Absorption, spontaneous and stimulated emission between two levels, the transition cross section and its relation to the spontaneous lifetime, homogeneous (Lorentzian) and inhomogeneous (Doppler) line broadening, population inversion and the gain coefficient

B10 introduced Einstein's A and B coefficients for atoms in thermal equilibrium. To build amplifiers and lasers we need the same physics in engineering form: how strongly an atom interacts with light at each frequency (its cross section and lineshape), and how a population of excited atoms turns that into gain per centimeter. The numbers differ by orders of magnitude between a helium–neon tube, an erbium-doped fiber and a Nd:YAG rod, and those differences decide how each device is built.

  • Two normalized lineshapes with the same full width at half maximum Δν: a Lorentzian (homogeneous broadening, from the excited state's finite lifetime or collisions) and a Gaussian (inhomogeneous, from atoms moving at different speeds).
  • With the same width, the Gaussian has a higher peak (0.939/Δν against 0.637/Δν) and much weaker wings.
  • The cross section, and so the gain, at each frequency is proportional to the lineshape.

Predict

The neon atoms in a helium–neon laser (mass 20 u) run at about 400 K. How wide is their 632.8 nm line from Doppler broadening?

Name it

Three processes

Between a lower level 1 and upper level 2, separated by hν0:

  • absorption and stimulated emission, at rates proportional to the photon flux and to the cross section σ(ν), with stimulated photons identical to the stimulating ones;
  • spontaneous emission, at rate 1/tsp per excited atom.

Cross section and lineshape

σ(ν)=λ28πn2tspg(ν)

with g(ν) the normalized lineshape (∫g dν = 1) and λ the free-space wavelength.

  • Homogeneous (every atom identical): Lorentzian, g(ν)=Δν/2π(ν−ν0)2+(Δν/2)2, peak 2/(πΔν). Lifetime alone gives Δν=1/(2πτ).
  • Inhomogeneous (atoms differ, as in Doppler shifts or glass hosts): Gaussian, peak 2ln⁡2/π/Δν, with Doppler width ΔνD=ν08kTln⁡2/Mc2.

Gain

With population densities N1 and N2 (equal degeneracies), a beam grows as eγz with

γ(ν)=(N2−N1)σ(ν)

Gain needs population inversion, N2>N1, which thermal equilibrium never provides; it must be pumped.

Worked example

Estimate the peak cross sections of erbium in silica at 1550 nm (tsp = 10 ms, n = 1.45, Δν ≈ 4 THz) and of Nd:YAG at 1064 nm (tsp = 230 µs, n = 1.82, Δν ≈ 120 GHz), treating both lines as Lorentzian.

Show the solution
  1. Erbium. σ=λ28πn2tsp×2πΔν=7.2×10−21cm2 close to measured values.
  2. Nd:YAG. The same formula gives 3.1×10−18 cm², about eleven times its measured 2.8×10−19 cm².
  3. Why Nd:YAG comes out high. The upper level's 230 µs lifetime is shared among several transitions and Stark sublevels, so the 1064 nm line's own radiative rate is much slower than 1/tsp.
  4. What erbium's numbers mean. Erbium's long lifetime and broad line make its cross section small, so fiber amplifiers need long lengths; the same long lifetime stores energy well.

Answer about 7.2 × 10⁻²¹ cm² for erbium and 3.1 × 10⁻¹⁸ cm² for Nd:YAG, the second eleven times the measured value.

Worked example

A Nd:YAG rod has an inversion of 10¹⁷ cm⁻³ with σ = 2.8 × 10⁻¹⁹ cm². What's its gain over 10 cm?

Show the solution
  1. Gain coefficient. γ=1017×2.8×10−19=0.028cm−1
  2. Single-pass gain over 10 cm. G=e0.028×10=e0.28=1.32 or 1.22 dB.
  3. What it's good for. It's enough to overcome a few percent of mirror loss in a laser, but small for an amplifier, which is why solid-state amplifiers use several passes.

Answer the rod gives a single-pass gain of 1.32, or 1.22 dB.

Worked example

Find the Doppler width of the neon line in a helium–neon laser (632.8 nm, neon of mass 20 u at about 400 K), and how many longitudinal modes of a 30 cm cavity fall under it.

Show the solution
  1. Line frequency. ν0=c632.8nm=473.8THz
  2. Doppler width. ΔνD=ν08kTln⁡2Mc2=1.52GHz far wider than the natural width of the transition.
  3. Mode spacing. A 30 cm cavity's modes are c2d=500MHz apart.
  4. Modes under the line. About three fit under the gain curve, which is why an ordinary HeNe laser runs on two or three frequencies unless its cavity is short or it carries a mode-selecting etalon.

Answer the Doppler width is 1.52 GHz, and about three longitudinal modes of the 30 cm cavity fall under it.

Check

An excited state lives 0.01 µs. What's its natural linewidth?

Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.

Check

Atoms of mass 133 u at 300 K emit at 632.8 nm. How wide is the Doppler-broadened line?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

Check

A medium has an inversion of 10 × 10¹⁶ cm⁻³ and cross section 0.1 × 10⁻²⁰ cm². What's its gain coefficient?

Check

A beam crosses 5 cm of a medium with gain coefficient 0.05 cm⁻¹. What's the gain in dB?

Check

A transition at 1.064 µm has tsp = 0.1 ms in a host of index 1.82, with a Lorentzian line 5 THz wide. What's its peak cross section?

Check

For the same full width (2 GHz), how many times taller is a Gaussian lineshape's peak than a Lorentzian's?

Check

A transition at 0.5 µm in a medium of index 1.8 has a spontaneous lifetime of 1 µs and only lifetime broadening.

(a)

What is its linewidth?

Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.

(b)

What is its peak cross section?

Check

A medium has upper and lower populations a and b per cm³, cross section s cm², and length L cm.

Step 1

What is its gain coefficient per cm?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why can't a medium in thermal equilibrium amplify light?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.