
- Threshold inversion. a few percent of the neodymium ions in a typical YAG rod.
Answer the photon lifetime is 16.6 ns, and the threshold inversion is 7.2 × 10¹⁵ cm⁻³.
Worked example
The laser in the sim (2% internal loss, threshold 50 W per unit of loss, 60% conversion) has 10 W of pump. Compare a 5% output coupler with the best one.
Show the solution
- Threshold at T = 5%.
- Slope.
- Output at 10 W of pump.
- The best coupler. giving 2.81 W.
- What that shows. The curve is flat near its peak, so a coupler within a percent or so of the optimum costs little.
Answer the 5% coupler gives 2.79 W, and the best one, 4.3%, gives 2.81 W.
Worked example
How many longitudinal modes can oscillate in a 10 cm Nd:YAG laser (gain width about 120 GHz) and in a 30 cm helium–neon laser (1.5 GHz)?
Show the solution
- Nd:YAG mode spacing. Taking the index as 1, as in the threshold example, the 10 cm cavity's modes are apart.
- Modes under the Nd:YAG line. and several dozen can run at once in a free-running laser.
- The HeNe laser. Its 500 MHz spacing fits only about three under its 1.5 GHz Doppler line.
- Getting one frequency. Single-frequency operation needs either a short cavity, an etalon, or a ring cavity that avoids spatial hole burning.
Answer about 80 longitudinal modes fit under the Nd:YAG gain curve, and about three under the HeNe's.
Check
A 5 cm cavity has one perfect mirror and one of reflectance 0.99, with distributed loss 0.001 cm⁻¹. What threshold gain coefficient does it need?
Check
A gain medium 120 GHz wide sits in a 5 cm air-spaced cavity. About how many longitudinal modes fit under it?
Check
A laser has threshold 0.5 W and slope efficiency 0.4. What does it emit at 50 W of pump?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A laser's output coupler transmits 0.05 per round trip and its other losses total 0.005. What fraction of the generated light leaves as output?
Check
A laser needs a threshold gain of 0.02 cm⁻¹ from a transition with cross section 0.5 × 10⁻¹⁹ cm². What inversion is that?
Check
A 10 cm cavity has one perfect mirror, one of reflectance 0.9, and distributed loss 0.002 cm⁻¹. What's its photon lifetime?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
A laser cavity 10 cm long has 0.001 cm⁻¹ of internal loss, one perfect mirror and an output coupler of reflectance 0.99; its gain medium has σ = 28 × 10⁻²⁰ cm².
(a)
What gain coefficient does it need to reach threshold?
(b)
What is its photon lifetime?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
(c)
What inversion does threshold need?
Check
A laser has internal loss L and an output coupler T; its threshold is k watts per unit of loss and its conversion efficiency e, pumped with P watts.
Step 1
What is its threshold pump power?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What output power does it give?
Explain why
Why does a laser's gain stay fixed at its threshold value however hard it's pumped?
Below threshold, pumping builds up the inversion and the gain rises. Once the round-trip gain exceeds the round-trip loss, the light in the cavity grows on every pass, and the growing light drains the inversion by stimulated emission. The light can only stop growing when the gain has been pulled back down to exactly the loss; if the gain fell below the loss the light would decay and the inversion would recover. So in steady state the gain is pinned at threshold, and any extra pump power, rather than raising the inversion further, is converted into more stimulated emission: more photons in the cavity and more output. That's why output rises linearly above threshold.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.