title: "Light and matter: lineshapes, cross sections and gain"
heading: Absorption, spontaneous and stimulated emission between two levels, the transition cross section and its relation to the spontaneous lifetime, homogeneous (Lorentzian) and inhomogeneous (Doppler) line broadening, population inversion and the gain coefficient
eyebrow: S13 · Lesson 25 · Light and matter: lineshapes, cross sections and gain
xp: 50
---

::: hook
B10 introduced Einstein's A and B coefficients for atoms in thermal equilibrium. To build amplifiers and lasers we need the same physics in engineering form: how strongly an atom interacts with light at each frequency (its cross section and lineshape), and how a population of excited atoms turns that into gain per centimeter. The numbers differ by orders of magnitude between a helium–neon tube, an erbium-doped fiber and a Nd:YAG rod, and those differences decide how each device is built.
:::

::: play
- Two normalized lineshapes with the same full width at half maximum Δν: a Lorentzian (homogeneous broadening, from the excited state's finite lifetime or collisions) and a Gaussian (inhomogeneous, from atoms moving at different speeds).
- With the same width, the Gaussian has a higher peak (0.939/Δν against 0.637/Δν) and much weaker wings.
- The cross section, and so the gain, at each frequency is proportional to the lineshape.
:::

```sim plot
view: graph
x: v = -3..3 GHz
y: g = 0..1.2 GHz^-1
slider: w = 0.2..2 step 0.05 = 1 GHz
plot: (w/(2*pi))/(v^2 + (w/2)^2) | samples: 600 | label: Lorentzian
plot: 2*sqrt(ln(2)/pi)/w*exp(-4*ln(2)*v^2/w^2) | samples: 600 | color: ch3 | label: Gaussian
readout: Lorentzian peak, 1/GHz = 2/(pi*w) | digits: 3
readout: Gaussian peak, 1/GHz = 2*sqrt(ln(2)/pi)/w | digits: 3
```

::: predict
## The neon atoms in a helium–neon laser (mass 20 u) run at about 400 K. How wide is their 632.8 nm line from Doppler broadening?

- [ ] About 16 MHz
- [ ] About 150 MHz
- [x] About 1.5 GHz
- [ ] About 150 GHz

::: reveal
Atoms moving toward or away from the observer shift the frequency by v/c. With thermal velocities at 400 K, $\Delta\nu_D = \nu_0\sqrt{8kT\ln 2/(Mc^2)}$ = 473.8 THz × 3.2 × 10⁻⁶ = 1.52 GHz, about a hundred times the natural width set by the excited state's lifetime.
:::
:::

::: nameit
## Three processes

Between a lower level 1 and upper level 2, separated by $h\nu_0$:

- **absorption** and **stimulated emission**, at rates proportional to the photon flux and to the cross section $\sigma(\nu)$, with stimulated photons identical to the stimulating ones;
- **spontaneous emission**, at rate $1/t_\text{sp}$ per excited atom.

## Cross section and lineshape

$$\sigma(\nu) = \frac{\lambda^2}{8\pi n^2t_\text{sp}}g(\nu)$$

with $g(\nu)$ the normalized lineshape (∫g dν = 1) and λ the free-space wavelength.

- **Homogeneous** (every atom identical): Lorentzian, $g(\nu) = \frac{\Delta\nu/2\pi}{(\nu - \nu_0)^2 + (\Delta\nu/2)^2}$, peak $2/(\pi\Delta\nu)$. Lifetime alone gives $\Delta\nu = 1/(2\pi\tau)$.
- **Inhomogeneous** (atoms differ, as in Doppler shifts or glass hosts): Gaussian, peak $2\sqrt{\ln 2/\pi}/\Delta\nu$, with Doppler width $\Delta\nu_D = \nu_0\sqrt{8kT\ln 2/Mc^2}$.

## Gain

With population densities $N_1$ and $N_2$ (equal degeneracies), a beam grows as $e^{\gamma z}$ with

$$\gamma(\nu) = (N_2 - N_1)\sigma(\nu)$$

Gain needs **population inversion**, $N_2 > N_1$, which thermal equilibrium never provides; it must be pumped.
:::

::: example
## Estimate the peak cross sections of erbium in silica at 1550 nm ($t_\text{sp}$ = 10 ms, n = 1.45, Δν ≈ 4 THz) and of Nd:YAG at 1064 nm ($t_\text{sp}$ = 230 µs, n = 1.82, Δν ≈ 120 GHz), treating both lines as Lorentzian.

