S13 · Lesson 6 · Interferometric sensors
Measuring rotation, displacement and strain with the phase of light
Lesson 5 showed that two beams interfere according to the difference in their optical paths, with a fringe for every wavelength of difference. Turn that around and an interferometer becomes a ruler marked in fractions of a wavelength: the laser trackers that calibrate machine tools count fringes over meters; the fiber-optic gyroscopes in aircraft and spacecraft measure rotation through the Sagnac effect, a path difference that exists only because the instrument is turning; and gravitational-wave detectors resolve changes of m. The physics is a phase difference; the engineering is making it large enough and keeping everything else from changing it.
- The Sagnac phase shift of a fiber-optic gyroscope, , for a coil of total fiber length wound on diameter , at 1550 nm, against rotation rate in degrees per hour.
- Earth's rotation, 15°/h, gives microradians with a few hundred meters of fiber: a navigation-grade gyroscope must resolve phases a thousand times smaller still.
Predict
A Michelson interferometer with a 633 nm laser watches a mirror move 1 mm. How many fringes pass?
Moving the mirror by changes the round-trip path by , so each fringe is a move: = 3160 fringes. Counting them, and interpolating within a fringe, gives position to a few nanometers over meters, as long as the air's refractive index, which changes the wavelength, is known.
Name it
Displacement
In a Michelson or Mach-Zehnder interferometer, a change in one arm's optical path changes the phase by . With a mirror in a Michelson, , so each fringe is . Fringe counting needs two signals 90° apart (quadrature) to tell direction. The laser's coherence length, , must exceed the path difference, and the air's index (about 1.00027) must be corrected, about 270 ppm.
The Sagnac effect
Light sent both ways around a rotating loop takes slightly different times: the beam traveling with the rotation has farther to go. For a loop of area rotating at Ω, with turns of fiber,
with the total fiber length and the coil diameter. The effect is tiny: Earth's 7.3 × 10⁻⁵ rad/s gives microradians. A fiber-optic gyroscope gets its sensitivity from kilometers of fiber, and its stability from both beams sharing exactly the same path (reciprocity), so temperature and vibration affect them equally and cancel; a phase modulator biases the output to its most sensitive point.
Sensitivity and noise
An interferometer's output intensity is ; small changes are best seen at = 90° (quadrature), where the slope is largest. Shot noise sets the smallest detectable phase, about radians: more light, smaller phase.
Worked example
A fiber gyroscope has 1000 turns on an 8 cm coil, at 1550 nm. Find its fiber length and its Sagnac phase for Earth's rotation, and for 1°/h.
Show the solution
- Fiber length.
- Sagnac phase for Earth's rotation.
- At 1°/h. That's rad/s, so the phase is
- Navigation grade. Navigation gyros resolve 0.01°/h, about 10 nanoradians, which is why the output is averaged and the light source is a broadband one that keeps backscatter from interfering coherently.
Answer the coil holds 251 m of fiber, and its Sagnac phase is 19.8 µrad for Earth's rotation and 1.32 µrad for 1°/h.
Worked example
A displacement interferometer at 633 nm runs in air without index correction. What error results over 1 m of travel?
Show the solution
- Wavelength in air. The air's index is about 1.00027, so the wavelength in air is 270 ppm shorter than in vacuum.
- The error. Counting fringes as if in vacuum misreads 1 m by
- How real systems correct it. They measure air temperature, pressure and humidity and correct to better than 1 ppm.
Answer without correction, 1 m of travel reads 270 µm wrong.
Worked example
A Mach-Zehnder strain sensor has 1 m of fiber in its sensing arm. Strain ε changes the arm's optical length by about with = 1.45. What phase change does 1 µε cause at 1550 nm?
Show the solution
- Change in optical length.
- Phase change.
- The practical challenge. Interferometric fiber sensors are so sensitive that their challenge is rejecting temperature, which changes the path by a similar amount per degree, usually with a reference arm in the same environment.
Answer 1 µε shifts the phase by 4.6 rad.
Check
A Michelson interferometer at 532 nm watches its mirror move 1 mm. How many fringes pass?
Check
A fiber gyroscope has 1000 turns on a 4 cm coil at 1550 nm. What Sagnac phase does 100°/h of rotation produce?
Write units the way you normally would: 1.5 µrad and 0.0015 mrad are the same answer.
Check
Air's refractive index exceeds 1 by 270 ppm. Without index correction, how far off is a vacuum-wavelength fringe count over 0.5 m of travel?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
Check
A laser has a linewidth of 10 MHz. What is its coherence length, , in cm?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Check
At its shot-noise limit, an interferometer detects about radians with photons. What is that for N = 1 × 10¹⁰?
Write units the way you normally would: 1.5 µrad and 0.0015 mrad are the same answer.
Check
Why does a fiber-optic gyroscope send light both ways around the same coil instead of comparing the coil with a separate reference fiber?
Check
Count fringes with quadrature. A mirror moves from 0 to d = 3.3 µm at constant speed, observed at 633 nm by two detectors with signals and , , sampled 20 000 times, plus Gaussian noise of RMS noise = 0.01 (numpy.random.default_rng(5), cosine noise first). Recover the displacement by unwrapping the angle numpy.arctan2(s, c) and converting back. Set x_est (µm) and err (nm).
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
A machine-shop laser interferometer reads 3 µm differently on a warm afternoon than in the morning, over the same 1 m of a granite table that hasn't moved. Explain why, and how such instruments stay accurate.
The interferometer measures distance in units of the laser's wavelength in air, which depends on the air's refractive index, about 1.00027; the index falls by roughly 1 ppm per degree Celsius of temperature rise and changes with pressure and humidity. Over 1 m, a 3 °C change shifts the index by about 3 ppm, 3 µm of apparent length, with nothing moving. The granite itself also expands a few ppm per degree. Accurate instruments measure the air's temperature, pressure and humidity along the beam and correct the wavelength with the Edlén equation, and measure the workpiece's temperature to correct its expansion to the 20 °C reference; the best systems work in vacuum or use a reference interferometer of fixed length.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.