::: solution
1. **Erbium.**
   $$\begin{aligned} \sigma &= \frac{\lambda^2}{8\pi n^2t_\text{sp}} \times \frac{2}{\pi\Delta\nu} \\ &= 7.2 \times 10^{-21}\ \text{cm}^2 \end{aligned}$$
   close to measured values.
2. **Nd:YAG.** The same formula gives $3.1 \times 10^{-18}$ cm², about eleven times its measured $2.8 \times 10^{-19}$ cm².
3. **Why Nd:YAG comes out high.** The upper level's 230 µs lifetime is shared among several transitions and Stark sublevels, so the 1064 nm line's own radiative rate is much slower than $1/t_\text{sp}$.
4. **What erbium's numbers mean.** Erbium's long lifetime and broad line make its cross section small, so fiber amplifiers need long lengths; the same long lifetime stores energy well.

**Answer:** about 7.2 × 10⁻²¹ cm² for erbium and 3.1 × 10⁻¹⁸ cm² for Nd:YAG, the second eleven times the measured value.
:::
:::

::: example
## A Nd:YAG rod has an inversion of 10¹⁷ cm⁻³ with σ = 2.8 × 10⁻¹⁹ cm². What's its gain over 10 cm?

::: solution
1. **Gain coefficient.**
   $$\begin{aligned} \gamma &= 10^{17} \times 2.8 \times 10^{-19} \\ &= 0.028\ \text{cm}^{-1} \end{aligned}$$
2. **Single-pass gain over 10 cm.**
   $$\begin{aligned} G &= e^{0.028 \times 10} \\ &= e^{0.28} \\ &= 1.32 \end{aligned}$$
   or 1.22 dB.
3. **What it's good for.** It's enough to overcome a few percent of mirror loss in a laser, but small for an amplifier, which is why solid-state amplifiers use several passes.

**Answer:** the rod gives a single-pass gain of 1.32, or 1.22 dB.
:::
:::

::: example
## Find the Doppler width of the neon line in a helium–neon laser (632.8 nm, neon of mass 20 u at about 400 K), and how many longitudinal modes of a 30 cm cavity fall under it.

::: solution
1. **Line frequency.**
   $$\begin{aligned} \nu_0 &= \frac{c}{632.8\ \text{nm}} \\ &= 473.8\ \text{THz} \end{aligned}$$
2. **Doppler width.**
   $$\begin{aligned} \Delta\nu_D &= \nu_0\sqrt{\frac{8kT\ln 2}{Mc^2}} \\ &= 1.52\ \text{GHz} \end{aligned}$$
   far wider than the natural width of the transition.
3. **Mode spacing.** A 30 cm cavity's modes are
   $$\frac{c}{2d} = 500\ \text{MHz}$$
   apart.
4. **Modes under the line.** About three fit under the gain curve, which is why an ordinary HeNe laser runs on two or three frequencies unless its cavity is short or it carries a mode-selecting etalon.

**Answer:** the Doppler width is 1.52 GHz, and about three longitudinal modes of the 30 cm cavity fall under it.
:::
:::

::: check
given: t = 0.001 | 0.01 | 10 | 1000
answer: 1/(2*pi*t*1e-6)/1e6
unit: MHz
tolerance: 0.5%

## An excited state lives {t} µs. What's its natural linewidth?

::: right
Right. $1/(2\pi\tau)$ = {answer} MHz.
:::

::: misses
- [1/(t*1e-6)/1e6] Include 2π.
- [any] Not yet. The Fourier width of an exponential decay.
:::
:::

::: check
given: l = 488 | 632.8 | 1064; T = 300 | 400 | 1000; M = 20 | 40 | 133
answer: 299792458/(l*1e-9)*sqrt(8*1.380649e-23*T*ln(2)/(M*1.66053907e-27*299792458^2))/1e9
unit: GHz
tolerance: 0.5%

## Atoms of mass {M} u at {T} K emit at {l} nm. How wide is the Doppler-broadened line?

::: right
Right. $\nu_0\sqrt{8kT\ln 2/Mc^2}$ = {answer} GHz.
:::

::: misses
- [any] Not yet. Thermal velocity spread times $\nu_0/c$.
:::
:::

::: check
given: N = 1 | 10 | 100; s = 0.1 | 3 | 50
answer: N*1e16*s*1e-20
unit: cm^-1
tolerance: 0.5%

## A medium has an inversion of {N} × 10¹⁶ cm⁻³ and cross section {s} × 10⁻²⁰ cm². What's its gain coefficient?

::: right
Right. $(N_2 - N_1)\sigma$ = {answer} cm⁻¹.
:::

::: misses
- [any] Not yet. $\gamma = N\sigma$.
:::
:::

::: check
given: g = 0.01 | 0.05 | 0.3; L = 5 | 20 | 100
answer: 10*log(exp(g*L))
unit: dB
tolerance: 0.5%

## A beam crosses {L} cm of a medium with gain coefficient {g} cm⁻¹. What's the gain in dB?

::: right
Right. $10\log_{10}e^{\gamma L}$ = {answer} dB.
:::

::: misses
- [10*g*L] Convert nepers to decibels: 4.343 dB per unit of γL.
- [any] Not yet. $G = e^{\gamma L}$, then dB.
:::
:::

::: check
given: l = 0.98 | 1.064 | 1.55; t = 0.1 | 1 | 10; n = 1.45 | 1.82; w = 0.1 | 1 | 5
answer: (l*1e-6)^2/(8*pi*n^2*t*1e-3)*2/(pi*w*1e12)*1e4
unit: cm²
tolerance: 0.5%

## A transition at {l} µm has $t_\text{sp}$ = {t} ms in a host of index {n}, with a Lorentzian line {w} THz wide. What's its peak cross section?

::: right
Right. $\frac{\lambda^2}{8\pi n^2t_\text{sp}}\cdot\frac{2}{\pi\Delta\nu}$ = {answer} cm².
:::

::: misses
- [any] Not yet. Cross section from lifetime and lineshape.
:::
:::

::: check
given: w = 0.5 | 2 | 10
answer: 2*sqrt(ln(2)/pi)/w/(2/(pi*w))
tolerance: 0.5%

## For the same full width ({w} GHz), how many times taller is a Gaussian lineshape's peak than a Lorentzian's?

::: right
Right. $\sqrt{\pi\ln 2}$ = {answer}, independent of the width.
:::

::: misses
- [any] Not yet. Compare $2\sqrt{\ln 2/\pi}/\Delta\nu$ with $2/\pi\Delta\nu$.
:::
:::

::: check
kind: parts
given: t = 0.01 | 1 | 100; l = 0.5 | 1 | 1.55; n = 1 | 1.5 | 1.8

## A transition at {l} µm in a medium of index {n} has a spontaneous lifetime of {t} µs and only lifetime broadening.

::: part
answer: 1/(2*pi*t*1e-6)/1e3
unit: kHz
tolerance: 0.5%

### What is its linewidth?

::: misses
- [1/(t*1e-6)/1e3] Divide by 2π.
- [any] $1/(2\pi\tau)$.
:::
:::

::: part
answer: (l*1e-4)^2/(8*pi*n^2*t*1e-6)*2/(pi*1/(2*pi*t*1e-6))
unit: cm^2
tolerance: 0.5%

### What is its peak cross section?

::: misses
- [any] $\lambda^2/(8\pi n^2t_\text{sp})$ times the Lorentzian's peak $2/(\pi\Delta\nu)$.
:::
:::
:::

::: check
kind: derivation
vars: a = 1000000000000000..10000000000000000000, b = 0..1000000000000000000, s = 0.0000000000000000000001..0.000000000000000001, L = 0.01..100

## A medium has upper and lower populations a and b per cm³, cross section s cm², and length L cm.

::: step
answer: (a - b)*s

### What is its gain coefficient per cm?
:::

::: step
answer: 4.343*(a - b)*s*L

### What is its single-pass gain in dB?
:::

::: right
Right. Gain needs inversion; its size is inversion times cross section.
:::
:::

::: explain
## Why can't a medium in thermal equilibrium amplify light?

::: model
In equilibrium the populations follow the Boltzmann distribution, $N_2/N_1 = e^{-h\nu/kT}$, always less than one. Stimulated emission and absorption have the same cross section for a given pair of levels, so a beam passing through loses photons to absorption by the lower level faster than it gains them from stimulated emission by the upper one: the net gain coefficient $(N_2 - N_1)\sigma$ is negative. At optical frequencies $h\nu \gg kT$, so $N_2$ is negligible and the medium simply absorbs. Amplification needs more atoms in the upper level than the lower, a population inversion, which has to be created and maintained by pumping energy in from outside.
:::
:::

::: practice

::: check
given: t = 0.0005 | 0.016 | 0.026 | 1 | 230 | 5000
answer: 1/(2*pi*t*1e-6)/1e6
unit: MHz
tolerance: 0.5%

## Natural width: τ = {t} µs?

::: misses
- [any] $1/2\pi\tau$.
:::
:::

::: check
given: N = 0.5 | 500; s = 0.05 | 100
answer: N*1e16*s*1e-20
unit: cm^-1
tolerance: 0.5%

## Gain coefficient: {N} × 10¹⁶ cm⁻³, {s} × 10⁻²⁰ cm²?

::: misses
- [any] $N\sigma$.
:::
:::

::: check
given: g = 0.005 | 0.2; L = 1 | 50
answer: 10*log(exp(g*L))
unit: dB
tolerance: 0.5%

## Gain: γ = {g} cm⁻¹, L = {L} cm?

::: misses
- [any] $4.343\gamma L$.
:::
:::
:::